background image

22

8.3 Disposal

The add-on drive, its battery pack and accessories are durable products. 
They might however contain substances that are hazardous to the environment, 
if the parts are disposed of in locations (e.g. landfills) that are not destined for 
the disposal of such materials according to the applicable statutory regulations.
The product is labelled in accordance with European Directive 2002/96/EC (WEEE Direc-
tive) with a crossed-out waste bin symbol, reminding you that it must be recycled.
Please take care of the environment and return the product at the end of its service 
life to your local recycling centre. 
As this product is not covered by the regulations of the WEEE Directive in all European 
countries, please inform yourself of the applicable waste disposal regulations in your 
country. In Germany, the product is for example classified as a transport vehicle and 
is thus not covered by the Electrical and Electronic Equipment Act implementing the 
WEEE Directive.
Alternatively, return the product to your authorised specialist dealer or Alber 
representative for proper and safe disposal.

8.4 Re-use 

If your viaplus has been provided to you by your health insurance company and you 
do not need it any longer, please contact your health insurer, Alber representative or 
authorised specialist dealer, as your add-on drive can be given to somebody else. 
Before re-using the viaplus, its safety must be checked. The brackets with which 
the viaplus is attached to the wheelchair can be easily and quickly removed by the 
authorised dealer or Alber representative and mounted on another.
Before re-using the viaplus, clean it as described in chapter 8.2 and disinfect the 
control unit [9] and the housing of the battery pack [18]. To do this, use a product 
based on isopropyl alcohol that is suitable for wiping disinfection. The product must 
have an alcohol concentration of 70 %. Observe the use instructions of the product. 

8.5 Maintenance

Your viaplus is a low-maintenance device. You should nevertheless check all attach-
ment and accessory parts at regular intervals to ensure that these parts are firmly 
seated.
At least every 2 years, you must have your viaplus examined by an expert (technical 
safety inspection) to check its performance and safety. During such an inspection, 
damage and signs of wear and fatigue that are not visible to the eye and might occur 
during use of the system can be detected.
To arrange a safety inspection, contact your authorised specialist dealer or Alber  
representative.

GA-V12_GB.indd   22

26.05.2010   13:04:10

Summary of Contents for Viaplus

Page 1: ...Brems und Schiebehilfe Gebrauchsanweisung D User manual GB US Instructions d utilisation F Instruktionsbok S Damit Schieben einfach wird...

Page 2: ...Das viaplus ist klassifiziert als Ger t Typ B...

Page 3: ...1 2 3 4 5 6 7 8 9 10 12 13 14 16 17 15 18 19 20 18 21 11 25 22 23 24...

Page 4: ...rging battery pack through the viaplus 11 3 3 Changing fuse in battery pack 12 3 4 General battery information 12 4 Transport 13 4 1 Removing viaplus from wheelchair 13 4 2 Attaching viaplus to wheelc...

Page 5: ...e viaplus When in operation the viaplus might under certain circumstances interfere with other electrical equipment such as anti shoplifting barriers in department stores Therefore do not start the vi...

Page 6: ...g Control unit 0 3 kg Battery charger 0 5 kg Total weight 20 5 kg The range depends on the terrain and the prevailing driving conditions The specified maximum range is valid for optimum travel conditi...

Page 7: ...heel 7 Mounting fork 8 Control unit Control unit housing 9 Control button 10 LED status indicator 11 Driving lever 12 Plug 13 Battery pack Plug contact 14 Fuse 25 A 15 Hinged cover 16 Charger socket a...

Page 8: ...of the bracket 22 and all necessary adjustments to the viaplus must be carried out by Ulrich Alber GmbH its repre sentative or your authorised specialist dealer Regularly check the bracket 22 to ensur...

Page 9: ...hair by its handles Using the tip of your foot fold down the pedal 6 of the viaplus from its resting position When the pedal 6 is in its centre position push it down firmly with your foot to extend th...

Page 10: ...ied 2 4 Reverse travel Hold the viaplus with both hands by the handles of the wheelchair Push the driving lever 12 slowly up to the stop As long as the driving lever 12 is pushed up the viaplus drives...

Page 11: ...rive When driving along bends turning the wheelchair or driving uphill or downhill the centre of gravity of the wheelchair might be shifted so that there is a risk that the wheelchair might tip over t...

Page 12: ...ED status indicator 11 is constantly on Lift the wheelchair by its handles and pull it backwards over the obstacle After having traversed the obstacle Lower the drive wheels 7 again see chapter 2 1 Se...

Page 13: ...s resting position When the pedal 6 is in its centre position push it down firmly with your foot to retract the two lowered drive wheels 7 After the wheels 7 are fully retracted fold the pedal 6 up to...

Page 14: ...ns plug of the battery charger 20 from the mains socket Disconnect the plug 19 of the battery charger from the charger socket 17 of the battery pack Fold the hinged cover 16 up by 90 degrees and close...

Page 15: ...harge i e after every use of the device Lead batteries are subject to what is known as self discharge If the battery pack is not in use for a prolonged period of time without charging its capacity can...

Page 16: ...umb and index finger push together the two locking mechanisms on the plug 1 of the viaplus Disconnect the plug 1 from the socket 14 of the battery pack Remove the battery pack from the bag or box At t...

Page 17: ...viaplus into the mounting forks 24 of the bracket 22 The setting ring 5 attached to the bolt 4 must thereby be located inside the bracket 22 i e towards the centre of the wheelchair Press down the re...

Page 18: ...it a little At the rear of the battery pack housing 18 Place the battery pack in the bag or box and secure it with the Velcro strap Insert the plug 1 into the socket 14 of the battery pack Check whet...

Page 19: ...rage To store the viaplus place it on a surface that is easy to clean If you wish to store the viaplus for a prolonged period of time you must keep the device and in particular the battery pack in a d...

Page 20: ...the motor during downhill travel Switch the viaplus off and on again see chapter 2 2 2 6 Continue the downhill travel at the lowest possible speed If possible avoid prolonged steep descents while the...

Page 21: ...ed and all fuses are OK This defect can only be repaired at the factory your authorised specialist dealer or Alber representative the viaplus suddenly stops Switch the viaplus off and then on again If...

Page 22: ...ct button to the lowest speed and then gradually increase it to the desired walking speed The viaplus must not be used to drive on slopes of more than 10 Under no circumstance must the maximum permiss...

Page 23: ...to use the viaplus to drive along slopes of more than 10 The basic safety requirements include proper tyre profiles correct wheelchair tyre pressure firm ground and a maximum load of 120 kg on the wh...

Page 24: ...optimised contact pressure and safe drive behaviour If the profile and the side radiuses R are not visible any more the tyre of your viaplus is worn see figure B At this point the diameter X of the ty...

Page 25: ...you by your health insurance company and you do not need it any longer please contact your health insurer Alber representative or authorised specialist dealer as your add on drive can be given to som...

Page 26: ...ater force majeure and other events that are outside the control of Ulrich Alber GmbH parts that might need to be serviced or replaced as part of normal use e g replacement of tripped fuses change of...

Page 27: ...9 0 7432 2006 0 Telefax 49 0 7432 2006 299 info alber de www alber de Ihre Alber Vertretung Your Alber representative Votre repr sentation Alber Vostra rappresentanza Alber Su representaci n Alber Din...

Reviews: