8
7
6. Fault signals
6. LED status indicator continuously on
As a rule, the LED status indicator [11] is continuously on, if the viaplus is working properly.
If the battery pack is nearly empty, its residual capacity might under certain circumstances not be large enough to activate a flash
code. In this case, the LED status indicator remains continuously on until the battery pack is fully discharged. Recharge the battery.
6.2 LED status indicator flash codes
Faults in the operation of your viaplus are indicated by means of flash codes of the LED status indicator [11].
Codes:
LED flash code
Cause of problem
Remedy
(flashing 1x)
The battery pack of the viaplus is
discharged.
Recharge the battery pack as soon as
possible.
(flashing 3x)
The battery pack has been automatically
recharged to its full capacity by the motor
during downhill travel.
Switch the viaplus off and on again
(see chapter 2.2 / 2.6).
Continue the downhill travel at the lowest
possible speed.
If possible, avoid prolonged steep descents
while the battery pack is fully recharged.
(flashing 6x)
The locking device to prevent unintentio-
nal drive function activation has noticed
that you have actuated the driving lever
[12] while switching on the viaplus.
Release the driving lever [12] and switch
off the viaplus.
Then switch on the viaplus again without
actuating the driving lever [12].
(flashing 9x)
Internal error
Switch the viaplus off and on again
(see chapter 2.2 / 2.6).
If the error persists, the viaplus cannot
be used. Contact your authorised specia-
list dealer or Alber representative.
!
If one of the fault codes listed in the table above occurs, the electronic system of the viaplus has detected
a fault or defect in the device. In such a case, it is not possible to operate the add-on drive.
Contact your authorised specialist dealer or Alber representative.
GA-V12_GB.indd 17
26.05.2010 13:04:09