BYPASS CONTROL                                

CODE                      FUNCTION

5                          ZONE BYPASS 

ON

6                          ZONE BYPASS 

OFF

TO ENTER A SYSTEM CONTROL FUNCTION CODE

1. LOAD VALID FOUR DIGIT ACCESS CODE, THEN PRESS #,(POUND), KEY TO ENTER CODE
2. ENTER THE SELECTED FUNCTION CODE, THEN PRESS #,(POUND), KEY TO ENTER CODE

TO ENTER A BYPASS CONTROL FUNCTION CODE

1. LOAD VALID FOUR DIGIT ACCESS CODE, THEN PRESS #,(POUND), KEY TO ENTER CODE
2. LOAD SELECTED BYPASS FUNCTION CODE, THEN PRESS     ,(STAR). KEY TO ENTER
3. LOAD TWO DIGIT ZONE NUMBER,(01 - 32), THEN PRESS #,(POUND), KEY TO EXECUTE

NOTE: ONLY ONE ZONE AT A TIME CAN BE BYPASSED OR UN-BYPASSED

C. ANNUNCIATE RESET

THE AUDIBLE ANNUNCIATOR WILL SOUND WHEN A ZONE HAS BEEN VIOLATED OR A SYSTEM TROUBLE SIGNAL 

IS DETECTED.  NOTE: AFTER ACKNOWLEDGMENT OF THE ACTIVITY THE ANNUNCIATOR MUST BE RESET.

TO RESET THE AUDIBLE ANNUNCIATOR

1. ENTER VALID FOUR DIGIT ACCESS CODE, THEN PRESS 

#

,(POUND), KEY TO ENTER

2. PRESS KEY 1

3. PRESS 

,(POUND), KEY TO EXECUTE

THE AUDIBLE ANNUNCIATOR WILL BE SILENCED WHEN KEYS ARE PRESSED.  IF THE AUDIBLE ANNUNCIATOR IS NOT 

RESET, THE AUDIBLE SIGNAL WILL SOUND AFTER THE LAST KEY IS PRESSED.

D. MEMORY RESET

WHEN A ZONE HAS BEEN VIOLATED THE ZONE MEMORY IS SET.  IN ORDER TO MONITOR THE ZONE STATUS THE

ZONE MEMORY MUST BE RESET.

TO RESET THE ZONE MEMORY

1. ENTER A VALID FOUR DIGIT ACCESS CODE, THEN PRESS 

#

,(POUND),KEY TO ENTER

2. PRESS KEY 2
3. PRESS 

#

,(POUND), KEY TO EXECUTE

THE ZONE MEMORY WILL RESET, THE ZONE INDICATOR WILL TURN 

OFF 

UNLESS THE ZONE IS STILL VIOLATED.

E. DAY ZONE MODE

THE DAY ZONE MODE IS ACTIVE WHEN THE DAY ZONE STATUS INDICATOR IS 

ON.  

ALL DESIGNATED DAY ZONES

ARE BYPASSED WHEN THE DAY ZONE MODE IS ACTIVATED ALLOWING FREE ACCESS TO THOSE ZONES WITHOUT

CAUSING A VIOLATION.

TO ACTIVATE THE DAY ZONE MODE

1. ENTER VALID FOUR DIGIT ACCESS CODE, THEN PRESS 

#

,(POUND), KEY TO ENTER

2. PRESS 3 KEY
3. PRESS 

#

,(POUND), KEY TO EXECUTE

IF DAY ZONE MODE WAS 

OFF

DAY ZONE MODE WILL TURN 

ON.  

IF DAY ZONE MODE WAS 

ON 

DAY ZONE MODE WILL

TURN 

OFF.

NOTE: ALL DAY ZONES ARE BYPASSED WHEN THE DAY MODE IS 

ON.

F. SYSTEM TEST

IT IS RECOMMENDED THAT THE SYSTEM TEST BE OPERATED AT LEAST ONCE A WEEK TO CHECK ALL ZONE STATUS,

SYSTEM INDICATORS AND STAND-BY BATTERY CONDITION.

PAGE 2

*

Summary of Contents for ZAC-32

Page 1: ...A SYSTEM CONTROL CABINET CONNECTED TO CONSOLE WITH FOUR WIRE CABLE REMOTE CONSOLE CAN BE LOCATED UP TO 1000 FEET FROM CONTROL CABINET BUILT IN AUDIBLE SIGNAL SOUND LEVEL IS 80dB 3 FEET SIXTEEN FOUR DI...

Page 2: ...DUCTOR WIRE DESKTOP ANNUNCIATOR CONECTED TO CABINET WITH 22 GA SHEILDED 4 CONDUCTOR WIRE DESKTOP ANNUNCIATOR SIZE 16 2 L x 8 W x 2 8 D CABINET SIZE 13 H x 11 75 W x 3 5 D RACK MOUNTED ANNUNCIATOR STAN...

Page 3: ...MENTS 2 AC POWER 2 STANDBY BATTERY 2 EARTH GROUND 2 ZONE INPUTS ZAC 32 2 ZONE INPUTS ZAC 32S 3 ZONE TERMINAL DESIGNATIONS 3 CONNECTING PROCESSOR TO PRINTER INTERFACE 4 AUXILIARY VOLTAGE OUTPUTS 4 EXTE...

Page 4: ...NE PROCESSOR FROM THE REMOTE CONSOLE OVER A FOUR CONDUCTOR CABLE UP TO FOUR REMOTE CONSOLES CAN BE ADDED TO THE SYSTEM FOR ANNUNCIATION AND CONTROL AT MULTIPLE LOCATIONS REMOTE CONSOLES CAN BE LOCATED...

Page 5: ...HAVE STANDBY POWER IF FUSE IS BLOWN THE BATTERY FUSE IS LOCATED TO THE RIGHT OF TERMINAL 7 ON THE PRINTED CIRCUIT BOARD C EARTH GROUND THIS UNIT HAS EFFECTIVE LIGHTNING PROTECTION ONLY WHEN GROUNDED A...

Page 6: ...ATION 1 19 21 20 21 _ _ _ _ _ _ _ _ 17 43 45 44 45 _ _ _ _ _ _ _ _ 2 19 22 20 22 _ _ _ _ _ _ _ _ 18 43 46 44 46 _ _ _ _ _ _ _ _ 3 19 23 20 23 _ _ _ _ _ _ _ _ 19 43 47 44 47 _ _ _ _ _ _ _ _ 4 19 24 20...

Page 7: ...AXIMUM TOTAL CURRENT AVAILABLE FROM THESE OUTPUTS IS 700 MA THIS TOTAL OF ALL OUTPUTS SHOULD NOT BE EXCEEDED USE THE PROVIDED CHART TO TOTAL THE SUM OF THE OUTPUTS VOLTAGE OUTPUT TERMINALS CURRENT USE...

Page 8: ...CALCULATING THE TOTAL CURRENT USED BY THE SYSTEM THE REMOTE CONSOLE IS TERMINATED WITH AN EIGHT CONDUCTOR MODULAR CORD AN EIGHT CONDUCTOR MODULAR JACK IS SUPPLIED TO TERMINATE THE CABLE RUN BETWEEN TH...

Page 9: ...C 28 MA NOTE TOTAL CURRENT FROM ALL OUTPUTS NOT TO EXCEED 800 MA FUSES BATTERY FUSE 2 5 SB 3 AG AUXILIARY POWER FUSES 5 x 20MM 500MA ZONE PARAMETERS LOOP RESPONSE TIME 250 MS TO ACTIVATE 125 MS TO RE...

Page 10: ...PREPARED BY THE FEDERAL COMMUNICATION COMMISSION HELPFUL HOW TO IDENTIFY AND RESOLVE RADIO TV INTERFERENCE PROBLEMS THIS BOOKLET IS AVAILABLE FROM THE U S GOVERNMENT PRINTING OFFICE WASHINGTON DC 204...

Page 11: ......

Page 12: ...PLAY CONSOLE THE REMOTE CONSOLE DISPLAYS AND CONTROLS ZONE STATUS AND SYSTEM CONDITIONS THE CONSOLE CONTAINS A DIGITAL KEYPAD ZONE SYSTEM INDICATORS AND AN AUDIBLE SIGNAL A DIGITAL KEYPAD THE DIGITAL...

Page 13: ...THE AUDIBLE ANNUNCIATOR IS NOT RESET THE AUDIBLE SIGNAL WILL SOUND AFTER THE LAST KEY IS PRESSED D MEMORY RESET WHEN A ZONE HAS BEEN VIOLATED THE ZONE MEMORY IS SET IN ORDER TO MONITOR THE ZONE STATU...

Page 14: ...ZONE 2 INDICATOR WILL FLASH BYPASS STATUS OUTPUT WILL TURN ON THE FOLLOWING IS AN EXAMPLE OF THE ZONE UN BYPASS FUNCTION TO UN BYPASS ZONE NUMBER 30 1 LOAD A VALID FOUR DIGIT ACCESS CODE THEN PRESS PO...

Page 15: ...ODE 01 1865 02 9506 03 5198 04 7357 05 9274 06 4742 07 2645 08 2405 09 7928 10 9258 11 8296 12 8320 13 9078 14 9536 15 8878 16 4530 B ZONE DESIGNATIONS STANDARD ZONES 1 24 DAY ZONES 25 32 ALARM CONTRO...

Reviews: