MODEL ZAC-32 OPERATING INSTRUCTIONS

I.   INTRODUCTION

THE ZAC-32 ZONE ANNUNCIATOR/CONTROLLER IS A TWO COMPONENT SYSTEM COMPRISED OF A CENTRAL ZONE

PROCESSOR AND A REMOTE DISPLAY CONSOLE.  THE SYSTEM PROVIDES TOTAL ZONE MONITORING AND CONTROL  

AT THE FULL FEATURED REMOTE CONSOLE.  THE SYSTEM IS CAPABLE OF ZONE EXPANSION IN THIRTY-TWO ZONE

MULTIPLES.  THE REMOTE CONSOLE CONTROLS AND DISPLAYS ALL THIRTY-TWO ZONES.  THE CONDITION OF EACH 

ZONE IS CLEARLY DISPLAYED ON THE FUNCTIONALLY DESIGNED CONSOLE.   A DIGITAL KEYPAD IS USED TO ALLOW

AUTHORIZED  PERSONEL  ACCESS TO THE SYSTEM BY AN IDENTIFYING ACCESS CODE  AND TO PERFORM VARIOUS     

SYSTEM FUNCTIONS.

II.  THE ZONE PROCESSOR    

THE ZAC-32 HAS 32 ZONES.  EACH ZONE IS INDEPENDENT IN OPERATION.  WHEN A ZONE IS VIOLATED THE ZONE

INDICATOR AND THE AUDIBLE SIGNAL WILL TURN ON AND ZONE MEMORY WILL BE SET.  IF THE VIOLATED ZONE IS

RESTORED BEFORE IT IS ACKNOWLEDGED THE ZONE INDICATOR WILL REMAIN ON.

THE ZONE PROCESSOR CONTAINS A POWER SUPPLY AND RECHARGEABLE BACK-UP BATTERY.  THE AC POWER AND

BATTERY ARE MONITORED FOR FAILURE.  IF THE AC POWER IS INTERRUPTED OR THE BATTERY VOLTAGE DROPS

BELOW A SAFE LEVEL THE SYSTEM INDICATORS AND AUDIBLE SIGNAL WILL REPORT THE TROUBLE CONDITION.

WHEN AC POWER HAS BEEN RESTORED THE INDICATORS AND AUDIBLE SIGNAL WILL TURN OFF.

III.  THE REMOTE DISPLAY CONSOLE

THE REMOTE CONSOLE DISPLAYS AND CONTROLS ZONE STATUS AND SYSTEM CONDITIONS.  THE CONSOLE

CONTAINS A DIGITAL KEYPAD, ZONE SYSTEM INDICATORS AND AN AUDIBLE SIGNAL..

A. DIGITAL KEYPAD

- THE DIGITAL KEYPAD IS USED TO ACCESS AND CONTROL THE SYSTEM.

B. ZONE ANNUNCIATION

- THE ZONE INDICATORS DISPLAY COMPLETE ZONE STATUS.

FLASHING - ZONE BYPASSED, OFF -  ZONE SECURE OR IN A NON-VIOLATED CONDITION

ON - ZONE  VIOLATED OR IN ZONE MEMORY.

C. SYSTEM INDICATORS  

-  THE SYSTEM INDICATORS DISPLAY THE FOLLOWING INFORMATION.

DAY MODE INDICATOR ON - ALL DAY ZONES ARE BYPASSED.  ACCESS INDICATOR ON - A

VALID CODE HAS BEEN ENTERED.  LOW BATTERY INDICATOR ON - LOW BATTERY VOLTAGE

HAS BEEN DETECTED.  POWER FAILURE INDICATOR ON

AC POWER IS OFF.

D. ANNUNCIATOR 

-               AN AUDIBLE SIGNAL SOUNDS TO INDICATE A ZONE VIOLATION, SYSTEM TROUBLE OR

WHEN A KEY IS PRESSED.

IV.  ZONE ANNUNCIATION/CONTROLLER SYSTEM OPERATION

A. ACCESS CODE 

- A FOUR DIGIT ACCESS CODE MUST BE ENTERED BEFORE ANY FUNCTION CODE WILL BE ACCEPTED.

ALL  ACCESS CODES ARE PRESET AT THE FACTORY.  A LIST OF ACCESS CODES IS INCLUDED WITH      

EACH UNIT.  LISTED BELOW IS THE PROCEDURE FOR ENTERING AN ACCESS CODE.

1.

LOAD  A VALID FOUR DIGIT ACCESS CODE.  PRESS EACH NUMBER OF THE CODE UNTIL  A BEEP

IS HEARD.

2.

PRESS THE #,(POUND), KEY TO ENTER THE CODE.

3. 

ACCESS INDICATOR TURNS ON

NOTE: AFTER 60 SECONDS ACCESS IS AUTOMATICALLY TURNED OFF.

B. FUNCTION CODES - 

THE ZONE ANNUNCIATOR/CONTROLLER HAS SIX FUNCTIONS.

SYSTEM CONTROL                                
CODE                      FUNCTION

1                           ANNUNCIATION RESET
2                          ZONE MEMORY RESET
3                          DAY ZONE MODE
4                          SYSTEM TEST

PAGE 1

Summary of Contents for ZAC-32

Page 1: ...A SYSTEM CONTROL CABINET CONNECTED TO CONSOLE WITH FOUR WIRE CABLE REMOTE CONSOLE CAN BE LOCATED UP TO 1000 FEET FROM CONTROL CABINET BUILT IN AUDIBLE SIGNAL SOUND LEVEL IS 80dB 3 FEET SIXTEEN FOUR DI...

Page 2: ...DUCTOR WIRE DESKTOP ANNUNCIATOR CONECTED TO CABINET WITH 22 GA SHEILDED 4 CONDUCTOR WIRE DESKTOP ANNUNCIATOR SIZE 16 2 L x 8 W x 2 8 D CABINET SIZE 13 H x 11 75 W x 3 5 D RACK MOUNTED ANNUNCIATOR STAN...

Page 3: ...MENTS 2 AC POWER 2 STANDBY BATTERY 2 EARTH GROUND 2 ZONE INPUTS ZAC 32 2 ZONE INPUTS ZAC 32S 3 ZONE TERMINAL DESIGNATIONS 3 CONNECTING PROCESSOR TO PRINTER INTERFACE 4 AUXILIARY VOLTAGE OUTPUTS 4 EXTE...

Page 4: ...NE PROCESSOR FROM THE REMOTE CONSOLE OVER A FOUR CONDUCTOR CABLE UP TO FOUR REMOTE CONSOLES CAN BE ADDED TO THE SYSTEM FOR ANNUNCIATION AND CONTROL AT MULTIPLE LOCATIONS REMOTE CONSOLES CAN BE LOCATED...

Page 5: ...HAVE STANDBY POWER IF FUSE IS BLOWN THE BATTERY FUSE IS LOCATED TO THE RIGHT OF TERMINAL 7 ON THE PRINTED CIRCUIT BOARD C EARTH GROUND THIS UNIT HAS EFFECTIVE LIGHTNING PROTECTION ONLY WHEN GROUNDED A...

Page 6: ...ATION 1 19 21 20 21 _ _ _ _ _ _ _ _ 17 43 45 44 45 _ _ _ _ _ _ _ _ 2 19 22 20 22 _ _ _ _ _ _ _ _ 18 43 46 44 46 _ _ _ _ _ _ _ _ 3 19 23 20 23 _ _ _ _ _ _ _ _ 19 43 47 44 47 _ _ _ _ _ _ _ _ 4 19 24 20...

Page 7: ...AXIMUM TOTAL CURRENT AVAILABLE FROM THESE OUTPUTS IS 700 MA THIS TOTAL OF ALL OUTPUTS SHOULD NOT BE EXCEEDED USE THE PROVIDED CHART TO TOTAL THE SUM OF THE OUTPUTS VOLTAGE OUTPUT TERMINALS CURRENT USE...

Page 8: ...CALCULATING THE TOTAL CURRENT USED BY THE SYSTEM THE REMOTE CONSOLE IS TERMINATED WITH AN EIGHT CONDUCTOR MODULAR CORD AN EIGHT CONDUCTOR MODULAR JACK IS SUPPLIED TO TERMINATE THE CABLE RUN BETWEEN TH...

Page 9: ...C 28 MA NOTE TOTAL CURRENT FROM ALL OUTPUTS NOT TO EXCEED 800 MA FUSES BATTERY FUSE 2 5 SB 3 AG AUXILIARY POWER FUSES 5 x 20MM 500MA ZONE PARAMETERS LOOP RESPONSE TIME 250 MS TO ACTIVATE 125 MS TO RE...

Page 10: ...PREPARED BY THE FEDERAL COMMUNICATION COMMISSION HELPFUL HOW TO IDENTIFY AND RESOLVE RADIO TV INTERFERENCE PROBLEMS THIS BOOKLET IS AVAILABLE FROM THE U S GOVERNMENT PRINTING OFFICE WASHINGTON DC 204...

Page 11: ......

Page 12: ...PLAY CONSOLE THE REMOTE CONSOLE DISPLAYS AND CONTROLS ZONE STATUS AND SYSTEM CONDITIONS THE CONSOLE CONTAINS A DIGITAL KEYPAD ZONE SYSTEM INDICATORS AND AN AUDIBLE SIGNAL A DIGITAL KEYPAD THE DIGITAL...

Page 13: ...THE AUDIBLE ANNUNCIATOR IS NOT RESET THE AUDIBLE SIGNAL WILL SOUND AFTER THE LAST KEY IS PRESSED D MEMORY RESET WHEN A ZONE HAS BEEN VIOLATED THE ZONE MEMORY IS SET IN ORDER TO MONITOR THE ZONE STATU...

Page 14: ...ZONE 2 INDICATOR WILL FLASH BYPASS STATUS OUTPUT WILL TURN ON THE FOLLOWING IS AN EXAMPLE OF THE ZONE UN BYPASS FUNCTION TO UN BYPASS ZONE NUMBER 30 1 LOAD A VALID FOUR DIGIT ACCESS CODE THEN PRESS PO...

Page 15: ...ODE 01 1865 02 9506 03 5198 04 7357 05 9274 06 4742 07 2645 08 2405 09 7928 10 9258 11 8296 12 8320 13 9078 14 9536 15 8878 16 4530 B ZONE DESIGNATIONS STANDARD ZONES 1 24 DAY ZONES 25 32 ALARM CONTRO...

Reviews: