background image

 FCC 

COMPLIANCE 

 

THIS EQUIPMENT GENERATES AND USES RADIO FREQUENCY ENERGY AND IF NOT 
INSTALLED AND USED PROPERLY, THAT IS IN STRICT ACCORDANCE WITH THE 
MANUFACTURER’S INSTRUCTION, MAY CAUSE INTERFERENCE TO RADIO AND TELEVISION 
RECEPTION.  IT HAS BEEN TYPE TESTED AND FOUND TO COMPLY WITH THE LIMITS FOR A 
CLASS B COMPUTING DEVICE IN ACCORDANCE WITH THE SPECIFICATIONS OF SUBPART J 
OF PART 15 OF FCC RULES, WHICH ARE DESIGNED TO PROVIDE REASONABLE PROTECTION 
AGAINST SUCH INTERFERENCE IN AN INSTALLATION.  HOWEVER, THERE IS NO GUARANTEE 
THAT INTERFERENCE WILL NOT OCCUR IN A PARTICULAR INSTALLATION.  IF THIS 
EQUIPMENT DOES CAUSE INTERFERENCE TO RADIO OR TELEVISION RECEPTION, WHICH 
CAN BE DETERMINED BY TURNING THE EQUIPMENT OFF AND ON.  THE USER IS 
ENCOURAGED TO TRY TO CORRECT THE INTERFERENCE BY ONE OR MORE OF THE 
FOLLOWING MEASURES.  

 

 

 

1.  RE-ORIENT THE TV OR RADIO ANTENNA. 

 

 

 

 

2.  RELOCATE OR MOVE THE EQUIPMENT AWAY FROM THE RECEIVER.  

 

3.  PLUG THE TRANSFORMER FOR THE EQUIPMENT INTO A DIFFERENT OUTLET SO THAT 

THE RECEIVER AND THE EQUIPMENT ARE ON DIFFERENT BRANCH CIRCUITS. 

 
 

4.  IF NECESSARY, THE USER SHOULD CONSULT THE INSTALLER OR AN EXPERIENCED 

RADIO/ TELEVISION TECHNICAN FOR ADDITIONAL SUGGESTIONS.  THE USER MAY FIND 
THE FOLLOWING BOOKLET PREPARED BY THE FEDERAL COMMUNICATION COMMISSION 
HELPFUL: “HOW TO IDENTIFY AND RESOLVE RADIO/ TV INTERFERENCE PROBLEMS”. 
THIS BOOKLET IS AVAILABLE FROM THE U.S. GOVERNMENT PRINTING OFFICE, 
WASHINGTON, DC 20402, STOCK #004-000-00345-4. 

 

 

 WARRANTY 
 

 

THE EQUIPMENT MANUFACTURED BY ALARM CONTROLS CORPORATION IS GUARANTEED TO 
BE FREE FROM DEFECTS IN MATERIAL AND WORKMANSHIP UNDER NORMAL USE AND 
SERVICE WHEN INSTALLED IN ACCORDANCE WITH ALARM CONTROLS CORPORATION’S 
INSTALLATION INSTRUCTIONS. ALARM CONTROLS CORPORATION, WARRANTS TO REPLACE 
OR REPAIR, FREE OF CHARGE, THE EQUIPMENT COVERED BY THE WARRANTY WHICH HAS 
BEEN RETURNED TO THE FACTORY, TRANSPORTATION CHARGES PREPAID, WITHIN TWELVE 
MONTHS FROM RECEIPT OF THE EQUIPMENT AT ORIGINAL DESTINATION, AND WHICH, IN 
THE SOLE JUDGEMENT OF ALARM CONTROLS CORPORATION IS DEFECTIVE IN MATERIAL 
AND WORKMANSHIP. ANY MISUSE, MODIFICATION, REWORK, OR ADJUSTMENT ON 
EQUIPMENT BY ANY PERSON OTHER THAN AN AUTHORIZED REPRESENTATIVE OF ALARM 
CONTROLS CORPORATION SHALL VOID THE WARRANTY.  THIS WARRANTY IS LIMITED ONLY 
TO THOSE PRODUCTS MANUFACTURED BY ALARM CONTROLS CORPORATION. 

 

THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES EXPRESSED OR 
IMPLIED, INCLUDING THE WARRANTY OF MERCHANTABILITY AND FITNESS FOR ANY 
PARTICULAR PURPOSE OR USE, AND IN NO EVENT SHALL ALARM CONTROLS CORPORATION 
BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES AS SAME ARE DEFINED IN THE 
UNIFORM COMMERCIAL CODE. 
 
 
 
 
 
 
 
 
 
 
 

 

PAGE 7

 

Summary of Contents for ZAC-32

Page 1: ...A SYSTEM CONTROL CABINET CONNECTED TO CONSOLE WITH FOUR WIRE CABLE REMOTE CONSOLE CAN BE LOCATED UP TO 1000 FEET FROM CONTROL CABINET BUILT IN AUDIBLE SIGNAL SOUND LEVEL IS 80dB 3 FEET SIXTEEN FOUR DI...

Page 2: ...DUCTOR WIRE DESKTOP ANNUNCIATOR CONECTED TO CABINET WITH 22 GA SHEILDED 4 CONDUCTOR WIRE DESKTOP ANNUNCIATOR SIZE 16 2 L x 8 W x 2 8 D CABINET SIZE 13 H x 11 75 W x 3 5 D RACK MOUNTED ANNUNCIATOR STAN...

Page 3: ...MENTS 2 AC POWER 2 STANDBY BATTERY 2 EARTH GROUND 2 ZONE INPUTS ZAC 32 2 ZONE INPUTS ZAC 32S 3 ZONE TERMINAL DESIGNATIONS 3 CONNECTING PROCESSOR TO PRINTER INTERFACE 4 AUXILIARY VOLTAGE OUTPUTS 4 EXTE...

Page 4: ...NE PROCESSOR FROM THE REMOTE CONSOLE OVER A FOUR CONDUCTOR CABLE UP TO FOUR REMOTE CONSOLES CAN BE ADDED TO THE SYSTEM FOR ANNUNCIATION AND CONTROL AT MULTIPLE LOCATIONS REMOTE CONSOLES CAN BE LOCATED...

Page 5: ...HAVE STANDBY POWER IF FUSE IS BLOWN THE BATTERY FUSE IS LOCATED TO THE RIGHT OF TERMINAL 7 ON THE PRINTED CIRCUIT BOARD C EARTH GROUND THIS UNIT HAS EFFECTIVE LIGHTNING PROTECTION ONLY WHEN GROUNDED A...

Page 6: ...ATION 1 19 21 20 21 _ _ _ _ _ _ _ _ 17 43 45 44 45 _ _ _ _ _ _ _ _ 2 19 22 20 22 _ _ _ _ _ _ _ _ 18 43 46 44 46 _ _ _ _ _ _ _ _ 3 19 23 20 23 _ _ _ _ _ _ _ _ 19 43 47 44 47 _ _ _ _ _ _ _ _ 4 19 24 20...

Page 7: ...AXIMUM TOTAL CURRENT AVAILABLE FROM THESE OUTPUTS IS 700 MA THIS TOTAL OF ALL OUTPUTS SHOULD NOT BE EXCEEDED USE THE PROVIDED CHART TO TOTAL THE SUM OF THE OUTPUTS VOLTAGE OUTPUT TERMINALS CURRENT USE...

Page 8: ...CALCULATING THE TOTAL CURRENT USED BY THE SYSTEM THE REMOTE CONSOLE IS TERMINATED WITH AN EIGHT CONDUCTOR MODULAR CORD AN EIGHT CONDUCTOR MODULAR JACK IS SUPPLIED TO TERMINATE THE CABLE RUN BETWEEN TH...

Page 9: ...C 28 MA NOTE TOTAL CURRENT FROM ALL OUTPUTS NOT TO EXCEED 800 MA FUSES BATTERY FUSE 2 5 SB 3 AG AUXILIARY POWER FUSES 5 x 20MM 500MA ZONE PARAMETERS LOOP RESPONSE TIME 250 MS TO ACTIVATE 125 MS TO RE...

Page 10: ...PREPARED BY THE FEDERAL COMMUNICATION COMMISSION HELPFUL HOW TO IDENTIFY AND RESOLVE RADIO TV INTERFERENCE PROBLEMS THIS BOOKLET IS AVAILABLE FROM THE U S GOVERNMENT PRINTING OFFICE WASHINGTON DC 204...

Page 11: ......

Page 12: ...PLAY CONSOLE THE REMOTE CONSOLE DISPLAYS AND CONTROLS ZONE STATUS AND SYSTEM CONDITIONS THE CONSOLE CONTAINS A DIGITAL KEYPAD ZONE SYSTEM INDICATORS AND AN AUDIBLE SIGNAL A DIGITAL KEYPAD THE DIGITAL...

Page 13: ...THE AUDIBLE ANNUNCIATOR IS NOT RESET THE AUDIBLE SIGNAL WILL SOUND AFTER THE LAST KEY IS PRESSED D MEMORY RESET WHEN A ZONE HAS BEEN VIOLATED THE ZONE MEMORY IS SET IN ORDER TO MONITOR THE ZONE STATU...

Page 14: ...ZONE 2 INDICATOR WILL FLASH BYPASS STATUS OUTPUT WILL TURN ON THE FOLLOWING IS AN EXAMPLE OF THE ZONE UN BYPASS FUNCTION TO UN BYPASS ZONE NUMBER 30 1 LOAD A VALID FOUR DIGIT ACCESS CODE THEN PRESS PO...

Page 15: ...ODE 01 1865 02 9506 03 5198 04 7357 05 9274 06 4742 07 2645 08 2405 09 7928 10 9258 11 8296 12 8320 13 9078 14 9536 15 8878 16 4530 B ZONE DESIGNATIONS STANDARD ZONES 1 24 DAY ZONES 25 32 ALARM CONTRO...

Reviews: