ALARM CONTROLS
1 2 3
4 5 6
7 8 9
*
0
#
PAGE 2
YELLOW LED INDICATOR AND TONES
THE YELLOW LED AND BUILT-IN BUZZER GIVE THE FOLLOWING SIGNALS AND TONES
TONES CAN BE ENABLED OR DISABLED THROUGH PROGRAMMING
If the Installer Code is forgotten, use the DAP jumper to override the forgotten code
permitting the keypad direct entry into the programming mode. Do the following as described:
1. Disconnect the power supply.
2. Move the DAP jumper from OFF to ON position.
3. Reconnect the power supply, (the buzzer turns ON).
4. Move the DAP jumper back to the OFF position, (the buzzer turns OFF).
5. The keypad is now in the programming mode and ready to receive new programming data.
6. Since the old Installer Code was forgotten repeat # 2 in the Program Mode section.
LED SIGNALS
TONES
STATUS
ON
NONE
IN PROGRAMMING MODE
1 FLASH
1 BEEP
SUCCESSFUL KEY ENTRY
2 FLASHES
2 BEEPS
SUCCESSFUL CODE ENTRY
5 FLASHES
5 BEEPS
FAULTY CODE ENTRY
CONTINUOUS FLASHING
CONTINUOUS TONE
DAP JUMPER NOT REPLACED
CONTINUOUS FLASHING
NONE
POWER ON
LED INDICATORS
DAP JUMPER (
DIRECT ACCESS TO PROGRAMMIN
G)
KP-100 KEYPAD
LEDS
DAP JUMPER
RED
GREEN
YELLOW
DAP
ON/OFF
MODEL
KP-100
RELAY
TAMPER
N/C
+
AC/DC
NC NO
COM
EG
IN
RED LED
ON WHEN OUTPUT RELAY IS LOCKED OUT
YELLOW LED
MONITORS POWER INPUT AND KEY PRESS, (SEE CHART BELOW)
GREEN LED
ON DURING THE TIME THE OUTPUT RELAY IS ACTIVE