When the keypad is programmed for
Auto Entry
mode the key that follows the entered
Code Number is
not
required. In this mode the User Code must be the same length as the In-
staller Code and the code length can be from 4 to 8 digits in length.
To program the keypad for Auto Entry press then press then press the key.
#
#
2
8
1
FALSE CODE LOCKOUT FEATURE
CODE ENTRY MODES/AUTO OR MANUAL
The keypad will lockout for 30 seconds after 10 false codes are entered.
The keypad generates 5 beeps for each unsuccessful code entry.
PAGE 4
PROGRAMMING OPTIONS
The keypad can be programmed with additional features by using the following options.
You have only 10 seconds between key entries otherwise the keypad will return
to the Program Mode.
See
ENTERING THE PROGRAM MODE
on page 3.
The keypad must be in the Program Mode in order to install these options.
KEYPAD LOCKOUT
The keypad beeper can be silenced if required. The beeper will not sound when the keys
are pressed.
For silent keypad operation press then press then press the key. The keypad
is now in the Silent Mode. To restore to audible keypad operation press then press
then press the key.
The keypad is now in the audible mode.
The relay can be programmed to turn on or off with each successive entry of the User Code.
Press then press the key. The relay will turn on or off depending upon its last
state. To return relay to Momentary Mode see
SETTING THE RELAY ON TIME
on page 3.
RELAY LATCHING MODE
#
0
3
8
#
1
3
8
KEYPAD SILENT MODE
#
1
4
The keypad can be programmed to notify the user when the output relay is energized or the
egress button has been pressed. This feature is ideal for use with a locking device that is silent.
The buzzer sounds for 1 second.
For Output Annunciation press then press then press the key. The keypad now
has output annunciation.
To disable Output Annunciation press then press then press the key.
#
#
1
8
1
8
OUTPUT ANNUNCIATOR
1
0
The keypad can be temporarily disabled to prevent unauthorized access at night or after office
hours by entering a predetermined lockout code which can be 4 to 8 digits long. The Red LED
will light when the Keypad Lockout is activated.
Press then press the key, then press and enter the lockout code, then
The Keypad Lockout is turned on and off by using the lockout code.
#
#
5 1
2 1
When the keypad is programmed for
Manual
mode the key that follows the entered User
Coder
is
required. In this mode the the User Codes can be from 4 to 8 digits in length but all
the User Codes need not have the same number of digits.
To program the keypad for Manual Mode press then press then press the key.
The keypad is now in the Manual Mode.
#
2
8
0
#