background image

When the keypad is programmed for 

Auto Entry

mode the       key that follows the entered 

Code Number is 

not

required.  In this mode the User Code must be the same length as the In-

staller Code and the code length can be from 4 to 8 digits in length. 
To program the keypad for Auto Entry press              then press       then press the       key.

#

#

2

8

1

FALSE CODE LOCKOUT FEATURE

CODE ENTRY MODES/AUTO OR MANUAL

The keypad will lockout for 30 seconds after 10 false codes are entered.

The keypad generates 5 beeps for each unsuccessful code entry.  

PAGE 4

PROGRAMMING OPTIONS

The keypad can be programmed with additional features by using the following options.

You have only 10 seconds between key entries otherwise the keypad will return
to the Program Mode. 

See 

ENTERING THE PROGRAM MODE

on page 3.

The keypad must be in the Program Mode in order to install these options.

KEYPAD LOCKOUT

The keypad beeper can be silenced if required.  The beeper will not sound when the keys 

are pressed.
For silent keypad operation press             then press        then press the       key.  The keypad

is now in the Silent Mode.  To restore to audible keypad operation press             then press

then press the       key.  

The keypad is now in the audible mode.

The relay can be programmed to turn on or off with each successive entry of the User Code.
Press             then press the        key.  The relay will turn on or off depending upon its last
state.  To return relay to Momentary Mode see 

SETTING THE RELAY ON TIME

on page 3.

RELAY LATCHING MODE

#

0

3

8

#

1

3

8

KEYPAD SILENT MODE

#

1

4

The keypad can be programmed to notify the user when the output relay is energized or the

egress button has been pressed.  This feature is ideal for use with a locking device that is silent.

The buzzer sounds for 1 second.

For Output  Annunciation press             then press        then press the        key. The keypad now

has output annunciation.

To disable Output Annunciation press             then press        then press the        key. 

#

#

1

8

1

8

OUTPUT  ANNUNCIATOR

1

0

The keypad can be temporarily disabled to prevent unauthorized access at night or after office

hours by entering a predetermined lockout code which can be 4 to 8 digits long. The Red LED

will light when the Keypad Lockout is activated.
Press            then press the        key, then press             and enter the lockout code, then 

The Keypad Lockout is turned on and off by using the lockout code.

#

#

5 1

2 1

When the keypad is programmed for 

Manual

mode the       key that follows the entered User

Coder 

is 

required.  In this mode the the User Codes can be from 4 to 8 digits in length but all

the User Codes need not have the same number of digits.    
To program the keypad for Manual Mode press              then press       then press the       key.

The keypad is now in the Manual Mode.

#

2

8

0

#

Summary of Contents for KP-100

Page 1: ...FROM 4 TO 8 DIGITS KEYS ARE BACKLIT FOR VISIBILITY IN DARK AREAS HARD PLASTIC KEYS WITH AUDIBLE AND VISUAL KEY PRESS SINGLE POLE DOUBLE THROW RELAY CONTACTS RATED 5A BUILT IN TAMPER SWITCH BUILT IN BUZZER REQUEST TO EXIT INPUT RED YELLOW AND GREEN LEDS INDICATE KEYPAD STATUS DESIGNED FOR INDOOR USE LIFETIME LIMITED WARRANTY M MO OD DE EL L K KP P 1 10 00 0 ALARM CONTROLS CORPORATION DEER PARK NEW ...

Page 2: ...IFICATIONS OPERATING VOLTAGE 12 OR 24 VOLTAS AC DC AUTO SENSING ACTIVE CURRENT DRAW 50 MA 12 VOLTS 65 MA 24 VOLTS IDLE CURRENT 9 MA MAX 12 VOLTS 17 MA MAX 24 VOLTS RELAY CONTACT RATING 5A 28 VDC 120 VAC RELAY CONTACT ARRANGEMENT SINGLE POLE DOUBLE THROW 1 FORM C EGRESS INPUT NORMALLY OPEN CONTACTS 100 USER CODES CODE LENGTH FROM 4 TO 8 DIGITS LONG DIGITS CAN BE REPEATED KEYPAD LOCKOUT FEATURE RELA...

Page 3: ...SELF CONTAINED DIGITAL ACCESS CONTROL KEYPAD MODEL KP 100 OPERATING INSTRUCTIONS ALARM CONTROLS CORPORATION 19 BRANDYWINE DRIVE P O BOX 280 DEER PARK NY 11729 WWW ALARMCONTROLS COM ...

Page 4: ...TUP ACTIVATING THE PROGRAM MODE KEYPAD INITIATION MODE ENTERING USER CODES DELETING A USER CODE SETTING RELAY ON TIME EXITING THE PROGRAM PROGRAMMING OPTIONS KEYPAD LOCKOUT RELAY LATCHING MODE KEYPAD SILENT MODE OUTPUT ANNUNCIATION AUTO ENTRY MODE FALSE CODE LOCKOUT USER OPERATING INSTRUCTIONS WARRANTY PAGE 5 PAGE 1 PAGE 1 PAGE 1 PAGE 2 PAGE 2 PAGE 3 PAGE 3 PAGE 3 PAGE 3 PAGE 3 PAGE 3 PAGE 3 PAGE ...

Page 5: ...ge IMPORTANT FEATURES FULLY PROGRAMMABLE FROM THE KEYPAD RECESSED OR SURFACE MOUNT BACK BOX SUPPLIED 100 USER CODES WITH CODE LENGTHS FROM 4 TO 8 DIGITS KEYS ARE BACK LIT FOR VISIBILITY IN DARK AREAS KEYS ARE HARD PLASTIC WITH AUDIBLE AND VISUAL KEY PRESS FEEDBACK 10 AMPERE RELAY CONTACTS BUILT IN TAMPER SWITCH BUILT IN BUZZER REQUEST TO EXIT INPUT RED YELLOW AND GREEN LEDS INDICATE THE CONDITION ...

Page 6: ...rns OFF 5 The keypad is now in the programming mode and ready to receive new programming data 6 Since the old Installer Code was forgotten repeat 2 in the Program Mode section LED SIGNALS TONES STATUS ON NONE IN PROGRAMMING MODE 1 FLASH 1 BEEP SUCCESSFUL KEY ENTRY 2 FLASHES 2 BEEPS SUCCESSFUL CODE ENTRY 5 FLASHES 5 BEEPS FAULTY CODE ENTRY CONTINUOUS FLASHING CONTINUOUS TONE DAP JUMPER NOT REPLACED...

Page 7: ... hear two beeps You will now be able to enter an Installer Code 2 Press then enter an Installer Code that can be 4 to 8 digits in length digits can be repeated then press the key The Yellow Led will be on steady you will hear two beeps You are now in the Program Mode Please record the Installer Code for future use The Installer Code may be changed by entering the old Installer Code and repeating 2...

Page 8: ...r off with each successive entry of the User Code Press then press the key The relay will turn on or off depending upon its last state To return relay to Momentary Mode see SETTING THE RELAY ON TIME on page 3 RELAY LATCHING MODE 0 3 8 1 3 8 KEYPAD SILENT MODE 1 4 The keypad can be programmed to notify the user when the output relay is energized or the egress button has been pressed This feature is...

Page 9: ...WARRANTY ALARM CONTROLS CORPORATION Seller 19 BRANDYWINE DRIVE DEER PARK NY 11729 warrants its Digital Keypads The Product to be free from defects in material and workmanship for two years from date of original purchase under normal use and service Seller s obligation is limited to repairing or replacing at its option free of charge for parts and labor or transportation any part proven to be defec...

Reviews: