background image

ALARM CONTROLS CORPOR ATION

IF YOU NEED IT, WE WILL MAKE IT

“QUALITY SECURITY EQUIPMENT SINCE 1971”

19 BRANDYWINE DRIVE, P.O. BOX 280, DEER PARK, NEW YORK 11729

1 800 645-5538  631 586-4220  FAX 631 586-6500

EMAIL: [email protected]   WWW.ALARMCONTROLS.COM

MODEL KP-100 DIGITAL KEYPAD

FOR

ACCESS CONTROL APPLICATIONS

USE DIODE

SUPPLIED

IF REQUIRED

EG

IN

N/C

TAMPER

SWITCH

12/24V

AC/DC

+    

OUTPUT

N/C    C    N/O    

RTE

INPUT

N/O CONTACT

REQUIRED

12/24 VOLT

POWER

SUPPLY

CONNECT

TO PANIC

INPUT

-

MAGNETIC

LOCK

ELECTRIC

STRIKE

REQUEST TO

EXIT STATION

OR

TYPICAL WIRING DIAGRAM

SPECIFICATIONS

OPERATING VOLTAGE: 12 OR 24 VOLTAS AC/DC, AUTO SENSING
ACTIVE CURRENT DRAW : 50 MA. @ 12 VOLTS, 65 MA. @ 24 VOLTS
IDLE CURRENT: 9 MA. MAX. @ 12 VOLTS, 17 MA. MAX. @ 24 VOLTS
RELAY CONTACT RATING: 5A. @ 28 VDC/120 VAC
RELAY CONTACT ARRANGEMENT: SINGLE POLE-DOUBLE THROW, (1 FORM C)
EGRESS INPUT: NORMALLY-OPEN CONTACTS
100 USER CODES, CODE LENGTH FROM 4 TO 8 DIGITS LONG, DIGITS CAN BE REPEATED
KEYPAD LOCKOUT FEATURE
RELAY CAN BE SET FOR MOMENTARY OR LATCHING MODE
FALSE CODE LOCKOUT FEATURE
ADJUSTABLE RELAY ON TIME FROM 1 TO 999 SECONDS
KEYPAD BEEPER CAN BE SILENCED IF REQUIRED
KEYPAD CAN BE PROGRAMMED FOR OUTPUT ANNUNCIATION
BACKLIT KEYS FOR VISIBILITY IN DARK AREAS
SUPPLIED WITH SURFACE MOUNT BACK BOX WITH TAMPER SWITCH
CAN BE FLUSH MOUNTED ON SINGLE GANG ELECTRICAL BOX

Summary of Contents for KP-100

Page 1: ...FROM 4 TO 8 DIGITS KEYS ARE BACKLIT FOR VISIBILITY IN DARK AREAS HARD PLASTIC KEYS WITH AUDIBLE AND VISUAL KEY PRESS SINGLE POLE DOUBLE THROW RELAY CONTACTS RATED 5A BUILT IN TAMPER SWITCH BUILT IN BUZZER REQUEST TO EXIT INPUT RED YELLOW AND GREEN LEDS INDICATE KEYPAD STATUS DESIGNED FOR INDOOR USE LIFETIME LIMITED WARRANTY M MO OD DE EL L K KP P 1 10 00 0 ALARM CONTROLS CORPORATION DEER PARK NEW ...

Page 2: ...IFICATIONS OPERATING VOLTAGE 12 OR 24 VOLTAS AC DC AUTO SENSING ACTIVE CURRENT DRAW 50 MA 12 VOLTS 65 MA 24 VOLTS IDLE CURRENT 9 MA MAX 12 VOLTS 17 MA MAX 24 VOLTS RELAY CONTACT RATING 5A 28 VDC 120 VAC RELAY CONTACT ARRANGEMENT SINGLE POLE DOUBLE THROW 1 FORM C EGRESS INPUT NORMALLY OPEN CONTACTS 100 USER CODES CODE LENGTH FROM 4 TO 8 DIGITS LONG DIGITS CAN BE REPEATED KEYPAD LOCKOUT FEATURE RELA...

Page 3: ...SELF CONTAINED DIGITAL ACCESS CONTROL KEYPAD MODEL KP 100 OPERATING INSTRUCTIONS ALARM CONTROLS CORPORATION 19 BRANDYWINE DRIVE P O BOX 280 DEER PARK NY 11729 WWW ALARMCONTROLS COM ...

Page 4: ...TUP ACTIVATING THE PROGRAM MODE KEYPAD INITIATION MODE ENTERING USER CODES DELETING A USER CODE SETTING RELAY ON TIME EXITING THE PROGRAM PROGRAMMING OPTIONS KEYPAD LOCKOUT RELAY LATCHING MODE KEYPAD SILENT MODE OUTPUT ANNUNCIATION AUTO ENTRY MODE FALSE CODE LOCKOUT USER OPERATING INSTRUCTIONS WARRANTY PAGE 5 PAGE 1 PAGE 1 PAGE 1 PAGE 2 PAGE 2 PAGE 3 PAGE 3 PAGE 3 PAGE 3 PAGE 3 PAGE 3 PAGE 3 PAGE ...

Page 5: ...ge IMPORTANT FEATURES FULLY PROGRAMMABLE FROM THE KEYPAD RECESSED OR SURFACE MOUNT BACK BOX SUPPLIED 100 USER CODES WITH CODE LENGTHS FROM 4 TO 8 DIGITS KEYS ARE BACK LIT FOR VISIBILITY IN DARK AREAS KEYS ARE HARD PLASTIC WITH AUDIBLE AND VISUAL KEY PRESS FEEDBACK 10 AMPERE RELAY CONTACTS BUILT IN TAMPER SWITCH BUILT IN BUZZER REQUEST TO EXIT INPUT RED YELLOW AND GREEN LEDS INDICATE THE CONDITION ...

Page 6: ...rns OFF 5 The keypad is now in the programming mode and ready to receive new programming data 6 Since the old Installer Code was forgotten repeat 2 in the Program Mode section LED SIGNALS TONES STATUS ON NONE IN PROGRAMMING MODE 1 FLASH 1 BEEP SUCCESSFUL KEY ENTRY 2 FLASHES 2 BEEPS SUCCESSFUL CODE ENTRY 5 FLASHES 5 BEEPS FAULTY CODE ENTRY CONTINUOUS FLASHING CONTINUOUS TONE DAP JUMPER NOT REPLACED...

Page 7: ... hear two beeps You will now be able to enter an Installer Code 2 Press then enter an Installer Code that can be 4 to 8 digits in length digits can be repeated then press the key The Yellow Led will be on steady you will hear two beeps You are now in the Program Mode Please record the Installer Code for future use The Installer Code may be changed by entering the old Installer Code and repeating 2...

Page 8: ...r off with each successive entry of the User Code Press then press the key The relay will turn on or off depending upon its last state To return relay to Momentary Mode see SETTING THE RELAY ON TIME on page 3 RELAY LATCHING MODE 0 3 8 1 3 8 KEYPAD SILENT MODE 1 4 The keypad can be programmed to notify the user when the output relay is energized or the egress button has been pressed This feature is...

Page 9: ...WARRANTY ALARM CONTROLS CORPORATION Seller 19 BRANDYWINE DRIVE DEER PARK NY 11729 warrants its Digital Keypads The Product to be free from defects in material and workmanship for two years from date of original purchase under normal use and service Seller s obligation is limited to repairing or replacing at its option free of charge for parts and labor or transportation any part proven to be defec...

Reviews: