Troubleshooting: 
 

The unit does not dehumidify enough / Too little water accumulates in the condensation tank 
 
Please remember that the primary objective is not to gain as much condensation water as possible, but to dry 
and/or keep the room air or ceilings, walls and inventory dry ! 
 
Furthermore, remember that the dehumidifier can only remove moisture from the air and only indirectly from 
materials. Depending on the condition of the ceilings, walls and fixtures, it can take several weeks until they have 
released the stored moisture back into the air! For this reason, we also recommend that if you use your own 
humidity meter (hygrometer), to place it as freely as possible and somewhat away from walls and ceilings, because 
otherwise the determined humidity value of the room air is falsified! 
 
As with all dehumidifiers, the dehumidification performance is decisively influenced by the following factors: 
A) humidity content of the room air and B) heat/temperature in the room. 
Therefore, for safety's sake, here is an excerpt from the dehumidification table at DAUERBETRIEB: 
 

35 degrees 

and 80% r.h. = approx. 18 litres 

and at 90% r.H. = approx. 20 litres 

and at 60% r.H. = approx. 

10 litres 

30 degrees 

and 80% r.h. = approx. 16 litres 

and at 90% r.H. = approx. 18 litres 

and at 60% r.H. = approx. 

8 litres 

20 degrees 

and 80% r.H. = approx.  9 litres  

and at 90% r.H. = approx. 11 litres 

and at 60% r.H. = approx. 

5 litres 

15 degrees 

and 80% r.H. = approx.  7 litres  

and at 90% r.H. = approx.   8 litres 

and at 60% r.H. = approx. 

3 litres 

10 degrees 

and 80% r.h. = approx. 4 litres and at 90% r.H. = approx. 5 litres 

and at 60% r.H. = approx. 2 litres 

  5 degrees 

and 80% r.h. = approx. 3 litres and at 90% r.H. = approx. 4 litres 

and at 60% r.H. = approx. 1 litre 

 
All data are approximate per day (fluctuation tolerance) with a measurement directly at the device input and of 
course these values are only valid with constant temperature and moisture content!

 

 
 
The device rattles or makes running noises 
 
Running noises are mostly caused by the air filter unit. We kindly ask you to remove the air filter once and check 
whether the running noises are still present to the same extent ? 
 
An unfavourable position of the dehumidifier is often the reason for higher running noises. Try changing the position 
a little, as the running noises will then mostly disappear. Optimum and particularly quiet operation can be achieved 
if the dehumidifier is placed on a piece of carpet, doormat or similar during operation! (Stone floors, tiles, laminate 
or parquet, on the other hand, increase the operating noise of the dehumidifier! ) 
 
 
The device is leaking or water is leaking out 
 
In this context, we would like to provide you with the following information:

 

A "leak" on your dehumidifier is actually impossible, unless the main frame is broken and of course something like 
that can be ruled out without force. 
 
If the water still leaks out, then the condensate probably comes from the "emergency drain", which is located 
behind the collection tank at the very top right in a small triangular recess. The reason for this is that the normal 
drain is prevented. This can have the following causes:

 

 
1.  The most common cause is a slight soiling in the drip tray or the left drain (e.g. due to dead insects, dirt or 

similar) and therefore the condensate cannot drain off normally. In this connection, please check the left drain 
once or shake the unit once briefly in the upside-down position. Make sure that you then wait at least 4 hours 
before switching the unit on again! 

2.  The device does not have a straight stand. 
3.  It may be that only a large piece of ice has detached from the cooling fins of your dehumidifier and this leads to 

a short-term blockage. We therefore recommend that you disconnect the unit completely from the power supply 
for a day and then the unit should no longer "leak". 

Summary of Contents for WDH-416S

Page 1: ...an sometimes occur despite careful instructions on the carton For this reason we ask you to leave it standing upright for at least 4 hours before using the unit for the first time so that the refriger...

Page 2: ...objects on the dehumidifier Do not block the exhaust air fins of the unit and please ensure sufficient space clearance at and around the fan Make sure that there is sufficient air supply to the device...

Page 3: ...The device should not be stored or operated in a room with burning heating appliances or open fire Please note that the refrigerant is odourless and a leak cannot be detected immediately by an odour...

Page 4: ...on 3 Display panel for humidity and timer 11 Low air circulation active signal light 4 Signal light of the active timer function 12 Operating people 5 Button for displaying the current temperature 13...

Page 5: ...ed operating time has elapsed the device switches off automatically Determining a start time When the dehumidifier is switched off press the TIMER button to select the desired start time A value betwe...

Page 6: ...ce on sloping or uneven surfaces 4 4 Please always keep a distance of approx 20 cm to the wall to avoid possible overheating of the appliance Furthermore please also ensure a distance of approx 50 cm...

Page 7: ...from its holder the filter grid It is best to clean the air filter carefully under lukewarm water or with a weakly adjusted suction power vacuum cleaner Reattach the air filter strainer to the filter...

Page 8: ...ment directly at the device input and of course these values are only valid with constant temperature and moisture content The device rattles or makes running noises Running noises are mostly caused b...

Page 9: ...equipment Conformity The dehumidifier has been tested and itself and or parts thereof have been manufactured under the following safety standards GS tested by Intertek and of course with CE conformit...

Reviews: