background image

 

Aktobis AG, Borsigstr. 20, D-63110 Rodgau / Germany 

www.AKTOBIS.de

 

Email: [email protected] 

 

Directions for use: 

 
1.  Commissioning 
 

1.1 Insert the power plug properly into the power outlet. 

 

1.2. Check that the condensation tank is properly seated in the dehumidifier. (When using the dehumidifier for the 

first time, it is possible that the "condensation tank full" light is illuminated. Simply pull the condensation tank 
out briefly and then push it right back in again and you are ready to go! ) 

 
1.3 Switch on the device with the operating switch (on/off button). Now press the humidity setting button and set 

your target humidity as desired. The target value "CNT" corresponds to continuous operation ! The value you 
set must be below the current room humidity for the unit to dehumidify. If your value is above the current room 
humidity, the fan runs for 3 minutes and the unit then switches off. If the room humidity rises above the set 
value, the device automatically starts dehumidification operation again. 

 
1.4 Use the air circulation adjustment button to select between low and high fan speed / air circulation. 
 
1.5 If you want to activate/use the timer function (function for determining the remaining time or function for 

specifying a start time), press the TIMER button.

 

 

Determining the remaining run time: Press the TIMER button during operation to select the desired remaining 
run time of the dehumidifier. (A value between 1 - 24 hours can be selected). After this selected operating time 
has elapsed, the device switches off automatically. 

 

Determining a start time: When the dehumidifier is switched off, press the TIMER button to select the desired 
start time. (A value between 1 - 24 hours can be selected). After this selected time has elapsed, the appliance 
switches on automatically (with the last settings used, provided the mains plug has not been disconnected in 
the meantime). 
 

1.6 If you want to use the laundry drying mode, press the button to activate the laundry drying mode. In the laundry 
      drying mode, the air circulation is continuously set to high.dehumidified. The appliance operates in continuous 
      mode here. Exit the laundry drying mode by pressing 
      pressing the button again to activate the laundry drying mode. 
 
1.7 In the air circulation mode ( air purification ) only the fan operates and no dehumidification takes place. 
       Start and stop this setting, by pressing the button to activate the 
       Air circulation mode (air purification). 
 

2.  Emptying the collection tank / When the "Condensation tank full" light is on 
 

When the condensation tank is full, the signal light comes on and the dehumidifier then 
automatically stops its dehumidification operation. Remove the condensation tank and empty 
it. After you have pushed the condensation tank neatly back into the device, the 
dehumidification operation starts again automatically. 

 

3.  Connecting a hose 
 

3.1. You will need a ½ inch plastic hose. 
3.2. Remove the condensation tank for a short time. 
3.3. Pass the plastic hose through the opening above the condensation tank and then connect it to the drip tap (see 

diagrams below). Then push the condensation tank neatly back into the appliance. 

 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for WDH-416S

Page 1: ...an sometimes occur despite careful instructions on the carton For this reason we ask you to leave it standing upright for at least 4 hours before using the unit for the first time so that the refriger...

Page 2: ...objects on the dehumidifier Do not block the exhaust air fins of the unit and please ensure sufficient space clearance at and around the fan Make sure that there is sufficient air supply to the device...

Page 3: ...The device should not be stored or operated in a room with burning heating appliances or open fire Please note that the refrigerant is odourless and a leak cannot be detected immediately by an odour...

Page 4: ...on 3 Display panel for humidity and timer 11 Low air circulation active signal light 4 Signal light of the active timer function 12 Operating people 5 Button for displaying the current temperature 13...

Page 5: ...ed operating time has elapsed the device switches off automatically Determining a start time When the dehumidifier is switched off press the TIMER button to select the desired start time A value betwe...

Page 6: ...ce on sloping or uneven surfaces 4 4 Please always keep a distance of approx 20 cm to the wall to avoid possible overheating of the appliance Furthermore please also ensure a distance of approx 50 cm...

Page 7: ...from its holder the filter grid It is best to clean the air filter carefully under lukewarm water or with a weakly adjusted suction power vacuum cleaner Reattach the air filter strainer to the filter...

Page 8: ...ment directly at the device input and of course these values are only valid with constant temperature and moisture content The device rattles or makes running noises Running noises are mostly caused b...

Page 9: ...equipment Conformity The dehumidifier has been tested and itself and or parts thereof have been manufactured under the following safety standards GS tested by Intertek and of course with CE conformit...