5.2 Cleaning the air filter 
 
The air filter filters lint, hair and coarse dust. The air filter is coated with an antibacterial glaze to inhibit the 
proliferation of bacteria. Furthermore, the air filter ensures that less dust is deposited on the cooling fins and thus 
ensures higher efficiency. 
 

Always clean the filter when it can be assumed that the air intake is reduced by the dirty air filter ! 

Then remove the air filter from its holder (the filter grid). 

It is best to clean the air filter carefully under lukewarm water or with a weakly adjusted (suction power) 
vacuum cleaner. 

Reattach the air filter/strainer to the filter grille and reattach to the back of the unit - DONE. 

 

 

 
 

1.)  Filter grid 

 

2.) Washable filter screen 

 

3.) Insertable active carbon filter 

 
 
 
 

Technical data: 

 

Model Name:   

 

 

 

WDH-416S 

 

Voltage: 

 

 

 

 

220 ~ 240V / 50Hz 

 

Max. Power consumption:

 

 

 

415 W

 

 

Compressor:   

 

 

 

Rotary compressor 

 

Dehumidification capacity (optimal):   

20 ltr./day (35°C / 90% r.h.)

 

 

Dehumidification capacity (standard):

  

16 ltr./day (30°C / 80% r.h.) 

 

Condensation tank:

 

 

 

 

Approx. 3,5 litres 

 

Refrigerant: 

 

 

 

 

R290 (60 g) 

 

Protection class: 

 

 

 

IPX0

 

 

Dimension (H/W/D):

 

 

 

 

553 x 310 x 236 mm

 

 

Weight:

 

 

 

 

 

14 kg 

 

Range of use:

   

 

 

 

5°C ~ 32°C

 

 

 
 
 
 
 

Summary of Contents for WDH-416S

Page 1: ...an sometimes occur despite careful instructions on the carton For this reason we ask you to leave it standing upright for at least 4 hours before using the unit for the first time so that the refriger...

Page 2: ...objects on the dehumidifier Do not block the exhaust air fins of the unit and please ensure sufficient space clearance at and around the fan Make sure that there is sufficient air supply to the device...

Page 3: ...The device should not be stored or operated in a room with burning heating appliances or open fire Please note that the refrigerant is odourless and a leak cannot be detected immediately by an odour...

Page 4: ...on 3 Display panel for humidity and timer 11 Low air circulation active signal light 4 Signal light of the active timer function 12 Operating people 5 Button for displaying the current temperature 13...

Page 5: ...ed operating time has elapsed the device switches off automatically Determining a start time When the dehumidifier is switched off press the TIMER button to select the desired start time A value betwe...

Page 6: ...ce on sloping or uneven surfaces 4 4 Please always keep a distance of approx 20 cm to the wall to avoid possible overheating of the appliance Furthermore please also ensure a distance of approx 50 cm...

Page 7: ...from its holder the filter grid It is best to clean the air filter carefully under lukewarm water or with a weakly adjusted suction power vacuum cleaner Reattach the air filter strainer to the filter...

Page 8: ...ment directly at the device input and of course these values are only valid with constant temperature and moisture content The device rattles or makes running noises Running noises are mostly caused b...

Page 9: ...equipment Conformity The dehumidifier has been tested and itself and or parts thereof have been manufactured under the following safety standards GS tested by Intertek and of course with CE conformit...

Reviews: