FS100™ PORTABLE SPRAYER SYSTEM 

INSTALLATION, OPERATING, AND MAINTENANCE INSTRUCTIONS 

FSG-MNL-00219

 

 

Akron Brass, Inc. 

343 Venture Blvd. 

 

Wooster, OH 44961 

22 

www.akronbrass.com 

 

 

9.

 

CHEMICAL COMPATIBILITY LIST 

The FS100 is a portable sprayer system with a fan nozzle pattern to wet surfaces with cleaning agents. 
The FS100 is a medium pressure sprayer with interchangeable nozzle tips.  Effectiveness of the 
disinfectant operation is dependent on appropriate use and selection of the cleaning agent by the user 
of the sprayer system.  The FS100 provides a means to apply a cleaning agent, but Akron Brass makes no 
warranties or representations regarding the effectiveness of the selected cleaning agent for disinfection 
or decontamination purposes. 

 

READ THESE INSTRUCTIONS AND ALL CHEMICAL OR CLEANING AGENT INSTRUCTIONS AND WARNINGS 
CAREFULLY. Failure to follow all instructions provided with the sprayer, the cleaning agent being used, 
and the AHJ (Authority Having Jurisdiction), may result in serious personal injury. For safe use of this 
product you must read and follow all instructions, including but not limited to:   

-

 

Do not leave a pressure in the sprayer system.  Discharge residual pressure after pump has been 

turned off. 

-

 

Do not store or leave solution in tank after use for extended periods.  Consult with cleaning 

agent supplier for guidance on specific cleaning agent use and storage.   

-

 

Always wear appropriate personal protection when spraying including goggles, gloves and 

additional PPE required by the cleaning agent manufacturer.  

-

 

Never service system if there is pressure in sprayer.  

-

 

Never point spray wand at people, animals or electrically charged equipment.  

-

 

Do not use flammable or explosive cleaning agents or other materials in this sprayer.   

-

 

Do not attempt to modify this sprayer. Use only with manufacturer’s original parts.  

-

 

This sprayer is designed for use with only liquids having the active ingredients listed in the table 

below. Never mix different chemicals together.   

-

 

Always read and follow chemical manufacturer and/or cleaning agent manufacturer’s 

instructions before use with this sprayer, as some chemicals may be hazardous when used with 

this sprayer.  

 

Example Disinfectant Agent 

Purerox™ is an example of a broad spectrum disinfectant that is compatible with this sprayer.  More 

information about its effectiveness is available at  

 

https://icleanforhealth.com/orderp/purerox-covid19-pkg1

 

 

Know the contents of the chemical or cleaning agent being sprayed. Read all Material Safety 

Data Sheets (MSDS) and container labels provided with the chemical or cleaning agent and 

follow the chemical manufacturer’s safety instructions.  

 

Do not operate the sprayer in explosive atmospheres, such as in the presence of flammable 

liquids, gases or dust. Power tools create sparks which may ignite the dust or fumes.  

 

Do not allow bystanders or children in the area while operating this product. Exposure to some 

chemicals can be hazardous.  

Summary of Contents for FS100

Page 1: ...COPYRIGHT 2020 BY IDEX FIRE AND SAFETY ALL RIGHTS RESERVED FS100TM PORTABLE SPRAYER SYSTEM INSTALLATION OPERATING MAINTENANCE INSTRUCTIONS FSG MNL 00219...

Page 2: ...Wooster OH 44961 2 www akronbrass com TABLE OF CONTENTS 1 General Safety 3 2 System Specifications 8 3 System Components 9 4 Initial System Setup 12 5 General Operation 14 6 Maintenance Instructions...

Page 3: ...LY HAZARDOUS SITUATION WHICH IF NOT AVOIDED MAY RESULT IN MINOR OR MODERATE INJURY ADDRESSES PRACTICES NOT RELATED TO PERSONAL INJURY GENERAL DANGERS WARNINGs AND NOTICES Fire and Explosion hazard o F...

Page 4: ...Each chemical such as disinfectants have a unique set of hazards and needs to be handled properly to ensure worker safety o The Akron FS100 Portable Sprayer System can only be used with products that...

Page 5: ...use equipment until you identify and correct the problem o Use an extension cord meeting or exceeding the specifications provided in the extension cord section o To reduce the risk of electric shock...

Page 6: ...arge directly against skin o Post warning notices to restrict access for the period recommended on chemical label o Do not eat drink smoke rub your eyes or touch your bare skin when handling chemicals...

Page 7: ...agent manufacturer and test on a small area before spraying o Ensure the surface being sprayed is compatible with the approved chemical solvent being used o See technical data in this and all other eq...

Page 8: ...AYER SYSTEM INSTALLATION OPERATING AND MAINTENANCE INSTRUCTIONS FSG MNL 00219 Akron Brass Inc 343 Venture Blvd Wooster OH 44961 8 www akronbrass com Figure 3 101 00356 000 Figure 4 101 00357 000 Figur...

Page 9: ...Weight without cart with battery 100 lb Weight Full Unit Weight with user supplied battery and fluid 170 lb Unit Weight without cart with battery and fluid 140 lb Shipping Weight 90 lb Standard Hose...

Page 10: ...With Parts 800 228 1161 Figure 6 System Component Illustration Not all parts illustrated are available from Akron for spare parts SPARE COMPONENTS WAND ASSEMBLY 038 00112 000 PUMP ASSEMBLY 501 00069...

Page 11: ...which could result in loss of power damage to the product and or overheating Extension Cord Requirements Gauge 12 3 grounded Max length 100 feet Power Outlet recommended GFCI ground fault circuit int...

Page 12: ...if necessary the 5 gallon liquid reservoir 3 Remove the cart from the storage container and open the container lid 4 Install the battery inside the compartment using the 2x J bolts and battery strap 5...

Page 13: ...anual to help address any problems 11 Depress the handle until all the water in the reservoir is used Turn the system OFF 12 Remove the cart from the storage container and open the container lid Inspe...

Page 14: ...ATING THE UNIT BEFORE USING THE UNIT THE USER MANUAL SHOULD BE READ AND THE UNIT NEEDS TO BE PUT INTO SERVICE BY HOOKING UP THE PROPER AGM BATTERY PRIMING THE UNIT AND TESTING OPERATION THE LABEL ON T...

Page 15: ...S IN THE RESERVOIR ADD WATER FIRST THEN THE CONCENTRATE SO THAT THE CONCENTRATE IS NOT SITTING UNDILUTED IN THE RESERVOIR FOLLOW ALL SAFETY AND PPE GUIDELINES LISTED ON THE SDS SHEET AND EPA LABEL SPE...

Page 16: ...NOT SPRAYING 7 TURNING THE SYSTEM ON SYSTEM IS TURNED ON VIA THE ON OFF SWITCH THE PUMP WILL PRESSURIZE THE FLUID WHICH CAN BE EXPELLED VIA THE TRIGGER ON THE WAND 8 APPLYING THE PRODUCT ENSURE THE WO...

Page 17: ...E SYSTEM BY PULLING THE WAND TRIGGER 10 STORAGE AFTER THE SYSTEM IS SAFELY SHUTDOWN RETURN THE HOSE WAND AND EXTENSION CORD BACK TO THE STORAGE AREA IF THE SYSTEM IS GOING INTO LONG TERM STORAGE ENSUR...

Page 18: ...open the pump enclosure SPRAYER NOZZLE The most important maintenance task to ensure trouble free operation of your unit is to rinse the nozzle out with clean water after every use This routine clean...

Page 19: ...he base Clean any debris from inside the cap 5 Remove the stainless steel strainer element and clean any debris from or around any of the interior surfaces If needed rinse the strainer element with wa...

Page 20: ...Replace the piston pump seals and check valves using the included maintenance instructions Blockage in the sprayer trigger Pull and release the handle to blow out dirt If unsuccessful remove the nozz...

Page 21: ...NSTRUCTIONS FSG MNL 00219 Akron Brass Inc 343 Venture Blvd Wooster OH 44961 21 www akronbrass com 8 BATTERY CHARGER GENERAL OPERATION INSTALLATION AND MAINTENANCE FULLY AUTOMATIC AND INSTALLED IN THE...

Page 22: ...use and storage Always wear appropriate personal protection when spraying including goggles gloves and additional PPE required by the cleaning agent manufacturer Never service system if there is pres...

Page 23: ...k do not put the sprayer into water or other liquid Do not place or store the sprayer where it can fall or be pulled into a tub or sink The list below is intended to provide guidance to the user about...

Page 24: ...rated hoses leaks clogged nozzles and missing or damaged parts If damaged have the product repaired before use Some chemicals or cleaning agents may surfaces being cleaned Check with chemical or clean...

Page 25: ...re Blvd Wooster OH 44961 25 www akronbrass com 10 WARRANTY STATEMENT REFER TO WARRANTY STATEMENT ON AKRON BRASS WEBSITE https www akronbrass com customer support warranty Akron FS100 Portable Sprayer...