background image

 

FS100™ PORTABLE SPRAYER SYSTEM 

INSTALLATION, OPERATING, AND MAINTENANCE INSTRUCTIONS 

FSG-MNL-00219

 

 

Akron Brass, Inc. 

343 Venture Blvd. 

 

Wooster, OH 44961 

14 

www.akronbrass.com 

 

 

5.

 

GENERAL OPERATION

 

Before starting operation, a nozzle should be selected based upon the desired application.  The 

system includes three different styles and they can easily be swapped out by using a wrench.  

Refer to the Wand Nozzle Tip Selection part of the Initial Unit Setup section. 

 

 

1.  COMMISSIONING 

 

REVIEW ALL SAFETY WARNINGS IN THE 

MANUAL BEFORE OPERATING THE UNIT

 

 

BEFORE USING THE UNIT, THE USER MANUAL 

SHOULD BE READ AND THE UNIT NEEDS TO BE 

PUT INTO SERVICE BY HOOKING UP THE PROPER 

AGM BATTERY, PRIMING THE UNIT, AND 

TESTING OPERATION.   

 

THE LABEL ON THE TANK HAS A PLACE TO 

WRITE DOWN THE CHEMICAL CURRENTLY IN 

USE AND THE DATE ADDED. 

 

 

2.  SURFACE PREP 

 

 

CLEAN HEAVILY SOILED AREAS WITH SOAP AND 

WATER FIRST BEFORE DISINFECTING, PER 

RECOMMENDATION OF THE AREA HAVING 

JURISDICTION (AHJ). 

 

 

3.  SAFETY REQUIREMENTS 

 

ONLY USE THIS PRODUCT WITH APPROVED 

DISINFECTANTS SUITABLE FOR USE WITH THE 

FS100.* 
REFER TO THE SDS SHEETS AND AUTHORITY 

HAVING JURISDICTION (AHJ) FOR THE PROPER 

PPE, CONCENTRATION, AND APPLICATION 

METHODS. 

*refer to active ingredient compatibility list in 

the FS100™ user manual 

Summary of Contents for FS100

Page 1: ...COPYRIGHT 2020 BY IDEX FIRE AND SAFETY ALL RIGHTS RESERVED FS100TM PORTABLE SPRAYER SYSTEM INSTALLATION OPERATING MAINTENANCE INSTRUCTIONS FSG MNL 00219...

Page 2: ...Wooster OH 44961 2 www akronbrass com TABLE OF CONTENTS 1 General Safety 3 2 System Specifications 8 3 System Components 9 4 Initial System Setup 12 5 General Operation 14 6 Maintenance Instructions...

Page 3: ...LY HAZARDOUS SITUATION WHICH IF NOT AVOIDED MAY RESULT IN MINOR OR MODERATE INJURY ADDRESSES PRACTICES NOT RELATED TO PERSONAL INJURY GENERAL DANGERS WARNINGs AND NOTICES Fire and Explosion hazard o F...

Page 4: ...Each chemical such as disinfectants have a unique set of hazards and needs to be handled properly to ensure worker safety o The Akron FS100 Portable Sprayer System can only be used with products that...

Page 5: ...use equipment until you identify and correct the problem o Use an extension cord meeting or exceeding the specifications provided in the extension cord section o To reduce the risk of electric shock...

Page 6: ...arge directly against skin o Post warning notices to restrict access for the period recommended on chemical label o Do not eat drink smoke rub your eyes or touch your bare skin when handling chemicals...

Page 7: ...agent manufacturer and test on a small area before spraying o Ensure the surface being sprayed is compatible with the approved chemical solvent being used o See technical data in this and all other eq...

Page 8: ...AYER SYSTEM INSTALLATION OPERATING AND MAINTENANCE INSTRUCTIONS FSG MNL 00219 Akron Brass Inc 343 Venture Blvd Wooster OH 44961 8 www akronbrass com Figure 3 101 00356 000 Figure 4 101 00357 000 Figur...

Page 9: ...Weight without cart with battery 100 lb Weight Full Unit Weight with user supplied battery and fluid 170 lb Unit Weight without cart with battery and fluid 140 lb Shipping Weight 90 lb Standard Hose...

Page 10: ...With Parts 800 228 1161 Figure 6 System Component Illustration Not all parts illustrated are available from Akron for spare parts SPARE COMPONENTS WAND ASSEMBLY 038 00112 000 PUMP ASSEMBLY 501 00069...

Page 11: ...which could result in loss of power damage to the product and or overheating Extension Cord Requirements Gauge 12 3 grounded Max length 100 feet Power Outlet recommended GFCI ground fault circuit int...

Page 12: ...if necessary the 5 gallon liquid reservoir 3 Remove the cart from the storage container and open the container lid 4 Install the battery inside the compartment using the 2x J bolts and battery strap 5...

Page 13: ...anual to help address any problems 11 Depress the handle until all the water in the reservoir is used Turn the system OFF 12 Remove the cart from the storage container and open the container lid Inspe...

Page 14: ...ATING THE UNIT BEFORE USING THE UNIT THE USER MANUAL SHOULD BE READ AND THE UNIT NEEDS TO BE PUT INTO SERVICE BY HOOKING UP THE PROPER AGM BATTERY PRIMING THE UNIT AND TESTING OPERATION THE LABEL ON T...

Page 15: ...S IN THE RESERVOIR ADD WATER FIRST THEN THE CONCENTRATE SO THAT THE CONCENTRATE IS NOT SITTING UNDILUTED IN THE RESERVOIR FOLLOW ALL SAFETY AND PPE GUIDELINES LISTED ON THE SDS SHEET AND EPA LABEL SPE...

Page 16: ...NOT SPRAYING 7 TURNING THE SYSTEM ON SYSTEM IS TURNED ON VIA THE ON OFF SWITCH THE PUMP WILL PRESSURIZE THE FLUID WHICH CAN BE EXPELLED VIA THE TRIGGER ON THE WAND 8 APPLYING THE PRODUCT ENSURE THE WO...

Page 17: ...E SYSTEM BY PULLING THE WAND TRIGGER 10 STORAGE AFTER THE SYSTEM IS SAFELY SHUTDOWN RETURN THE HOSE WAND AND EXTENSION CORD BACK TO THE STORAGE AREA IF THE SYSTEM IS GOING INTO LONG TERM STORAGE ENSUR...

Page 18: ...open the pump enclosure SPRAYER NOZZLE The most important maintenance task to ensure trouble free operation of your unit is to rinse the nozzle out with clean water after every use This routine clean...

Page 19: ...he base Clean any debris from inside the cap 5 Remove the stainless steel strainer element and clean any debris from or around any of the interior surfaces If needed rinse the strainer element with wa...

Page 20: ...Replace the piston pump seals and check valves using the included maintenance instructions Blockage in the sprayer trigger Pull and release the handle to blow out dirt If unsuccessful remove the nozz...

Page 21: ...NSTRUCTIONS FSG MNL 00219 Akron Brass Inc 343 Venture Blvd Wooster OH 44961 21 www akronbrass com 8 BATTERY CHARGER GENERAL OPERATION INSTALLATION AND MAINTENANCE FULLY AUTOMATIC AND INSTALLED IN THE...

Page 22: ...use and storage Always wear appropriate personal protection when spraying including goggles gloves and additional PPE required by the cleaning agent manufacturer Never service system if there is pres...

Page 23: ...k do not put the sprayer into water or other liquid Do not place or store the sprayer where it can fall or be pulled into a tub or sink The list below is intended to provide guidance to the user about...

Page 24: ...rated hoses leaks clogged nozzles and missing or damaged parts If damaged have the product repaired before use Some chemicals or cleaning agents may surfaces being cleaned Check with chemical or clean...

Page 25: ...re Blvd Wooster OH 44961 25 www akronbrass com 10 WARRANTY STATEMENT REFER TO WARRANTY STATEMENT ON AKRON BRASS WEBSITE https www akronbrass com customer support warranty Akron FS100 Portable Sprayer...

Reviews: