6.6 60320014
3356 TREDENT DUAL GALLONAGE W/ NOVO SENSORS
CONNECTOR – J1
Pin
Function
Configuration
1
Vehicle B
Vehicle B
2
Vehicle Battery -
Chassis/Ground/Negative
3
Aux. B (Optional)
Positive
4
Aux. Battery - (Optional)
Negative
5
H-Bridge – Axis 5
(On) Discharge moves on when pin 5 positive with respect to pin 6
6
(Off) Discharge moves off when pin 6 positive with respect to pin 5
7
Output #1
Switch Panel LED (Sourcing Out, 2 Amps Max.)
8
Output #2
Discharge ON (Sourcing Out, 2 Amps Max.)
9
Output #3
Gallonage High (Sourcing Out, 2 Amps Max.)
10
Bistable Relay Contact
Output (Form C)
Common
11
N.O. Contact (1 Amp Max.) Connected to pin 10 when Parked (Stowed)
12
N.C. Contact (1 Amp Max.) Connected to pin 10 when Unparked (Deployed)
13
Switch Input #1
(Enable) Connect to +Bat. Or –Bat. Disconnect to Disable
14
Switch Input #2
(Master Right/L¯e¯f¯t¯ ) Connect to +Bat for Right, to –Bat for Left (Rotation)
15
Switch Input #3
(Master Up/D¯o¯w¯n¯ ) Connect to +Bat for Up, to –Bat for Down (Elevation)
16
Switch Input #4
(Master Stream/F¯o¯g¯ ) Connect to +Bat for Stream, to –Bat for Fog (Pattern)
17
Switch Input #5
(Discharge On/O¯f¯f¯ ) Connect to +Bat for On, to –Bat, or N.C. for Off
18
Switch Input #6
(Gallonage High/L¯o¯w¯ ) Connect to +Bat for High, to –Bat for Low (Gallonage)
19
Switch Input #7
(Osc. Set/P¯a¯u¯s¯e¯ ) Connect to +Bat for Set, to –Bat for Pause (Oscillation)
20
Switch Input #8
(Unpark/P¯a¯r¯k¯ ) Connect to +Bat for Right, to –Bat for Left (Deploy/S¯t¯o¯w¯ )
21
Switch Input #9
(Unused)
22
Aux. Power Out
(Communications Power) (Aux. Power – 1 Amp)
23
CAN HI
Vehicle CAN – J1939 (optional)
24
CAN LO
Vehicle CAN – J1939 (optional)
25
Common
(Communications Power) (Common – Ground)
26
CAN HI
(Unused)
27
CAN LO
(Unused)
28
DATA +
DATA B(+) RS-485 (Optional)
29
DATA -
DATA A(-) RS-485 (Optional)
NOTE: It is always best to consult the control drawing D-1032-507 for up to date details.