2.4.4 Generic DC Power/Signal Connector Pin-out
(Example below from part number 60320014 – 3356 Trident Dual Gallonage monitor)
29 Pin Male Mixed AWG Connector – HDP26-24-29SE
Pin Number
Type
Potential Function
Comments
AWG
1
Power Input
(Vehicle)
+ Battery
Main Battery
12
2
- Battery
12
3
Power Input
(Aux. Battery Box)
+ Battery
Auxiliary Battery
(Optional)
12
4
- Battery
12
5
H-Bridge
Axis #5
+ (Open)
Electric-Riser or Valve
16
6
- (Close)
16
7
Logic Output #1
Panel LED
Current Sourcing
(2 Amps Max.)
16
8
Logic Output #2
Discharge ON
16
9
Logic Output #3
High Gallonage
16
10
Bi-stable Relay
Contact Output
(Form C)
Common
(Enable Output
to Warning Light
Circuit or other)
16
11
N.O. (1 amp Max.)
16
12
N.C. (1 amp Max.)
16
13
Switch Input #1
Enable Input
(Fixed Function)
16
14
Switch Input #2
(+v) Right/Left (-v)
16
15
Switch Input #3
(+v) Up/Down (-v)
16
16
Switch Input #4
(+v) Stream/Fog (-v)
16
17
Switch Input #5
Discharge (+v)
16
18
Switch Input #6
Gallonage High(+v)/Low(-v)
20
19
Switch Input #7
Oscillate: Start/Set(+v) Pause/Resume (-v)
16
20
Switch Input #8
(+v) Deploy/Stow (-v)
20
21
Switch Input #9
Moniter Specific Option
16
22
B Out
(Peripheral Power) 1 Amp Max.
Communications to
vehicle bus and/or smart
peripherals
16
23
Data +
To external J1939
vehicle CAN bus
20
24
Data -
20
25
Battery - Out
(Peripheral Power) Common-Ground
16
26
Data+
NOT USED
16
27
Data-
20
28
Data+
NOT USED
16
29
Data-
20
Table 2-3 Generic DC Power/Signal Connector Pin-out
See Appendix for wiring specific to your monitor. (Reference the part number on your Universal II enclosure to identify your specific
monitor configuration. This part number can be found on a label between the J1 and J2 connectors).
12