3516526A02 Ed. 01
5
2
1
Constant:
Stand-By Mode activated. Regulation
is paused.
Flashing:
Controlled stop process for the regu-
lation in progress.
Constant:
Cold room door open.
Flashing:
The door has been open for a longer
time than defined in parameter A12.
There is an active alarm (No HACCP or temper-
ature).
Constant:
HACCP alarm active.
Flashing:
HACCP alarm recorded and
unconfirmed To acknowledge an HACCP alarm,
press the
key.
The temperature alarm is active.
Constant:
Evaporator fans active.
Flashing:
The evaporator fans
should be active but something is
preventing them from activating.
Constant:
The COOL relay is active.
Flashing:
The COOL relay should be active but a
delay or protection is preventing this.
Pulsing:
Expansion valve regulated.
Constant:
The SELFDRIVE mode is active.
Flashing:
An error has been detected in SELF-
DRIVE mode. To view it, press the
key.
Constant:
Compressor active.
Flashing:
The compressor should be active but
a delay or protection is preventing this.
Defrosting active.
Continuous cycle mode active.
Cold room light active.
Alarm in progress muted.
Temperature displayed in ° Fahrenheit / ° cen-
tigrade.
Programming mode active.
Lower display showing the real time superheat-
ing value.
Lower display showing percentage of EEV
opening or percentage of evaporator fan power
(depending on configuration)
Lower display showing low pressure in psi / bar.
1: Display
2: Keypad
Description
Summary of Contents for 16526A
Page 43: ...3516526A02 Ed 01 43...