Model No:
AC-S10CK_S10HK
Version 1.0
closing it for
1 minute
. Repeat
3
times.
F
After purging the air, use a torque wrench to tighten the flare nut on the 2-way
valve.
l
Check the flare connections for gas leakage.
l
Disconnect the charge set and the gas cylinder, and set the 2-way and 3-way
valves to the open position.
F
Be sure to use a hexagonal wrench to operate the valve spindles.
l
Mount the valve caps and the service port cap.
F
Use torque wrench to tighten the service port cap to a torque of 1.8kg.m.
F
Be sure to check for gas leakage.
l
Caution
: Do not leak the gas in the air during air purging.
4. BALANCE REFRIGERANT OF THE 2-WAY, 3-WAY VALVES (GAS LEAKED)
l
Confirm that both the 2-way and 3-way valves are set to the back seat.
l
Connect the charge set to the 3-way valve’s service port.