The indoor fan motor speed will be controlled as following. (for 24K heat pump)
7. SMART MODE OPERATION
l
When SMART air conditioning is selected, the operation mode and preset
temperature are set automatically according to the room temperature at starting
operation.
l
The operation procedure of
cooling only
is as following.
Intake air temperature at
operation start
Over 26
o
C
Below 26
o
C
Preset temperature
26
o
C
Intake air temperature minus
1.5
o
C
Operation mode
COOLING
DRY
*The initial mode will be continued and independent upon the room temperature
changing.
l
The operation procedure of
heat pump
is as following.