3. REFRIGERANT PIPING
l
The maximum length of the connecting refrigerant piping between indoor unit
and outdoor unit is
15m
and the maximum elevation difference between indoor
and outdoor units are
5m
.
l
If the refrigerant piping is longer than
7m
,additional refrigerant charge
20g/m
for
below 1/2 inch gas pipe and 3
0g/m
for below 5/8 or 3/4 inch gas pipe is advis-
able.
l
Outside diameter of the refrigerant piping is as following.
Models
OD of liquid pipe
(small pipe)
OD of gas pipe
(large pipe)
7K, 9K (COOLING ONLY & HEAT PUMP
6mm or 1/4 inch
10mm or 3/8 inch
12K, 18K,24K ( COOLING ONLY &
HEAT PUMP)
6mm or 1/4 inch
12mm or 1/2 inch