9
Subject to change without notice | 83018300lUK – Translation of the original operating manual | ait-deutschland GmbH
WPS 61
WTPSK 100
UPS 140
Type
Series buffer tanks ı Stratified storage tanks ı Stratified storage tanks Solar
• ı — ı —
• ı • ı —
• ı — ı —
Hot water tank
Energy efficiency class according to ErP
…
B
B
A
Standing loss according to ErP (at 65°C)
W
33
41
31
Tank volume according to ErP
l
60
100
139
Max. operating pressure (except SVGW)
bar
6
6
3
Test pressure
bar
12
9
4,5
Max. operating temperature
°C
- I 95
5 I 95
- I 95
General unit data
Dimensions: Diameter ı Height (see dimensioned drawing for rest)
mm ı mm
450 ı 809
524 ı 855
- ı 630
Tilt dimension
mm
930
1005
-
Heating water connections
…
2 x R 1½" AG
4 x Rp 1" IG
2 x R 1¼" AG
Solar connections
…
-
-
-
Net weight
kg
24
41
75
Heating element (optional)
…
-
-
EHZI 45, EHZ 60
EHZ 75, EHZ 90
Heating element connections
…
-
-
1 x Rp 1½"
Maximum output of electric heating element
kW
-
-
1 x 9,0
Insulation
material: Rigid PU foam ı Soft PU-foam
• yes — no
• ı —
• ı —
• ı —
Insulation thickness
mm
45
42
50
Sheet metal jacket ı Foil jacket
• yes — no
• ı —
• ı —
• ı —
813557d
Manufacturer: ait deutschland GmbH
Tank name
TPS 200
TPSK 200
TPS 500.1
Type
Series buffer tanks ı Stratified storage tanks ı Stratified storage tanks Solar
— ı • ı —
— ı • ı —
— ı • ı —
Hot water tank
Energy efficiency class according to ErP
…
B
B
B
Standing loss according to ErP (at 65°C)
W
53
55
72
Tank volume according to ErP
l
200
201
472
Max. operating pressure (except SVGW)
bar
3
3
3
Test pressure
bar
4,5
4,5
4,5
Max. operating temperature
°C
- I 95
7 I 95
- I 95
General unit data
Dimensions: Diameter ı Height (see dimensioned drawing for rest)
mm ı mm
600 ı 1300
600 ı 1268
760 ı 1930
Tilt dimension
mm
1440
1440
2080
Heating water connections
…
4 x Rp 1½" IG
4 x Rp 1½" IG
8 x Rp 2" IG
Solar connections
…
-
-
-
Net weight
kg
60
60
111
Heating element (optional)
…
EHZI 45, EHZ 60 EHZI 45, EHZ 60 EHZI 45, EHZ 60
EHZ 75
Heating element connections
…
1 x Rp 1½"
3 x Rp 1½"
3 x Rp 1½"
Maximum output of electric heating element
kW
1 x 6,0
3 x 6,0
3 x 7,5
Insulation
material: Rigid PU foam ı Soft PU-foam
• yes — no
• ı —
• ı —
• ı —
Insulation thickness
mm
45
45
80
Sheet metal jacket ı Foil jacket
• yes — no
— ı •
• ı —
— ı •
813557d
Manufacturer: ait deutschland GmbH
Tank name
WPS 61 – TPS 500.1
Technical Data