8
Subject to change without notice | 83018300lUK – Translation of the original operating manual | ait-deutschland GmbH
10.4 Installation of the sensor for the
heating and heat pump regulator
Series buffer tanks
(base buffer tank, free-standing)
The sensor for the heating and heat pump regulator is
already installed in the heat pump in the factory.
Parallel buffer tank
Stratified buffer tanks TPS
On site, you
must
install the sensor included with the
tank for the heating and heat pump regulator in one of
the sensor pockets provided.
For positioning: "Dimensional drawings“, from
page 11, for respective model
Stratified buffer tank Cooling TPSK
On site, you
must
install the two sensors included with
the tank for the heating and heat pump regulators, in
the sensor pockets provided.
For positioning: "Dimensional drawings“, from
page 11, for respective model
Stratified buffer tank wall-mounted cooling
WTPSK
On site, you
must
install the two sensors included with
the tank for the heating and heat pump regulators, in
the sensor pockets provided.
For positioning: "Dimensional drawings“, from
page 11, for respective model
11
Insulation of the connections
and the storage tank
NOTE
Insulate in accordance with applicable local
standards and directives.
1. Check seals of all hydraulic connections. Conduct
pressure test.
2. Insulate all connections, pipes and cables.
IMPORTANT
The insulation of TPSK-/WTPSK tanks of the
connections and lines must be moistureproof.
12
Draining the storage tank
IMPORTANT
When draining the storage tank, always en-
sure adequate ventilation.