background image

5

Subject to change without notice  |  83018300lUK – Translation of the original operating manual |  ait-deutschland GmbH

Addresses  for  purchasing  accessories,  for  servicing 

or  for  answers  to  questions  about  the  unit  and  this 

operating manual can be found on the internet and are 

kept up-to-date.

  “Contact” in the heat pump operating manual

Warranty / Guarantee

For warranty and guarantee conditions, please refer to 

the purchase documents.

 NOTE

Please contact your dealer about all matters 

concerning warranties and guarantees.

8  Disposal

When decommissioning the unit, always comply with 

applicable laws, directives and standards concerning 

recovery, recycling and disposal.

Scope of delivery

 

● Storage tank

 

● additional for TPS /WTPSK: 

 

1 sensor for heating and heat pump regulator.

 

● additional for TPSK: 

 

2 sensor for heating and heat pump regulator.

1.  Inspect the delivery for outwardly visible signs of 

damage.

2.  Check to make sure that the delivery is complete. 

 

Any  defects  or  incorrect  deliveries  must  be 

claimed immediately.

Refer  to  the  rating  plate  attached  to  the  delivered 

storage tank to find out what type of storage tank it is. 

The abbreviations stand for the following:

 

WPS  = Series buffer tank, wall-mounted

 

UPS  = Series  buffer  tank,  base  unit  type, 

 

free-standing

 

TPS  = Stratified buffer tank (= parallel buffer 

tank)

 

WTPSK  =Wall-mounted, vapour diffusion tight, 

insulated, striated buffer tank (suitable 

for reversible systems)

 

TPSK  = Vapour  diffusion  tight,  insulated,  stri-

ated buffer tank (suitable for reversible 

systems)

9.1  Accessories

 IMPORTANT

Use only original accessories from the manu-

facturer of the unit.

Select electrical heating elements from 4.5 to 9 kW for 

the specific system and order separately.

  For  information  on  which  electrical  heating  ele-

ment  is  suitable  for  the  storage  tank:  "Technical 

Data“, from page 9, for the respective model

Summary of Contents for 15016001

Page 1: ...UK 83018300lUK Translation of the original operating manual Accessories for heat pumps Operating Manual Series buffer tanks Stratified storage tanks...

Page 2: ...he respective model This operating manual is intended only for persons assigned to work on or operate the unit Treat all constituent parts confidentially The information contained herein is protected...

Page 3: ...Transport to installation location 6 10 2 Installation 6 10 3 Assembly 6 10 4 Installation of the sensor for the heating and heat pump regulator 8 11 Insulation of the connections and the storage tank...

Page 4: ...rs is suitable for all age groups of persons who are able to understand the activities and the resulting consequences and can car ry out the necessary activities Children and adults who are not experi...

Page 5: ...heat pump regulator 1 Inspect the delivery for outwardly visible signs of damage 2 Check to make sure that the delivery is complete Any defects or incorrect deliveries must be claimed immediately Refe...

Page 6: ...model 10 1 Transport to installation location To avoid damage during transport transport the storage tank secured on the wooden pallet to its final installation location using a lifting truck WARNING...

Page 7: ...f the insulating cover 9 Seal the butt joint with additional insulating tape 10 Attach external insulation at the base 11 Remove packaging from the insulating rings 12 Attach insulating rings at the c...

Page 8: ...nsors included with the tank for the heating and heat pump regulators in the sensor pockets provided For positioning Dimensional drawings from page 11 for respective model Stratified buffer tank wall...

Page 9: ...m 45 42 50 Sheet metal jacket Foil jacket yes no 813557d Manufacturer ait deutschland GmbH Tank name TPS 200 TPSK 200 TPS 500 1 Type Series buffer tanks Stratified storage tanks Stratified storage tan...

Page 10: ...sulation thickness mm 45 80 80 Sheet metal jacket Foil jacket yes no 813557d Manufacturer ait deutschland GmbH Tank name TPSK 1000 WD TPSK 1000 TPS 1500 TPSK 1500 WD TPSK 1500 Type Series buffer tanks...

Page 11: ...5 100 395 450 A C de DE819421b sche nderungen vorbehalten a e in mm ariante 1 orderansicht Draufsicht 5 4 3 2 1 4 3 2 1 b Zust nderungstext M 007 2014 Datum 26 3 2014 D D D 26 3 2014 16 11 2012 M 007...

Page 12: ...vorbehalten Alle Ma e in mm A Vorderansicht C Draufsicht G Detailansicht A 4 3 2 1 A B C D E F Schutzvermerk ISO 16016 beachten Keys UK819424a All dimensions in mm Pos Name Dimension A Front view C Pl...

Page 13: ...F hler Sicherheitsventil R 1 2 AG 2 Heizwasser Austritt R 1 1 4 AG 3 Heizwasser Eintritt R 1 1 4 AG 4 Muffe f r Elektroheizstab R 1 1 2 IG 4 3 2 1 Schutzvermerk nach DIN 34 beachten A B C D E F a Keys...

Page 14: ...chluss f r Entleerungshahn R 3 4 AG 5 Muffe f r Entl ftungs und Sicherheitsventil R 1 IG 6 Tauchrohr f r F hler i 8mm Keys UK819304c All dimensions in mm Pos Name Dimension 1 Heating water R 1 1 2 IG...

Page 15: ...chluss f r Entleerungshahn R 3 4 AG 5 Muffe f r Entl ftungs und Sicherheitsventil R 1 IG 6 Tauchrohr f r F hler i 8mm Keys UK819350 All dimensions in mm Pos Name Dimension 1 Heating water R 1 1 2 IG 2...

Page 16: ...lten Alle Ma e in mm 5 4 3 2 1 4 3 2 1 Zust nderungstext 2 M 053 2014 Keys UK819459 All dimensions in mm Pos Name Dimension 1 Connection for emptying tap R 1 AG 2 Immersion tube for sensor pocket i 12...

Page 17: ...me Dimension 1 Heating water R 2 IG 2 Bushing for sensor electric heating element R 1 1 2 IG 3 Bushing for sensor sensor pocket R 1 2 IG 4 Connection for emptying tap R 1 AG 5 Bushing for sensor bleed...

Page 18: ...6 Anschluss f r Entleerungshahn R 1 AG 3 2 1 B C D E F Schutzvermerk ISO 16016 beachten Pos Name Dimension 1 Heating water R 2 IG 2 Bushing for sensor electric heating element R 1 1 2 IG 3 Bushing fo...

Page 19: ...lle Ma e in mm Pos Bezeichnung Dimension 1 Heizwasser R 2 IG 2 Muffe f r Elekroheizstab R 1 1 2 IG 3 Muffe f r F hlertauchh lse R 1 2 IG 4 Tauchrohr f r F hlerh lse i 11 mm 5 Muffe f r Entl ftungs und...

Page 20: ...alten 5 4 3 2 1 a a Keys UK819506a All dimensions in mm Pos Name Dimension 1 Heating water 8 x flange DN 80 PN 16 2 Bushing for sensor electric heating element R 1 1 2 IG 3 Bushing for sensor sensor p...

Page 21: ...derungen vorbehalten alle Ma e in mm Bezeichnung Dimension 1 Heizwasser 8 x Flansch DN 80 PN 16 2 Muffe f r F hlertauchh lse R 1 1 2 IG 3 Muffe f r Elektroheizstab R 3 4 IG 4 Tauchrohr f r F hlerh lse...

Page 22: ...Ers f 4 3 2 Benennun a Zust nderungstext M 044 2016 Datum 7 4 2017 Von MM Werkstoff Ma stab Datum Name Erstellt Gepr Norm 4 7 2017 Knoll toleranz Allgemein Oberfl chen ArtikelNr DIN ISO 2768 c Knoll 4...

Page 23: ...1001 MFS600S 15028001 WWS 405 2 15211101 MFS 830S 15028101 WWS 507 2 15211201 MFS 1000S 15039901 SWWS 404 2 15211301 WTPSK 100 Split 15079201 SWWS 506 2 15211401 WPSK 40 Split 15079101 814 2013 EN 128...

Page 24: ...ait deutschland GmbH Industriestra e 3 D 95359 Kasendorf www ait deutschland eu UK...

Reviews: