background image

INSTALLATION

7) ELECTRICAL CONNECTION

The  electrical  connection  has  to  be  done  in
accordance  with  all  electrical  and  installation
requirements of the regulation.

Before  proceeding  with  the  connection,  please,
verify that:
-  the  voltage  matches  the  value  shown  on  the

specification plate and the section of the wires of
the electrical system can support the load, which
is also indicated on the specification plate.

- The power of the electrical system and the power

of the outlets is adequate to the maximum power
of the appliance (see the identification label in the
lower part of the body).

-  The  outlets  and  all  the  electrical  system  has  an

efficient  connection  to  the  "earth"  according  with
the  Regulation.  We  disclaim  all  responsabilities
for not observing such points.

-  If  the  appliance  is  not  equipped  with  an  input

cable,  connect  to  the  clump  with  an  adequate
section  cable  keeping  the  "earth"  conductor
longer  than  "live"  ones,  following  the  scheme  of
fig. 7- 8 - 9 - 10.

When  the  connection  to  the  input  system  has
been done through a outlet:

-  apply  to  the  input  cable  "C",  if  unprovided,  a

normalized plug adequate to the load indicated in
the  identification  label.  Connect  the  cables
according  to  the  scheme  of  fig.  7  -  8  -  9  -  10,
making  sure  to  respect  the  undermentioned
respondences:

Letter L (Live) = cable brown colour;
Letter N (Neutral) = cable blue colour;

Earth symbol 

= green - yellow wire.

-  The  input  cable  has  to  be  located  so  that  never

reach the temperature of 90 °C.

-  Please  do  not  use  in  the  connection  any

reduction,  adaptation  that  may  provoke  a  false
contact with following dangerous overheatings.

-  The outlet must be accessible after the built-in.

When the connection has been done directly to
the input system:

- interpose between the appliance and the system

an  onnipolar  switch,  adequate  to  the  load  of  the
appliance,  with  a  minimum  nose  between  the
contacts of 3 mm.

- Keep in mind that the "earth" cable does not have

to be interrupted by the switch.

-  The  electrical  connection  can  also  be  protected

by a differential switch with high sensitivity.

We  recommend  to  fix  the  earth  coloured  cable  to
an appropriate earth installation.

Before performing any service on the electrical
part  of  the  appliance,  it  must  absolutely  be
disconnected from the electrical network.

All  our  products  are  conform  with  the 
European Norms and relative amendments.  

The  product  is  therefore  conform  with  the 
requirements  of  the  European  Directivesin 
force relating to: 
- compatibility electromagnetic (EMC); 
- electrical security (LVD); 
-  restriction  of  use  of  certain  hazardous

substances (RoHS); 

- EcoDesign (ERP).

The appliance must be installed following the
manufacturer's 

instructions. 

The

manufacturer  will  not  be  liable  for  injury  to
persons  or  animals  or  property  damage
caused by an incorrect installation.

If  the  installation  requires  modifications  to
the home's electrical system or if the socket
is  incompatible  with  the  appliance's  plug,
have changes or replacements performed by
professionally-qualified  person.  In  particular,
this  person  must  also  make  sure  that  the
section of the wires of the socket is suitable
for the power absorbed by the appliance.

The product complies with IEC/EN 61000-3-11.
The system impedance measured at the point
of  connection  to  the  electrical  distribution
network must be less than Zmax = 0.43 Ω.

21

WARNINGS!

IMPORTANT!

MODEL: PT1356

Summary of Contents for PCZ VTC 30

Page 1: ...ed The manufacturer declines all responsability for improper installation USE INSTALLATION AND MAINTENANCE INSTRUCTIONS FOR ELECTRICAL BUILT IN HOT PLATES The manufacturer is not responsible for any t...

Page 2: ...or oil can be dangerous and may result in fire NEVER try to extinguish a fire with water but switch off the appliance and then cover flame e g with a lid or a fire blanket WARNING Danger of fire do no...

Page 3: ...he controls on the front panel from a minimum of 1 to a maximum of 9 1 Radiant electric heating element Hi light 18 0 cm of 1800 W 2 Radiant electric heating element Hi light 14 0 cm of 1200 W 7 Touch...

Page 4: ...356 MODEL PT1358 1 ON OFF button cooking zone 2 Capacity level display 0 9 4 Safety lock button 5 Button increase power level 6 Button decrease power level 1 ON OFF button 2 Capacity level display 0 9...

Page 5: ...ing from improper incorrect or unreasonable use During and immediately after operation some parts of the cook top are very hot avoid touching them If the ceramic glass hob is not cleaned immediately t...

Page 6: ...if residual heat exists Zone will be OFF If any cooking stage is in position 0 this display will switch OFF automatically after 10 seconds and the zone OFF sequence will sound If there is residual he...

Page 7: ...2 sec Short beep will be heard and displays will show L letter during 2 sec Then any time when a key will be touched displays will show L during 2 sec heating remains at the same state To deactivate C...

Page 8: ...lays we would follow seeing these power levels number Step 3 But really the heaters would have a Ton cycle totally different Heater 1 and 2 would be working with a real Ton cycle of power level 7 heat...

Page 9: ...f Ft FalloOverTemp Touch NTc Error App Off Fc FalloEepromChecksum Eeprom Checksum Error App Off FH FalloPWMfreq Security Key Control Error App Off FC FalloPWMLevel Security Key Control Error App Off F...

Page 10: ...ral seconds 2 ARRANGEMENT OF THE HEATING ELEMENTS LEFT ANTERIOR LEFT REAR RIGHT REAR RIGHT ANTERIOR When idle the hob will be completely switched off After switching on the hob by pressing the button...

Page 11: ...y fixed on display for 10 seconds Fig A and B during which time the desired power level must be selected between 1 and 8 Confirm it using the button pressed initially After this time a beep sounds and...

Page 12: ...reactivating the heating element required SWITCHING OFF THE HEATING ELEMENTS When the plates are switched off the operating power display indicates 0 The plate will be automatically deactivated 5 seco...

Page 13: ...be exposed to substancial risks Display F and numbers If F and numbers appears in the display your unit has detected a fault The following table list actions you can take to correct the problem Heate...

Page 14: ...d auto check It disap pears when auto check return to secure value If error persist call after sale service FA Security software error This error is a software auto check It disappears when auto check...

Page 15: ...erence for a correct use please look at fig 1 and remind switch on the electricity only after having placed the pot on the cooking zone Use pots and pans with flat solid bottoms Use pots with the same...

Page 16: ...the hob It is very important to clean the surface soon after every use when the glass is still tepid Do not use metallic sponges powder abrasives or corrosive sprays Depending on the dirty level we r...

Page 17: ...or regulating devices on the appliance may only be modified by the manufacturer or by his duly authorized dealer 5 INSERTING After having cleared out all the packing components make sure of the integr...

Page 18: ...hob The ends of the strip must fit together without overlapping Stick the putty to the hotplate uniformly pressing it with fingers Position the hob in the hole in the unit and fasten it in place using...

Page 19: ...19 INSTALLATION FIG 7 MODEL PT1356 POSITION HOOKS ON THE BOTTOM FIG 8...

Page 20: ...INSTALLATION FIG 10 20 MODEL PT1358 POSITION HOOKS ON THE BOTTOM FIG 9...

Page 21: ...dangerous overheatings The outlet must be accessible after the built in When the connection has been done directly to the input system interpose between the appliance and the system an onnipolar switc...

Page 22: ...sent a scheme with the characteristics of the components keeping in mind the contemporaneousness factor TYPE AND SECTION OF THE POWER CABLES FOR 4 5 HEATING ELEMENTS TYPE AND SECTION OF THE POWER CABL...

Page 23: ...t 1800 188 5 ECelectric cooking Energy consumption per kg calculated according to Regulation EU 66 2014 MAINTENANCE MUST ONLY BE PERFORMED BY AUTHORISED PERSONS MODEL 2 HEATING ELEMENTS 30 2 HI LIGHT...

Page 24: ...quired may only be carried out by qualified personnel with the utmost care and attention For this reason always contact your Dealer or your nearest After Sales Centre whenever repairs or adjustments a...

Reviews: