Specifications

Page 51 

48k

Discharge Angle 30°

Heating airflow velocity distributions

Heating temperature distributions

Summary of Contents for YDAX-035H-09M25

Page 1: ...DAX 050H 09M25 CDMX 070N 09M25 YDAX 070H 09M25 CDMX 100N 09M25 YDAX 100H 09M25 CDMX 100N 09M25 YDAX 100H 09T35 CDMX 140N 09M25 YDAX 140H 09T35 IMPORTANT NOTE Read this manual carefully before installi...

Page 2: ...e Criterion Curves 10 Electrical Characteristics 2 Product Features 98 1 Operation Modes and Functions 2 Remote Controller Functions 3 Installation 126 1 Installation Overview 2 Location Selection 3 I...

Page 3: ...awings 11 4 Electrical Wiring Diagrams 18 5 Refrigerant Cycle Diagrams 31 6 Air Velocity and Temperature Distributions 34 7 Capacity Tables 58 8 Capacity Correction Factor for Height Difference 85 9 N...

Page 4: ...chased equipment Indoor Unit Model Outdoor Unit Model Capacity Btu h Power Supply CDMX 035N 09M25 YDAX 035H 09M25 12k 1 220 240V 50Hz CDMX 050N 09M25 YDAX 050H 09M25 18k CDMX 070N 09M25 YDAX 070H 09M2...

Page 5: ...r sound pressure level dB A 42 37 5 34 5 45 4 44 39 50 47 5 42 Indoor sound power level dB A 57 59 59 Indoor unit Dimension WxDxH body mm 570x570x260 570x570x260 830x830x205 Dimension WxDxH panel mm 6...

Page 6: ...R32 R32 R32 GWP 675 675 675 Charged quantity Kg 0 72 1 15 1 5 Design pressure MPa 4 3 1 7 4 3 1 7 4 3 1 7 Refrigerant piping Liquid side Gas side mm inch 6 35 9 52 1 4 3 8 6 35 12 7 1 4 1 2 9 52 15 9...

Page 7: ...r level dB A 64 64 Indoor unit Dimension WxDxH body mm 830x830x245 830x830x245 Dimension WxDxH panel mm 950x950x55 950x950x55 Packing WxDxH body mm 910x910x290 910x910x290 Packing WxDxH panel mm 1035x...

Page 8: ...WP 675 675 Charged quantity Kg 2 2 4 Design pressure MPa 4 3 1 7 4 3 1 7 Refrigerant piping Liquid side Gas side mm inch 9 52 15 9 3 8 5 8 9 52 15 9 3 8 5 8 Max refrigerant pipe length m 50 75 Max dif...

Page 9: ...48 Indoor sound power level dB A 66 Indoor unit Dimension WxDxH body mm 830x830x287 Dimension WxDxH panel mm 950x950x55 Packing WxDxH body mm 910x910x330 Packing WxDxH panel mm 1035x1035x90 Net Gross...

Page 10: ...gn pressure MPa 4 3 1 7 Refrigerant piping Liquid side Gas side mm inch 9 52 15 9 3 8 5 8 Max refrigerant pipe length m 75 Max difference in level m 30 Ambient temperature Cooling C 15 50 Heating C 15...

Page 11: ...Page 11 3 Dimensional Drawings Indoor Unit Compact Cassette...

Page 12: ...ications Page 12 Super Slim Cassette Model KBtu h Unit A B C D 24 mm 165 80 205 50 inch 6 50 3 15 8 07 1 97 30 36 mm 165 100 245 60 inch 6 50 3 94 9 65 2 36 42 60 mm 165 100 287 60 inch 6 50 3 94 11 3...

Page 13: ...Page 13 Outdoor Unit YDAX 035H 09M25...

Page 14: ...Page 14 YDAX 050H 09M25...

Page 15: ...Page 15 YDAX 070H 09M25...

Page 16: ...Page 16 YDAX 100H 09M25 YDAX 100H 09T35 YDAX 140H 09T35...

Page 17: ...Page 17 YDAX 140H 09T35...

Page 18: ...oor unit Abbreviation Paraphrase Y G Yellow Green Conductor CAP1 Indoor Fan Capacitor FAN1 Indoor Fan L LIVE N NEUTRAL TO CCM Comm Bus Central Controller T1 Indoor Room Temperature T2 Coil Temperature...

Page 19: ...Page 19 12K 18K 24K 55K...

Page 20: ...to connect ALARM but no voltage of the terminal port the power from the ALARM system not from the unit 2 Although design voltage can support higher voltage but we strongly ask you connect the power le...

Page 21: ...the remote switch the unit would be responded the demand within 2 seconds 5 When the remote switch on you can use remote controller wire controller to select the mode what you want when the remote sw...

Page 22: ...s the power supply 3 The fresh motor can not excess 200W or 1A follow the smaller one 4 The new fresh motor will be worked when the indoor fan motor work when the indoor fan mo tor stops the new fresh...

Page 23: ...ind action in heating mode Range 24o C 15o C 8o C According to EEROM setting reserved for special customizing B Micro switch SW2 SW2 1 is for selection of indoor FAN ACTION if room temperature reaches...

Page 24: ...ON 1 2 ON 1 2 ON 1 2 ON 1 2 HEAT COOL COOL SW5 E Micro switch SW5 is for setting mode priority of multi connection Range Heat cool F Micro switch SW6 is for selection of temperature compensation in h...

Page 25: ...9 A B D E F 0 8 4 1 2 3 5 6 7 C 9 A B D E F 0 8 4 1 2 3 5 6 7 C 9 A B D E F 0 8 4 1 2 3 5 6 7 C 9 A B D E F 0 8 4 1 2 3 5 6 7 C 9 A B D E F 0 8 4 1 2 3 5 6 7 C 9 A B D E F 0 8 4 1 2 3 5 6 7 C 9 A B D...

Page 26: ...1 CT2 AC Current Detector COMP Compressor L PRO Low Pressure Switch H PRO High Pressure Switch L PFC Inductor SV 4 Way Valve TRANS Power Transformer TP Exhaust Temperature Sensor T4 Outdoor Ambient Te...

Page 27: ...Page 27 YDAX 035H 09M25 YDAX 050H 09M25...

Page 28: ...Page 28 YDAX 070H 09M25...

Page 29: ...Page 29 YDAX 100H 09M25...

Page 30: ...Page 30 YDAX 100H 09T35 YDAX 140H 09T35...

Page 31: ...ipe Size Diameter mm inch Piping length m ft Elevation m ft Additional Refrigerant Gas Liquid Rated Max Rated Max YDAX 050H 09M25 9 52 3 8 6 35 1 4 5 16 4 25 82 0 10 32 8 12g m 0 13oz ft YDAX 050H 09M...

Page 32: ...Page 32 Model Pipe Size Diameter mm inch Piping length m ft Elevation m ft Additional Refrigerant Gas Liquid Rated Max Rated Max YDAX 070H 09M25 15 9 5 8 9 52 3 8 5 16 4 50 164 0 25 82 24g m 0 26oz ft...

Page 33: ...ping length m ft Elevation m ft Additional Refrigerant Gas Liquid Rated Max Rated Max YDAX 100H 09M25 15 9 5 8 9 52 3 8 YDAX 100H 09T35 15 9 5 8 9 52 3 8 5 16 4 75 246 1 0 30 98 4 24g m 0 26oz ft YDAX...

Page 34: ...Specifications Page 34 7 Air Velocity and Temperature Distributions 12K Discharge Angle 30 Cooling airflow velocity distributions Cooling temperature distributions...

Page 35: ...Specifications Page 35 12K Heating airflow velocity distributions Heating temperature distributions...

Page 36: ...Specifications Page 36 12K Discharge Angle 60 Cooling airflow velocity distributions Cooling temperature distributions...

Page 37: ...Specifications Page 37 12K Heating airflow velocity distributions Heating temperature distributions...

Page 38: ...Specifications Page 38 18K Discharge Angle 30 Cooling airflow velocity distributions Cooling temperature distributions...

Page 39: ...Specifications Page 39 18K Heating airflow velocity distributions Heating temperature distributions...

Page 40: ...Specifications Page 40 18K Discharge Angle 60 Cooling airflow velocity distributions Cooling temperature distributions...

Page 41: ...Specifications Page 41 18K Heating airflow velocity distributions Heating temperature distributions...

Page 42: ...Specifications Page 42 24K Discharge Angle 30 Cooling airflow velocity distributions Cooling temperature distributions...

Page 43: ...Specifications Page 43 24K Discharge Angle 30 Heating airflow velocity distributions Heating temperature distributions...

Page 44: ...Specifications Page 44 24K Discharge Angle 60 Cooling airflow velocity distributions Cooling temperature distributions...

Page 45: ...Specifications Page 45 24K Discharge Angle 60 Heating airflow velocity distributions Heating temperature distributions...

Page 46: ...Specifications Page 46 36K Discharge Angle 30 Cooling airflow velocity distributions Cooling temperature distributions...

Page 47: ...Specifications Page 47 36K Discharge Angle 30 Heating airflow velocity distributions Heating temperature distributions...

Page 48: ...Specifications Page 48 36K Discharge Angle 60 Cooling airflow velocity distributions Cooling temperature distributions...

Page 49: ...Specifications Page 49 36K Discharge Angle 60 Heating airflow velocity distributions Heating temperature distributions...

Page 50: ...Specifications Page 50 48k Discharge Angle 30 Cooling airflow velocity distributions Cooling temperature distributions...

Page 51: ...Specifications Page 51 48k Discharge Angle 30 Heating airflow velocity distributions Heating temperature distributions...

Page 52: ...Specifications Page 52 48k Discharge Angle 60 Cooling airflow velocity distributions Cooling temperature distributions...

Page 53: ...Specifications Page 53 48k Discharge Angle 60 Heating airflow velocity distributions Heating temperature distributions...

Page 54: ...Specifications Page 54 55K Discharge Angle 30 Cooling airflow velocity distributions Cooling temperature distributions...

Page 55: ...Page 55 55K Discharge Angle 30 Heating airflow velocity distributions Heating temperature distributions...

Page 56: ...Specifications Page 56 55K Discharge Angle 60 Cooling airflow velocity distributions Cooling temperature distributions...

Page 57: ...Page 57 55K Discharge Angle 60 Heating airflow velocity distributions Heating temperature distributions...

Page 58: ...90 3 90 3 90 4 19 4 19 4 19 4 19 S T 0 70 0 77 0 84 0 91 0 57 0 64 0 71 0 78 0 51 0 58 0 65 0 72 0 38 0 44 0 50 0 56 PI 0 71 0 71 0 71 0 71 0 70 0 70 0 70 0 70 0 70 0 70 0 70 0 70 0 70 0 70 0 70 0 70...

Page 59: ...32 1 32 1 33 1 33 1 33 1 33 569 15 TC 3 84 3 84 3 87 3 90 4 02 4 02 4 02 4 05 4 12 4 12 4 12 4 12 4 40 4 40 4 40 4 40 S T 0 73 0 84 1 00 1 00 0 58 0 68 0 77 0 98 0 50 0 60 0 70 0 78 0 34 0 42 0 51 0 6...

Page 60: ...45 4 45 4 45 4 45 S T 0 72 0 81 0 89 0 97 0 58 0 66 0 74 0 82 0 51 0 59 0 67 0 75 0 36 0 44 0 51 0 58 PI 2 07 2 07 2 07 2 07 2 08 2 08 2 08 2 08 2 09 2 09 2 09 2 09 2 10 2 10 2 10 2 10 584 15 TC 5 62...

Page 61: ...18 1 18 1 18 1 18 1 18 1 18 20 TC 5 48 5 48 5 48 5 53 5 82 5 82 5 82 5 82 5 99 5 99 5 99 5 99 6 42 6 42 6 42 6 42 S T 0 71 0 80 0 88 0 96 0 58 0 65 0 73 0 81 0 51 0 59 0 66 0 74 0 37 0 44 0 51 0 58 PI...

Page 62: ...9 5 89 5 89 5 89 S T 0 84 0 97 1 00 1 00 0 64 0 76 0 88 1 00 0 54 0 66 0 79 0 90 0 33 0 45 0 56 0 67 PI 2 94 2 94 2 94 2 94 2 95 2 95 2 95 2 95 2 96 2 96 2 96 2 96 2 98 2 98 2 98 2 98 1118 15 TC 7 50...

Page 63: ...4 7 98 7 98 7 98 7 98 8 58 8 58 8 58 8 58 S T 0 78 0 89 1 00 1 00 0 61 0 72 0 83 0 93 0 53 0 63 0 74 0 84 0 34 0 44 0 54 0 63 PI 1 74 1 74 1 74 1 74 1 74 1 74 1 74 1 74 1 73 1 73 1 73 1 73 1 72 1 72 1...

Page 64: ...33 0 45 0 57 0 68 PI 3 49 3 49 3 49 3 49 3 51 3 51 3 51 3 51 3 52 3 52 3 52 3 52 3 55 3 55 3 55 3 55 1530 15 TC 9 40 9 49 9 58 9 67 9 89 9 89 9 89 9 98 10 12 10 12 10 12 10 12 10 76 10 76 10 76 10 76...

Page 65: ...00 2 00 2 00 2 00 1 99 1 99 1 99 1 99 1 99 1 99 1 99 1 99 20 TC 9 14 9 22 9 31 9 40 9 68 9 68 9 68 9 77 9 97 9 97 9 97 9 97 10 72 10 72 10 72 10 72 S T 0 81 0 93 1 00 1 00 0 62 0 74 0 86 0 97 0 54 0 6...

Page 66: ...91 8 91 8 91 8 91 S T 0 79 0 90 1 00 1 00 0 61 0 72 0 83 0 94 0 53 0 64 0 74 0 85 0 34 0 44 0 54 0 64 PI 5 00 5 00 5 00 5 00 5 02 5 02 5 02 5 02 5 03 5 03 5 03 5 03 5 07 5 07 5 07 5 07 1530 15 TC 11...

Page 67: ...86 2 86 2 86 2 86 2 86 2 86 2 86 2 85 2 85 2 85 2 85 20 TC 10 95 10 95 11 07 11 18 11 61 11 61 11 61 11 73 11 96 11 96 11 96 11 96 12 85 12 85 12 85 12 85 S T 0 76 0 86 0 96 1 00 0 60 0 70 0 79 0 89 0...

Page 68: ...91 8 91 8 91 8 91 S T 0 79 0 90 1 00 1 00 0 61 0 72 0 83 0 94 0 53 0 64 0 74 0 85 0 34 0 44 0 54 0 64 PI 5 06 5 06 5 06 5 06 5 09 5 09 5 09 5 09 5 10 5 10 5 10 5 10 5 14 5 14 5 14 5 14 1530 15 TC 11...

Page 69: ...90 2 90 2 90 2 89 2 89 2 89 2 89 2 89 2 89 2 89 2 89 20 TC 10 95 10 95 11 07 11 18 11 61 11 61 11 61 11 73 11 96 11 96 11 96 11 96 12 85 12 85 12 85 12 85 S T 0 76 0 86 0 96 1 00 0 60 0 70 0 79 0 89 0...

Page 70: ...6 10 06 10 06 S T 0 82 0 94 1 00 1 00 0 63 0 74 0 86 0 98 0 54 0 65 0 77 0 88 0 34 0 44 0 55 0 66 PI 5 33 5 33 5 33 5 33 5 35 5 35 5 35 5 35 5 36 5 36 5 36 5 36 5 41 5 41 5 41 5 41 1750 15 TC 12 84 12...

Page 71: ...4 3 04 3 04 3 04 3 04 3 04 3 04 3 04 20 TC 12 48 12 48 12 59 12 71 13 25 13 25 13 25 13 25 13 63 13 63 13 63 13 63 14 63 14 63 14 63 14 63 S T 0 76 0 86 0 96 1 00 0 60 0 69 0 79 0 88 0 52 0 62 0 71 0...

Page 72: ...84 11 84 11 84 S T 0 77 0 88 0 98 1 00 0 60 0 70 0 80 0 90 0 52 0 62 0 72 0 82 0 35 0 44 0 53 0 62 PI 5 90 5 90 5 90 5 90 5 92 5 92 5 92 5 92 5 94 5 94 5 94 5 94 5 99 5 99 5 99 5 99 1750 15 TC 15 02...

Page 73: ...37 3 37 3 36 3 36 3 36 3 36 20 TC 14 61 14 61 14 76 14 90 15 50 15 50 15 50 15 50 15 96 15 96 15 96 15 96 17 14 17 14 17 14 17 14 S T 0 72 0 81 0 89 0 97 0 58 0 66 0 74 0 83 0 51 0 59 0 67 0 75 0 36...

Page 74: ...12 90 12 90 12 90 S T 0 76 0 86 0 96 1 00 0 60 0 69 0 79 0 88 0 52 0 61 0 71 0 80 0 35 0 44 0 52 0 61 PI 6 33 6 33 6 33 6 33 6 35 6 35 6 35 6 35 6 37 6 37 6 37 6 37 6 42 6 42 6 42 6 42 1850 15 TC 16 2...

Page 75: ...62 3 62 3 62 3 62 3 62 3 62 20 TC 15 84 15 84 16 02 16 19 16 79 16 79 16 79 16 79 17 28 17 28 17 28 17 28 18 58 18 58 18 58 18 58 S T 0 72 0 80 0 88 0 96 0 58 0 66 0 74 0 82 0 51 0 59 0 67 0 75 0 36...

Page 76: ...7 0 2 94 2 91 2 91 2 88 1 33 1 38 1 35 1 35 5 6 3 01 2 98 2 98 2 95 1 30 1 31 1 31 1 32 2 8 3 09 3 07 3 04 3 01 1 24 1 25 1 25 1 26 0 0 3 12 3 09 3 07 3 04 1 17 1 18 1 18 1 19 2 8 3 27 3 24 3 21 3 18...

Page 77: ...12 4 07 4 04 4 01 1 77 1 82 1 81 1 82 5 6 4 27 4 22 4 19 4 16 1 73 1 76 1 77 1 79 2 8 4 39 4 33 4 33 4 30 1 68 1 70 1 72 1 73 0 0 4 48 4 42 4 39 4 36 1 63 1 65 1 66 1 67 2 8 4 74 4 68 4 65 4 59 1 59...

Page 78: ...96 5 90 5 85 5 82 2 63 2 72 2 66 2 67 5 6 6 11 6 06 6 00 5 97 2 55 2 57 2 58 2 59 2 8 6 23 6 17 6 14 6 09 2 41 2 42 2 43 2 43 0 0 6 29 6 20 6 17 6 14 2 27 2 27 2 28 2 28 2 8 6 58 6 49 6 43 6 40 2 14...

Page 79: ...37 6 31 6 28 2 63 2 71 2 71 2 73 5 6 6 75 6 70 6 64 6 61 2 59 2 64 2 67 2 69 2 8 7 07 6 99 6 96 6 90 2 54 2 58 2 61 2 63 0 0 7 31 7 19 7 16 7 10 2 48 2 52 2 55 2 57 2 8 7 80 7 68 7 62 7 57 2 45 2 49 2...

Page 80: ...00 8 94 3 94 4 08 4 00 4 02 5 6 9 24 9 16 9 13 9 07 3 83 3 87 3 89 3 90 2 8 9 39 9 27 9 22 9 16 3 65 3 68 3 69 3 70 0 0 9 39 9 27 9 22 9 16 3 46 3 48 3 49 3 50 2 8 9 74 9 62 9 56 9 48 3 30 3 31 3 32 3...

Page 81: ...76 8 73 3 91 4 04 3 97 3 99 5 6 9 08 8 99 8 93 8 91 3 80 3 84 3 86 3 88 2 8 9 25 9 14 9 08 9 02 3 62 3 65 3 66 3 67 0 0 9 28 9 17 9 11 9 05 3 43 3 45 3 46 3 47 2 8 9 69 9 54 9 49 9 43 3 28 3 29 3 29 3...

Page 82: ...3 88 4 00 4 00 4 03 5 6 9 79 9 67 9 62 9 56 3 83 3 91 3 95 3 99 2 8 10 23 10 11 10 02 9 96 3 76 3 83 3 87 3 91 0 0 10 55 10 40 10 31 10 25 3 69 3 76 3 79 3 83 2 8 11 24 11 10 11 01 10 92 3 65 3 72 3...

Page 83: ...12 25 5 40 5 58 5 52 5 55 5 6 12 81 12 67 12 61 12 55 5 29 5 36 5 40 5 44 2 8 13 10 12 96 12 87 12 81 5 10 5 17 5 20 5 24 0 0 13 25 13 08 12 99 12 93 4 91 4 97 5 00 5 03 2 8 13 86 13 68 13 60 13 51 4...

Page 84: ...13 16 5 71 5 89 5 89 5 95 5 6 13 94 13 80 13 71 13 62 5 65 5 77 5 83 5 89 2 8 14 38 14 20 14 12 14 03 5 56 5 67 5 73 5 79 0 0 14 64 14 44 14 35 14 26 5 47 5 58 5 63 5 69 2 8 15 42 15 22 15 13 15 02 5...

Page 85: ...8 0 970 0 1 000 0 993 0 978 0 970 Outdoor Upper than Indoor 5 0 992 0 985 0 970 0 962 10 0 977 0 962 0 955 Capacity Btu h 18K Pipe Length m Cooling 5 10 20 30 Height difference H m Indoor Upper than O...

Page 86: ...n Indoor 5 1 000 0 989 0 968 0 947 0 926 0 905 10 0 989 0 968 0 947 0 926 0 905 20 0 968 0 947 0 926 0 905 25 0 947 0 926 0 905 Heating 5 10 20 30 40 50 Height difference H m Indoor Upper than Outdoor...

Page 87: ...n Indoor 5 1 000 0 984 0 951 0 919 0 886 0 854 10 0 984 0 951 0 919 0 886 0 854 20 0 951 0 919 0 886 0 854 25 0 919 0 886 0 854 Heating 5 10 20 30 40 50 Height difference H m Indoor Upper than Outdoor...

Page 88: ...945 0 917 0 876 0 834 0 806 10 0 972 0 945 0 917 0 876 0 834 0 806 20 0 945 0 917 0 876 0 834 0 806 30 0 917 0 876 0 834 0 806 Heating 5 15 25 35 50 65 75 Height differ ence H m Indoor Upper than Out...

Page 89: ...942 0 913 0 870 0 826 0 797 10 0 971 0 942 0 913 0 870 0 826 0 797 20 0 942 0 913 0 870 0 826 0 797 30 0 913 0 870 0 826 0 797 Heating 5 15 25 35 50 65 75 Height differ ence H m Indoor Upper than Out...

Page 90: ...941 0 912 0 868 0 824 0 795 10 0 971 0 941 0 912 0 868 0 824 0 795 20 0 941 0 912 0 868 0 824 0 795 30 0 912 0 868 0 824 0 795 Heating 5 15 25 35 50 65 75 Height differ ence H m Indoor Upper than Out...

Page 91: ...Data is valid at free field condition Data is valid at nominal operation condition Reference acoustic pressure OdB 20 Pa Sound level will vary depending on a range of factors such as theconstruction a...

Page 92: ...Specifications Page 92 12k 18k 24k 30k...

Page 93: ...Specifications Page 93 36k 42k 48k 55k...

Page 94: ...d condition Data is valid at nominal operation condition Reference acoustic pressure OdB 20 Pa Sound level will vary depending on arrange off actors such as the construction acoustic absorption coeffi...

Page 95: ...Page 95 YDAX 070H 09M25 YDAX 100H 09M25 YDAX 100H 09T35...

Page 96: ...Page 96 YDAX 140H 09T35...

Page 97: ...0 4x2 5 with auxiliary electric heater 4 1 0 4x2 5 with auxiliary electric heater 4 1 0 4x2 5 with auxiliary electric heater 4 1 0 4x2 5 with auxiliary electric heater Capacity Btu h 36k 42k 48 55k OU...

Page 98: ...d operation Function 102 1 10 Timer Function 102 1 11 Sleep Function 102 1 12 Auto Restart 103 1 13 8 C Heating 103 1 14 Follow Me 103 1 15 Silence 103 1 16 ECO 103 1 17 Electrical energy consumption...

Page 99: ...n When the unit starts the louver is automatically activated and the indoor fan will operate after a period of setting time or the louver is in place If the unit is in heating mode the indoor fan is r...

Page 100: ...gh and auto 2 Auto fan action in cooling mode Descent curve When T1 Tsc is lower than or equal to 3 5 C fan speed reduces to 80 When T1 Tsc is lower than or equal to 1 C fan speed reduces to 60 When T...

Page 101: ...1 Tsc is higher than 0 5 C fan speed reduces to 40 When T1 Tsc is higher than 1 C fan speed reduces to 20 Descent curve When T1 Tsc is lower than or equal to 0 5 C fan speed increases to 20 When T1 Ts...

Page 102: ...ature of 24 C 76 F Forced auto mode Forced auto mode operates the same as normal auto mode with a preset temperature of 24 C 76 F The unit exits forced operation when it receives the following signals...

Page 103: ...e remote controller will adjust the temperature automatically to 24 C 75 F fan speed of Auto to save energy but only if the set temperature is less than 24 C 75 F If the set temperature is more than 2...

Page 104: ...roller Functions 2 1 Infrared Wireless Remote Controller 2 1 1 Remote Controller Specifications Model Rated Voltage 3 0V Dry batteries R03 LR03 2 Reaching Distance 8m Environment Temperature Range 5 C...

Page 105: ...Product Features Page 105 Remote LCD Screen Indicators...

Page 106: ...F You can increase or decrease the set temperature in 0 5O C 1O F increments AUTO Operation In AUTO mode the unit will automatically select the COOL FAN HEAT or DRY mode based on the set temperature...

Page 107: ...ected symbol will flash on the display area press the OK button to confirm To cancel the selected function just perform the same procedures as above Press the SET button to scroll through operation fu...

Page 108: ...d buttons together for 3 seconds will alternate the temperature display between the O C O F scale FP Function When the air conditioner operates under heating mode with the set temperature of 16O C 60O...

Page 109: ...system to its default settings Used to start stop the air conditioner Press these two buttons at the same time to switch between Celsius and Fahrenheit some models The SWING button starts and stops th...

Page 110: ...door unit 5 Core Shield Cable Wire Joint 5p Infrared Pipe Indoor Unit RUN GND 5V Indoor Unit Switch Board Wir e Con troll er Installation Diagram Connect the wire from the display panel of the indoor...

Page 111: ...to seal the wires For exposed mounting cut holes on four of the sides according to the picture below Cut three holes for wire outlet Cut one holes for wire outlet For shielded wiring please refer to...

Page 112: ...to previous operation or superior menu 12 COPY button Copy timer setting of one day to another in weekly schedule setting 13 Infrared remote receiver on some models 1 POWER button Turn on of turn off...

Page 113: ...ock indication 12 Room temperature indication 13 Clock display 14 On Off timer 15 Timer display 1 Operation mode indication 2 Fan speed indication 3 Left right swing indication 4 Up down swing indicat...

Page 114: ...Insert of the mainboard CN40 Wire controller Indoor unit mainboard 4 Core Shield Cable the length is decided by installation Installation Diagram Connect the female joint of wires group from the mainb...

Page 115: ...e wires For exposed mounting four outletting positions There are three need cutting Cutting place of top side wire outlet Cutting place of left side wire outlet Cutting place of right side wire outlet...

Page 116: ...t up or down the auto lifting panel 4 FAN SPEED button Usedtoselect the fan speed 5 Swing Button Press to active vertical swing hold for horizontal swing 6 TIMER button To set timer on and timer off t...

Page 117: ...ication 4 Up down swing indication 5 Faceplate function indication 6 Main unit and secondary unit indication 7 Follow me function indication 8 Turbo PTC function indication 9 C F indication 10 Tempera...

Page 118: ...controller connects to main control board directly HA HB HA HB Main control board Wired controller ADSS 01 2 3 4 5 6 7 8 9 A B C D EF For some models Ceiling floor The wired controller connects to ter...

Page 119: ...ed to several units every air conditioner in network has only one network address to distinguish each other c Address code of air conditioner in LAN is set by code switch ENC1 Duct and Ceiling Floor o...

Page 120: ...indoor unit there are three methods From the rear From the bottom From the top From the top center PCB PCB PCB PCB HA HB 1 2 HA HB HA HB 2 HA HB 1 2 1 2 3 4 1 Indoor Unit 2 Notch the part for the wir...

Page 121: ...ole day off in a weekly timer schedule 4 Adjust button To set temperature time and timer 5 CONFIRM button To confirm an setting or call up the superior menu 6 TIMER button To set timer on and timer of...

Page 122: ...ndication 3 Temperature display 4 Lock indication 5 C F indication 6 Main unit and secondary unit indication 7 Turbo function indication 8 Room temperature indication 9 Rotating indication 10 Follow M...

Page 123: ...x A B 1 Indoor Unit 2 Notch the part for the wiring to pass through with a nipper tool Connect the terminals on the remote controller HA HB and the terminals of the indoor unit HA HB HA and HB do not...

Page 124: ...s b When the non polarity controller is connected to several units every air conditioner in network has only one network address to distinguish each other c Address code of air conditioner in LAN is s...

Page 125: ...powered off The address can be set from 0 to 63 by the switch Turn on the unit then the address will be effective Note For light commercial aire conditioner with XYE port it can be also connected to B...

Page 126: ...Outdoor Unit Installation 132 5 Drainage Pipe Installation 133 6 Refrigerant Pipe Installation 135 7 Vacuum Drying and Leakage Checking 137 8 Additional Refrigerant Charge 138 9 Engineering of Insula...

Page 127: ...1 Drain joint some models 1 Seal ring some models 1 Remote controller Its Frame some models Remote controller 1 Fixing screw for remote controller holder ST2 9 x 10 2 Remote controller holder 1 Dry b...

Page 128: ...ew Installation Order L N 1 2 3 4 5 MC MC 6 7 8 Install the indoor unit Install the outdoor unit Install the drainpipe Evacuate the refrigeration system Connect the wires Connect the refrigerant pipes...

Page 129: ...minimum distance between the outdoor unit and walls described in the installation guide does not apply to airtight rooms Be sure to keep the unit unobstructed in at least two of the three directions M...

Page 130: ...inch B mm inch 24 205 8 07 230 9 06 900 35 4 30 36 245 9 65 271 10 7 42 55 287 11 3 313 12 3 3 2 Hang Indoor Unit 1 Use the included paper template to cut a rectangular hole in the ceiling leaving at...

Page 131: ...re it Insert suspension bolts into the unit s hang ing holes Fasten them using the included washers and nuts Adjust the position to ensure the gaps between the indoor unit and the four sides of false...

Page 132: ...emplate onto the unit with bolts M6X12 to determine in advance the dimension and position of the opening on the ceiling Follow the instructions above for the remainder of the installation 4 Outdoor un...

Page 133: ...er pipe installation 1 Considering the pipeline route and elevation Before installing condensate water pipeline deter mine its route and elevation to avoid intersection with other pipelines and ensure...

Page 134: ...shall cre ate bending thus leading to air block 5 The horizontal pipe layout should avoid converse flow or bad flow The correct installation will not cause converse water flow and the slope of the br...

Page 135: ...0 164 25 82 36 60 75 246 1 30 98 4 Caution 1 The capacity test is based on the standard length and the maximum permissive length is based on the system reliability 2 Oil traps If oil flows back into t...

Page 136: ...if the pipes need to pass the wall 8 According to the field condition to bend the pipes so that it can pass the wall smoothly 9 Bind and wrap the wire together with the insulated pipe if necessary 10...

Page 137: ...hours of drying check whether there is leakage source 4 Leakage test After the vacuum degree reaches 755mmHg stop vacuum drying and keep the pressure for 1 hour If the indicator of vacuum gauge does n...

Page 138: ...e suitable pipe insulation except joint section flare the pipe piping layout and connection vacuum drying insulate the joint parts 2 Purpose of refrigerant pipe insulation During operation temperature...

Page 139: ...en the insulation material 10 Engineering of Electrical Wiring 1 Highlights of electrical wiring installation All field wiring construction should be finished by qualified electrician Air conditioning...

Page 140: ...anel hook screws evenly at the four corners Note Tighten the screws until the thickness of the sponge between the main body and the panel reduces to 4 6mm 0 2 0 3 The edge of the panel should be in co...

Page 141: ...asteners into the corresponding slots on the panel NOTE After installation the butt plugs of display swing water pump and other wire bodies must be placed in the electric control box 11 2 Compact Cass...

Page 142: ...properly connected The length of the piping and the added refrigerant stow capacity have been recorded The power voltage is the correct voltage for the air conditioner CAUTION Failure to perform the t...

Page 143: ...urn on the main power switch and run the air conditioner in COOL mode d Listen to the sound of the drain pump to see if it makes any unusual noises e Check to see that the water is discharged It may t...

Page 144: ...lt with the sales agency or manufacturer for details ATTENTION Le design et les donn es techniques sont donn s titre indicatif et peuvent tre modifi s sans pr avis AIRWELL RESIDENTIAL SAS 10 Rue du Fo...