4.3 Micro-Switch introduce:
A.
Micro-switch SW1 is for selection of indoor fan stop temperature (TEL0) when it is in anti-cold
wind action in heating mode.
Range: 24
o
C, 15
o
C, 8
o
C, According to EEROM setting (reserved for special customizing).
B.Micro-switch SW2/SW2-1 is for selection of indoor FAN ACTION if room temperature reaches the
setponit and the compressor stops.
Range: OFF (anti-cold wind is available in heating mode), Keep running (No anti-cold wind function).