Use and maintenance manual Self-propelled aerial platforms Page 28
5.2.1.5
User interface display (E)
The multifunction display for machine/user interface is used to:
-
Display the operation parameters of the machine during normal functioning or in the event of a fault;
-
Working hours of Diesel engine (when Diesel power is selected the working hours are displayed in the format
HOURS:MINUTES and final letter D);
-
Working hours of the work pump (when electric power is selected the working hours are displayed in the format
HOURS:MINUTES and final letter E);
-
Charge level of the battery (only electrical models E).
The user interface display is also used during any interventions by specialized personnel to
calibrate/adjust the working parameters of the machine. This function is not available to the user.
5.2.1.6
Battery charger warning light (F- Electric and Electric/diesel models only)
Electric power and bi-fuel models (“E”, “E/D” and “E/B”), equipped with a built-in high frequency battery charger, are provided
with this warning light indicating the operation of the battery charger (for more detailed information read the paragraph:
“Battery charge”).
5.2.1.7
Warning light: machine on (G)
The green light is on with machine on with ground controls only.
5.2.1.8
Diesel engine warning lights (G-H-L-M-N)
These warning lights warn the user of any Diesel engine operational faults (models “D” and “E/D”). One of these warning
lights turns ON when the engine is stopped. A “fault” message is sent to the operator on the platform (see paragraph “Platform
control panel”).
Once the Diesel engine has stopped due to a problem signalled by one of these warning lights, the engine can no longer be
re-started until such problem has been solved.
5.2.1.9
Platform control levers (O-P-Q-R)
The various levers shown in the figure allow the platform to be operated. According to the various signs the corresponding
movements are activated. These controls can be operated only if the on-off key is set to ON downwards (ground control
station selected). We shall also remind you that the ground controls are to be used to operate the platform only in emergency
situations and must not be used for any other purposes.
Use the ground controls only in emergency situations to allow the platform to be recovered.
IT IS FORBIDDEN to use the ground control station as a workstation when personnel is on the
platform.