Use and maintenance manual Self-propelled aerial platforms Page 16
4
INSTALLATION AND PRELIMINARY CHECKS
The machine is supplied completely assembled, therefore it can perform all functions in full safety as provided for by the
manufacturer. No preliminary operation is required. To unload the machine, follow the instructions in paragraph “Handling and
carrying”.
Place the machine onto a firm ground and with a gradeability lower than the max. allowed (see “Stability limits”). The machine
is equipped with on-platform spirit levels for visual check and an inclinometer on the chassis to always check machine
levelling, both transversal and longitudinal.
Before using the machine read the instructions given in this manual and the concise instructions indicated on the platform
plate.
Before starting any operations verify the integrity of the unit (by means of a visual check) and read the plates indicating the
operating limits.
For safety reasons "-
B/G
" series machines are delivered without LPG cylinder or with cylinder completely empty. To install the
cylinder read the instructions provided in this manual. Use cylinders complying with the maximum dimensions indicated in
chapter "Technical features". After installing the LPG cylinder, before using the machine, check for correct fixing and stability
of the cylinder and make sure there are is no leakage from the gas feeding tubes. The refilling of empty cylinders must be
performed by specialised personnel.
4.1
Before using the machine
Before using the machine the operator must always check visually that:
-
the battery is completely charged;
-
the oil level lies between the min. and max. value (with lowered platform);
-
the machine carries out all operations in safety;
-
the wheels and drive engines are properly fixed;
-
the wheels are in good condition;
-
the guardrails are fixed to the platform and the self-closing gates are present;
-
the structure does not show clear faults (check welding of lifting structure);
-
the instructions plates are perfectly readable;
-
the controls are perfectly efficient both at platform and at emergency ground control station, including the “dead-man”
system.