background image

 

 

Page 8 of 8 

 

Germany 

AIRFLOW LUFTTECHNIK GmbH 
Postfach 1208 
D-53349 Rheinbach 
Germany 
 
Tel: 

+49 (0) 222 69205 0 

Fax: 

+49 (0) 222 69205 11 

Email:   [email protected] 
Web: 

airflow.de

 

Czech Republic 

AIRFLOW LUFTTECHNIK GmbH 
o.s. Praha 
Hostýnská 520 
108 00 Praha 10 
Malešice 
Czech Republic 
 

 

Tel: 

+42 (0) 2 7477 2230 

Fax: 

+42 (0) 2 7477 2370 

Email:  info@airflow.cz 
Web: 

airflow.cz 

UK  Head-Office 

AIRFLOW DEVELOPMENTS Limited 
Aidelle House, Lancaster Road 
Cressex Business Park 
High Wycombe 
Buckinghamshire  
HP12 3QP 
United Kingdom 
 
Tel: 

+44 (0) 1494 525252 

Fax: 

+44 (0) 1494 461073 

Email:  [email protected] 
Web: 

airflow.com 

AIRFLOW DEVELOPMENTS Limited reserve the right in the interest of continuous development to alter any or all specifications without prior notice. 

 

Range of Optional Modules Available 
 

Choose the 230V Module 
PCM – Pull Cord: 

72573602/B 

TM – Adjustable Timer:

 72612601/B 

HTM – Humidity, Pull cord with Timer Overrun: 

72573902/B

 

PRTM – Passive Infra Red with Timer Overrun: 

72573903/B

 

PRHTM – Passive Infra Red/Humidity/Timer: 

72573901/B 

CVM30 – Continuous Ventilation iCON30:

 72631802 

CV2 – Continuous Ventilation:

 72675701B

 

DTM – Delayed Timer start AC: 

7265702B 

2SHM – 2 Speed /Humidity/ Pull Cord boost AC:

 72675703B

 

 
 

Choice of Anthracite, Sandstone, Chrome and Silver covers 

 
 
 
 
 
 
 
 
 

iCON 15 cover Anthracite

    52634503B 

 

iCON 30 cover Silver   

52634507B 

iCON 15 cover Silver

    

52634504B 

 

iCON 30 cover Sandstone 

52634508B 

iCON 15 cover Sandstone

    52634505B 

 

iCON 60 cover Anthracite 

52634509B 

iCON 15 cover Chrome

  

52634502B 

 

iCON 60 cover Silver   

52634510B 

iCON 30 cover Anthracite

  

52634506B 

 

iCON 60 cover Sandstone 

52634511B 

 

 

 
 

 

 

 

 

 
 

 

9041548 

Issue 3 

01/12  

Summary of Contents for iCON eco15

Page 1: ...Domestic AC Fans 230V Installation and Operating Guide eco 230V AC Base Models iCON eco15 72683501 iCON15 72591501 iCON30 72591601 iCON60 72591701 ...

Page 2: ...th maximum capacity of 72 l sec The iCON range can be used as a simple extract fan operated by a remote switch or can be fitted with an internal control module available separately to give a range of control options including timer humidity motion sensor pull cord trickle speed or combinations of these functions Optional modules are available separately and can be fitted at the time of installatio...

Page 3: ...r ceiling A mounting skirt is provided for surface mounting the iCON 30 and iCON 60 To avoid the backflow of condensation into the fan in a ceiling installation it is good practice to fit a CONDENSATION TRAP to the outlet duct of the fan Ensure free running of the fan impeller and that flexible duct connections are not over tightened to the fan outlet spigot Airflow recommend that rigid ducting is...

Page 4: ... of 75mm The hole should be lined with 150mm id duct Surface Mounting Fans on the Wall When surface mounting the iCON30 and iCON60 the supplied mounting skirt should be used The iCON30 requires a 110mm diameter hole through the wall lined with a 100 mm id duct and the iCON60 requires a 160mm diameter hole through the wall lined with a 150 mm id duct Recessing Fans in the Ceiling When recessing fan...

Page 5: ...face Mounting Fans on the Ceiling When surface mounting the iCON30 the mounting skirt should be used The iCON30 requires a 110mm diameter hole through the ceiling and the iCON60 a 170mm diameter hole The surface mounted skirt to be fixed with the screws provided through the plaster board into the support The fan is then fitted into the skirt Where flexible duct is used the diameter must be maintai...

Page 6: ...Domestic Fans require a 230V 50Hz supply it is double insulated so therefore does not require an earth For fans mounted in Zones 1 2 as defined in section 701 BS7161 2008 Additional protection must be provided by a Residual current device RCD with a rated residual operating current not exceeding 30mA Wiring with no control module fitted Optional Modules for iCON and iCON eco 230V Wiring for contro...

Page 7: ...ter approximately 15 minutes and will restart the fan when reconnected to the module controller and mains supply Warranty Applicable to units installed and used in the United Kingdom Airflow guarantees the iCON iCON eco fan units and iCON modules for 2 YEARS from date of purchase against faulty material or workmanship Extended to 3 when registered airflow com Warranty only covers the fan not the r...

Page 8: ...l specifications without prior notice Range of Optional Modules Available Choose the 230V Module PCM Pull Cord 72573602 B TM Adjustable Timer 72612601 B HTM Humidity Pull cord with Timer Overrun 72573902 B PRTM Passive Infra Red with Timer Overrun 72573903 B PRHTM Passive Infra Red Humidity Timer 72573901 B CVM30 Continuous Ventilation iCON30 72631802 CV2 Continuous Ventilation 72675701B DTM Delay...

Reviews: