background image

 

41893-01 • 08/29/05 

Summary of Contents for 23721

Page 1: ...41893 01 08 29 05 ...

Page 2: ...h location If you cannot lock the circuit breakers in the off position securely fasten a prominent warning device such as a tag to the service panel All wiring must be in accordance with national and local electrical codes and ANSI NFPA 70 If you are unfamiliar with wiring use a qualified electrician To reduce the risk of personal injury do not bend the blade attachment system when installing bala...

Page 3: ... Consider using Hunter s optional accessories including a wall mounted or remote speed control To install and use the accessories follow the instructions included with each product For quiet and optimum performance of your Hunter fan use only Hunter speed controls Low Profile Mounting fits close to the ceiling recommended for ceilings less than 8 feet high Standard Mounting hangs from the ceiling ...

Page 4: ...YourFanParts Carefully unpack your fan to avoid damage to the fan parts Check for any shipping damage to the motor or fan blades If one of the fan blades was damaged in shipment return all the blades for replacement If any parts are missing or damaged contact your Hunter dealer or call Hunter Parts Department at 888 830 1326 PreparingtheFanSite Before you begin installing the fan follow all the in...

Page 5: ...e slotted holes in the ceiling plate with the pilot holes you drilled in the wood support structure For proper alignment use slotted holes directly across from each other Note e isolators should be flush against the ceiling 2 5 Place a flat washer on each of the two 3 screws and pass the screws through the slotted holes in the ceiling plate into the pilot holes you drilled Tighten the screws into ...

Page 6: ...etighten the set screw with a wrench or pliers Skip to Step 3 5 CAUTION e adapter has a special coating on the threads Do not remove this coating the coating prevents the downrod from unscrewing Once assembled do not remove the downrod 3 3 Place the low profile washer lip up into the canopy Be sure the green ground wire is pointing up toward the ceiling Note For low profile mounting the downrod is...

Page 7: ...p 4 4 4 3 If you want to you can control the fan and light separately using two wall switches connect the wires as follows connect the green ground wire to the ground wire connect white wire to white wire connect black wire to black wire and connect the black white wire from the fan to the wire for the wall switch 4 4 Alternatively you can control both fan and light with one switch To do so connec...

Page 8: ...osely assemble the three canopy screws into the canopy one at a time Once all three screws are in tighten them 5 5 Using both hands push the canopy trim ring up to the top of the canopy e canopy trim ring will snap and lock into place Should you need to remove the canopy trim ring follow these steps 1 Locate the tab indicators small bumps on top of tabs 2 Press firmly on opposite sides of the ring...

Page 9: ...ade assembly screws If you used grommets the blades may appear slightly loose after screws are tightened is is normal 6 3 Remove the blade armature screws and rubber shipping bumpers from the motor Save the screws for the following step and discard the shipping bumpers 6 4 For each blade insert one blade armature screw through the blade iron and attach lightly to the fan Insert the second blade ar...

Page 10: ...sing Tighten all three screws firmly CAUTION Make sure the upper switch housing is securely attached to the switch housing mounting plate Failure to properly attach and tighten all three assembly screws could result in the switch housing falling 7 6 Connect the plug connectors Note Both plug connectors are polarized and will only fit together one way Make sure the connectors are properly aligned b...

Page 11: ...bute the warmer air trapped at the ceiling around the room without causing a draft 8 5 For cleaning finishes use a soft brush or lint free cloth to prevent scratching A vacuum cleaner brush nozzle can remove heavier dust Remove surface smudges or accumulated dirt and dust using a mild detergent and a slightly dampened cloth You may use an artistic agent but never abrasive cleaning agents as they w...

Page 12: ...6 Remove the shipping bumpers Problem Noisy operation 1 Tighten the blade bracket screws until snug 2 Check to see if the blade is cracked If so replace all the blades Problem Excessive wobbling 1 If your fan wobbles when operating use the enclosed balancing kit and instructions to balance the fan 2 Tighten all blade iron screws 3 Turn power off support fan very carefully and check that the hanger...

Reviews: