background image

 

 

Page 7 of 8 

 

 

 

Maintenance 

SAFETY FIRST: ALWAYS ISOLATE THE FAN UNIT FROM THE POWER SUPPLY BEFORE 
REMOVING THE COVER. 

 

Warranty only covers the fan, not the reinstallation of this if required. 
When installed according to these instructions the iCON Domestic Fans are completely safe.  
The materials used do not constitute a hazard.  The module covers are made of a flame 
retardant material.

 

Cleaning 

 

The external housing of the fan can be wiped with a damp cloth.  Do not use household 
cleaners containing abrasives.

 

 

Cleaning of the internal parts such as the impeller should be carried out using a soft 
brush.   

Note: 

Always ensure that the fan unit is isolated from the power supply before inserting 

the brush into the impeller duct.

 

 

Never clean any parts of the fan assembly by immersing in water or using a dishwasher. 

 

Trouble shooting Tip:

 

 

Take care not to over tighten the duct connection to the fan spigot. This can result in 
restricting the free rotation of the impeller and a thermal overload of the motor could occur 
causing short term fan failure. In the event of this occurring loosen the duct connection so 
that the impeller rotates freely within the spigot. 
The motor is fitted with an automatic reset after approximately 15 minutes and will restart 
the fan when reconnected to the module controller and mains supply. 

 

Warranty 

Applicable to units installed and used in the United Kingdom.  Airflow guarantees the iCON, 
iCON  eco  fan  units  and  iCON  modules  for  2  YEARS  from  date  of  purchase  against  faulty 
material  or  workmanship.  Extended  to  3  when  registered  @  airflow.com.  Warranty  only 
covers the fan, not the reinstallation of this if required. 
In the event of any defective parts being found, Airflow Developments Ltd reserve the right 
to repair or at our discretion replace without charge provided that the unit: 

1.

 

Has been installed and used in accordance with the fitting and wiring instructions 
supplied with each unit. 

2.

 

Has not been connected to an unsuitable electrical supply. 

3.

 

Has not been subjected to misuse, neglect or damage. 

4.

 

Has not been modified or repaired by any person not authorised by Airflow 
Developments Ltd 

5.

 

Has been installed in accordance with latest Building Regulations and IEEE wiring 
regulations. 

Airflow Developments shall not be liable for any loss, injury or other consequential damage, 
in the event of a failure of the equipment or arising from, or in connection with, the 
equipment excepting only that nothing in this condition shall be construed as to exclude or 
restrict liability for negligence. 
 

This warranty does not in any way affect any statutory or other consumer rights.

 

 

Summary of Contents for iCON eco15

Page 1: ...Domestic AC Fans 230V Installation and Operating Guide eco 230V AC Base Models iCON eco15 72683501 iCON15 72591501 iCON30 72591601 iCON60 72591701 ...

Page 2: ...th maximum capacity of 72 l sec The iCON range can be used as a simple extract fan operated by a remote switch or can be fitted with an internal control module available separately to give a range of control options including timer humidity motion sensor pull cord trickle speed or combinations of these functions Optional modules are available separately and can be fitted at the time of installatio...

Page 3: ...r ceiling A mounting skirt is provided for surface mounting the iCON 30 and iCON 60 To avoid the backflow of condensation into the fan in a ceiling installation it is good practice to fit a CONDENSATION TRAP to the outlet duct of the fan Ensure free running of the fan impeller and that flexible duct connections are not over tightened to the fan outlet spigot Airflow recommend that rigid ducting is...

Page 4: ... of 75mm The hole should be lined with 150mm id duct Surface Mounting Fans on the Wall When surface mounting the iCON30 and iCON60 the supplied mounting skirt should be used The iCON30 requires a 110mm diameter hole through the wall lined with a 100 mm id duct and the iCON60 requires a 160mm diameter hole through the wall lined with a 150 mm id duct Recessing Fans in the Ceiling When recessing fan...

Page 5: ...face Mounting Fans on the Ceiling When surface mounting the iCON30 the mounting skirt should be used The iCON30 requires a 110mm diameter hole through the ceiling and the iCON60 a 170mm diameter hole The surface mounted skirt to be fixed with the screws provided through the plaster board into the support The fan is then fitted into the skirt Where flexible duct is used the diameter must be maintai...

Page 6: ...Domestic Fans require a 230V 50Hz supply it is double insulated so therefore does not require an earth For fans mounted in Zones 1 2 as defined in section 701 BS7161 2008 Additional protection must be provided by a Residual current device RCD with a rated residual operating current not exceeding 30mA Wiring with no control module fitted Optional Modules for iCON and iCON eco 230V Wiring for contro...

Page 7: ...ter approximately 15 minutes and will restart the fan when reconnected to the module controller and mains supply Warranty Applicable to units installed and used in the United Kingdom Airflow guarantees the iCON iCON eco fan units and iCON modules for 2 YEARS from date of purchase against faulty material or workmanship Extended to 3 when registered airflow com Warranty only covers the fan not the r...

Page 8: ...l specifications without prior notice Range of Optional Modules Available Choose the 230V Module PCM Pull Cord 72573602 B TM Adjustable Timer 72612601 B HTM Humidity Pull cord with Timer Overrun 72573902 B PRTM Passive Infra Red with Timer Overrun 72573903 B PRHTM Passive Infra Red Humidity Timer 72573901 B CVM30 Continuous Ventilation iCON30 72631802 CV2 Continuous Ventilation 72675701B DTM Delay...