iCON Domestic Fans are available in 3 model sizes and can be fitted to a wall or ceiling. Each 
fan requires a suitable size hole through the wall or ceiling which connects into a duct 
venting to the outside. The external opening should be covered by a suitable external grill, 
available separately from Airflow Developments Ltd. 
 
Airflow iCON / iCON eco Model Options 
 
72683501 - eco15   -100mm Axial Fan with maximum capacity of 18.6 l/sec. 
72573602 - 15          -100mm Axial Fan with maximum capacity of 21 l/sec. 
72591601 - 30          -100mm Mixed Flow Fan with maximum capacity of 32 l/sec 
72591701 - 60          -150mm Mixed Flow Fan with maximum capacity of 72 l/sec 
 
The iCON range can be used as a simple extract fan operated by a remote switch, or can be 
fitted with an internal control module, available separately to give a range of control options 
including timer, humidity, motion sensor, pull cord, trickle speed or combinations of these 
functions. Optional modules are available separately and can be fitted at the time of 
installation or retrofitted.  
 
The iCON Fan has an IP X4 rating housing and is suitable for mounting in Zone 1 or 2 in 
bathrooms, toilets, kitchens, utility rooms and inside shower cubicles as defined in Section 
701 BS7161:2008 (IEEE wiring standards, 17

th

 Edition ).  They also comply with the latest 

Building Regulations. 
 

Do not place the ventilator near direct heat sources, e.g. radiant heaters,

 

or where 

temperatures can exceed 40°C (104°F). 

 
iCON Domestic Fan – 230V 

Summary of Contents for iCON eco15

Page 1: ...Domestic AC Fans 230V Installation and Operating Guide eco 230V AC Base Models iCON eco15 72683501 iCON15 72591501 iCON30 72591601 iCON60 72591701 ...

Page 2: ...th maximum capacity of 72 l sec The iCON range can be used as a simple extract fan operated by a remote switch or can be fitted with an internal control module available separately to give a range of control options including timer humidity motion sensor pull cord trickle speed or combinations of these functions Optional modules are available separately and can be fitted at the time of installatio...

Page 3: ...r ceiling A mounting skirt is provided for surface mounting the iCON 30 and iCON 60 To avoid the backflow of condensation into the fan in a ceiling installation it is good practice to fit a CONDENSATION TRAP to the outlet duct of the fan Ensure free running of the fan impeller and that flexible duct connections are not over tightened to the fan outlet spigot Airflow recommend that rigid ducting is...

Page 4: ... of 75mm The hole should be lined with 150mm id duct Surface Mounting Fans on the Wall When surface mounting the iCON30 and iCON60 the supplied mounting skirt should be used The iCON30 requires a 110mm diameter hole through the wall lined with a 100 mm id duct and the iCON60 requires a 160mm diameter hole through the wall lined with a 150 mm id duct Recessing Fans in the Ceiling When recessing fan...

Page 5: ...face Mounting Fans on the Ceiling When surface mounting the iCON30 the mounting skirt should be used The iCON30 requires a 110mm diameter hole through the ceiling and the iCON60 a 170mm diameter hole The surface mounted skirt to be fixed with the screws provided through the plaster board into the support The fan is then fitted into the skirt Where flexible duct is used the diameter must be maintai...

Page 6: ...Domestic Fans require a 230V 50Hz supply it is double insulated so therefore does not require an earth For fans mounted in Zones 1 2 as defined in section 701 BS7161 2008 Additional protection must be provided by a Residual current device RCD with a rated residual operating current not exceeding 30mA Wiring with no control module fitted Optional Modules for iCON and iCON eco 230V Wiring for contro...

Page 7: ...ter approximately 15 minutes and will restart the fan when reconnected to the module controller and mains supply Warranty Applicable to units installed and used in the United Kingdom Airflow guarantees the iCON iCON eco fan units and iCON modules for 2 YEARS from date of purchase against faulty material or workmanship Extended to 3 when registered airflow com Warranty only covers the fan not the r...

Page 8: ...l specifications without prior notice Range of Optional Modules Available Choose the 230V Module PCM Pull Cord 72573602 B TM Adjustable Timer 72612601 B HTM Humidity Pull cord with Timer Overrun 72573902 B PRTM Passive Infra Red with Timer Overrun 72573903 B PRHTM Passive Infra Red Humidity Timer 72573901 B CVM30 Continuous Ventilation iCON30 72631802 CV2 Continuous Ventilation 72675701B DTM Delay...