24
DV50 DV80
(Integral CO
2
Sensor)
VENTILATION PROFILES
USING THE UNIT
MODIFYING THE BOOST PROFILE SETTINGS
When you want to edit the Boost profile settings, proceed as
follows:
1. Open
Boost
profile main view.
2. Press the
Profile information
button.
3. Press the
Edit
button.
4. The fan speed setup opens.
5. Set the Boost profile fan speed as a percentage of the
maximum by using the
Plus
and
Minus
buttons.
6. Press the
Right arrow
button.
7. The temperature setup screen is opened.
8. Set the desired supply air temperature for the
Boost
profile
by using the
Plus
and
Minus
buttons. The recommended
temperature is +15°C or 2—3°C below the room temperature.
You can adjust the temperature in the range of +10°C – +5°C.
9. Press the
Right arrow
button.
10. The setup screen for the automatic fan speed control, based
on the relative humidity, appears.
11. Use the
Plus
and
Minus
buttons to select whether the
automatic fan speed control, based on the relative humidity, is
used or not.
12. Press the
Right arrow
button.
13. The setup for automatic fan speed control based on the
carbon dioxide or VOC level opens.
14. Use the
Plus
and
Minus
buttons to select whether the
automatic fan speed control, based on the carbon dioxide or
VOC level, is used or not.
15. Press the
Right arrow
button.
16. The profile timer setting screen is opened.
17. Use the
Plus
and
Minus
buttons to select whether the profile
timer function is used or not. The options are:
• On
— When the timer is on, the
Boost
profile is used only
for the period specified in the timer.
• Off
— When the timer is off, the
Boost
profile is used until
manually changed (or the Week clock) change the profile.
18. Press the
Right arrow
button.
19. The profile timer duration setting screen is opened.
20. Set the profile timer duration by using the
Plus
and
Minus
buttons.
21. Press the
OK
button.