15
© Airflow • We reserve the right to make changes without prior notice
DV50 DV80
(Integral CO
2
Sensor)
EXPERT SETTINGS
DEPLOYMENT WIZARD
BOOST PROFILE
When you want to set the
Boost
profile settings, proceed as
follows:
1. The deployment wizard
Boost
profile screen is opened.
NOTE
Once you have set the fan speed for the
At home
profile, the fan
speed for the
Boost
profile will default to +30% of the At home
profile fan speed. We recommend this basic amount of ventilation
for the
Boost
profile setting. If necessary, you can change it.
2. Set the
Boost
profile fan speed as a percentage of the
maximum by using the
Plus
and
Minus
buttons.
3. Press the
Right arrow
button.
4. The temperature setup screen is opened.
5. Set the desired supply air temperature for the
Boost
profile
by using the
Plus
and
Minus
buttons. You can adjust the
temperature in the range of +10°C – +5°C.
6. Press the
Right arrow
button.
7. The setup screen for the automatic fan speed control, based on
the relative humidity, appears.
8. Use the
Plus
and
Minus
buttons to select whether the
automatic fan speed control, based on the relative humidity, is
used or not.
9. Press the
Right arrow
button.
10. The setup screen for the automatic fan speed control, based on
the carbon dioxide or VOC content, appears.
11. Use the
Plus
and
Minus
buttons to select whether the
automatic fan speed control, based on the carbon dioxide or
VOC content, is used or not.
12. Press the
Right arrow
button.
13. The profile timer setting screen is displayed.
14. Use the
Plus
and
Minus
buttons to select whether the profile
timer function is enabled or not. The options are:
•
On
— When the timer is enabled, the
Boost
profile is
only on for the period defined in the timer.
•
Off
— When the timer is disabled, the
Boost
profile is
used until you (or the week clock) change the profile.
15. Press the
Right arrow
button.
16. The timer duration setting screen appears.
17. Set the profile timer duration in minutes by using the
Plus
and
Minus
buttons.