DEPLOYMENT WIZARD
EXPERT SETTINGS
PROFILE SETTINGS
In the following chapters, you can make ventilation settings for the
system profiles.
AT HOME PROFILE
When you want to set the
At home
profile settings, proceed as
follows:
1. The deployment wizard
At home
screen will open.
NOTE
When the units fans have been set (step 5 in the deployment
wizard) these values will default to the
At home
profile fan speed
value. We recommend this basic amount of ventilation for the
At
home
profile setting. If necessary, you can change it.
2. Set the
At Home
profile fan speed as a percentage of the
maximum by using the
Plus
and
Minus
buttons.
3. The
At Home
profile fan speed value is now set.
4. Press the
Right arrow
button.
5. The temperature setup screen is opened.
6. Set the desired supply air temperature for the
At Home
profile
by using the
Plus
and
Minus
buttons. You can adjust the
temperature in the range of +10°C – +5°C.
7. The At home profile supply air temperature is now set.
8. Press the
Right arrow
button.
9. The setup screen for the automatic fan speed control, based on
the relative humidity, appears.
10. Use the
Plus
and
Minus
buttons to select whether the
automatic fan speed control, based on the relative humidity, is
used or not.
11 The automatic fan speed control, based on the relative
humidity, is now set.
12. Press the
Right arrow
button.
13. The setup screen for the automatic fan speed control, based on
the carbon dioxide or VOC content, appears.
14. Use the
Plus
and
Minus
buttons to select whether the
automatic fan speed control, based on the carbon dioxide or
VOC content, is used or not.
15. The automatic fan speed control, based on the carbon dioxide
or VOC content, is now set.
16. Press the
OK
button.
NOTE
You can browse the settings of
the At home profile with the
Right
arrow
button.