CONDENSATE TRAP LOCATIONS
(Unit shown in horizontal right hand discharge position
)
Figure 45
*Piping from furnace must slope down a minimum
of 1/4” per ft. toward trap.
Figure 46
UNIT WITH EVAPORATOR COIL
Condensate line must slope downward away from the trap
to drain. If drain level is above condensate trap, condensate
pump must be used. Condensate drain line should be routed
within the conditioned space to avoid freezing of condensate
and blockage of drain line. If this is not possible, a heat
cable kit may be used on the condensate trap and line.
Heating cable kit is available in various lengths; 6 ft. (1.8 m)
- kit no. 26K68; 24 ft. (7.3 m) - kit no. 26K69; and 50 ft. (15.2
m) - kit no. 26K70.
Figure 44
CONDENSATE TRAP LOCATIONS
(Unit shown in upflow position with remote trap)
*Piping from furnace must slope down a minimum of 1/4”
per ft. toward trap.
Do not use copper tubing or existing copper condensate
lines for drain line.
CAUTION
A separate drain line must be run to the drain from the
condensate trap to ensure proper drainage and pressure
switch operation.
DO NOT
connect the condensate trap
drain into the drain line from the evaporator coil.
CAUTION
Summary of Contents for 95G2UHV
Page 3: ...506878 01 Page 3 of 62 Issue 1139 EXPANDED VIEW Figure 1 ...
Page 28: ...506878 01 Page 28 of 62 Issue 1139 Figure 31 FIELD SUPPLIED WALL TERMINATION ...
Page 29: ...506878 01 Page 29 of 62 Issue 1139 Figure 32 ...
Page 35: ...506878 01 Page 35 of 62 Issue 1139 Figure 47 TRAP DRAIN ASSEMBLY USING 1 2 PVC or 3 4 PVC ...
Page 46: ...506878 01 Page 46 of 62 Issue 1139 TYPICAL WIRING DIAGRAM Figure 56 ...
Page 60: ...506878 01 Page 60 of 62 Issue 1139 Start Up Performance Check List UNIT SET UP ...
Page 61: ...506878 01 Page 61 of 62 Issue 1139 UNIT OPERATION Heating Mode Cooling Mode ...