FIRE OR EXPLOSION HAZARD

Failure to follow safety warnings could result in injury, death,

or property damage.
Do not store or use gasoline or other flammable vapors and

liquids in the vicinity of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS

--Do not try to light any appliance.

--Do not touch any electrical switch; do not use any

phone in your building.

--Leave the building immediately.

--Immediately call your gas supplier from a near by phone.

Follow the gas supplier’s instructions.

--If you cannot reach your gas supplier, call the fire

department.

Installation and service must be performed by a qualified

installer, service agency or the gas supplier.

!

WARNING

CARBON MONOXIDE POISONING HAZARD

Failure to follow this warning could result in personal

injury and/or death.
Carbon Monoxide is invisible, odorless, and toxic! Bryant

Heating and Cooling Systems recommends a carbon

monoxide alarm in your home, even if you do not own a

gas appliance. Locate the carbon monoxide alarm in the

living area of your home and away from gas appliances and

doorways to attached garages. Follow the alarm

manufacturer’s instruction included with the alarm.

!

WARNING

ELECTRICAL OPERATION HAZARD

Failure to follow this warning could result in personal injury,

death, or property damage.
Do not use this furnace if any part has been under water. A

flood--damaged furnace is extremely dangerous. Attempts to

use the furnace can result in fire or explosion. A qualified

service agency should be contacted to inspect the furnace and

to replace all gas controls, control system parts, electrical parts

that have been wet or the furnace if deemed necessary.

!

WARNING

Summary of Contents for 311JAV Legacy Line Plus 80

Page 1: ...If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier WARNING CARBON MONOXIDE POISONING...

Page 2: ...T BE KEPT FREE AND CLEAR OF INSULATING MATERIAL WARNING 3 STARTING LIGHTING AND SHUTTING DOWN THE FURNACE WARNING 4 5 PROPER FURNACE SHUTDOWN PROCEDURES 5 SERVICE AND MAINTENANCE ELECTRICAL HAZARD WAR...

Page 3: ...u Request a Service Call section in this manual FIRE OR EXPLOSION HAZARD Failure to follow this safety warning could result in injury death or property damage Do not keep combustible materials gasolin...

Page 4: ...age Should the gas supply fail to shut off or if overheating occurs turn off the manual gas valve to the furnace BEFORE turning off the electrical supply and install lockout tag WARNING S CHECK AIR FI...

Page 5: ...stat the furnace will switch on automatically When the room temperature reaches the setting selected on the thermostat the furnace will be automatically switched off Continuous Fan Operation Some ther...

Page 6: ...can cause a loss of efficiency CAUTION A dirty filter will cause excessive stress on the furnace heat exchanger and blower motor and can cause it to overheat and automatically shut down The furnace f...

Page 7: ...If side return ducts are used 2 filters may be required in some models The procedure listed above may be used to remove side filters PERSONAL INJURY HAZARD Failure to follow this caution may result i...

Page 8: ...efore you call for service check for several easily solved problems S Check for sufficient airflow Check the air filter for dirt Check for blocked return air or supply air grilles Be sure they are ope...

Page 9: ...ing blower wheel and motor X Inspect gas valve and check for proper manifold gas pressure Adjust as needed X Inspect ignition system and safety controls Clean and adjust as needed X Inspect control bo...