24. ELECTRICAL POWER
24.00.00
General
The 582 Trike base has a 12V electrical system essentially comprising of a 12V battery, the Rotax
alternator and accessories. A detailed description and schematic are available in the pilots handbook,
section 7.13. The Rotax manual should be consulted for the maintenance of the engines electrical
system.
24.10.00
Maintenance
The maintenance of the electrical system should include periodic inspection of the wiring loom for
chafing and other damage through its entire length. Pay special attention to the areas that are subject
to possible wear points such as sharp corners or proximity to parts, which move. It should be noted that
the electrical wires may be subject to wear through vibration in flight.
Wiring that is damaged should be replaced and if any wear points are identified then a product such as
spiral wrap should be used to cover the area. The advantage with the use of spiral wrap is that it allows
inspection of the wires even after it is installed.