10
Setting the A/D values
At this point, you have installed all of the QuickLoad system
components. You will next adjust the delection sensor to read
weight correctly by setting its A/D values. A/D refers to the analog-
to-digital conversion of the sensor reading.
This step will require the use of either the QuickLoad Scale or the
Delection Sensor Test box (P/N 1001). If using the QuickLoad
Scale, the scale must be installed and powered, and the Delection
Sensor Extension Cable must be installed.
Assembling the Electrical Connector
1.
To assemble the connectors, insert the delection sensor
connector plug into the sensor extension cable connector OR
connect to the delection sensor test box (P/N 1001). Ensure
the locking tabs on the connector plug engage completely.
Assembling the Electrical Connector
Note: When tightening the bolts, ALWAYS torque the nut, NOT the
bolt head. The bolt head should be in the bolt head holder, which is
built into the bracket.