background image

Software

Installation & Configuration 

Instructions

Panoramic X-ray System

Panoramic  Cephalometric  X-Ray System

S-Pan with Optional Stand Assembly Shown

S-Pan CEPH with Optional Stand Assembly Shown

Summary of Contents for ProVecta S-Pan

Page 1: ...Software Installation Configuration Instructions Panoramic X ray System Panoramic Cephalometric X Ray System S Pan with Optional Stand Assembly Shown S Pan CEPH with Optional Stand Assembly Shown...

Page 2: ......

Page 3: ...card still provides the connection to the office network 1 Setting up the ProVecta network Data transmission between ProVecta and PC is accom plished over a separate network connection made via a addi...

Page 4: ...s 5 From the Network Adapter group double click the Gigabit network connection for ProVecta Observe that the properties window for the network adapter opens 6 Select Power Management tab 7 Un check th...

Page 5: ...un the Setup program located in the root directory of the CD typically D AutoRun exe and select Install Software from the menu a Follow the on screen instructions to complete the software installation...

Page 6: ...he CrongIPC item from the Air Techniques ProVecta S Pan submenu 3 b With the Gigabit Ethernet card installed only for ProVecta S Pan operation selected Click the Set to CRONG client IP button and perf...

Page 7: ...If the Warning message displays click OK close the CRONGIPC application make sure the network adapter is properly seated and drivers loaded Also make sure that S Pan is turned on and physically conne...

Page 8: ...for the ProVecta S Pan without Ceph 4 c ProVecta S Pan with Ceph file download 1 Keep all six file check boxes selected 2 Click Download 3 Observe the successful download progress of all six selected...

Page 9: ...the Activate VistaEasyView check box is unchecked as shown 5 e Click the Configuration ScanX Ray icon 5 f If any device is checked uncheck it and click the indicated Refresh symbol Then check only th...

Page 10: ...Air Techniques Inc Page 10 NOTES...

Page 11: ...on The imaging management software covered includes the following manufacturers Item Application Page 1 Apteryx XrayVision Version 3 12 12 2 Apteryx XrayVision Lite Version 3 12 14 3 Dexis 9 16 4 Dexi...

Page 12: ...t Patient from the top tool bar 6 1c Select Capture Single Image through either the File tab or the capture icon located on the top tool bar 6 1d Observe that the Image Capture window opens Choose the...

Page 13: ...OK tab Observe that a splash screen flashes briefly and the ProVecta S Pan image acquire window opens 6 1j Refer to the ProVecta S Pan Operating Instructions as necessary and acquire an im age 6 1k O...

Page 14: ...s 6 2b Select a patient an exiting one or newly created as necessary 6 2c Observe that the commands on the side bar are active Click the Take X ray command 6 2d Observe that the Take images for what t...

Page 15: ...TION SETUP 6 2g Select the ProVecta S Pan 8 Bit from the drop down menu and choose OK tab 6 2h Observe that the ProVecta S Pan image acquire window opens Refer to the ProVecta S Pan Operating Instruct...

Page 16: ...am Information window opens Click OK and observe that the Preferences window opens 6 3b Select the DEXray tab Select the ProVecta S Pan 16 Bit from the scanner drop down menu 6 3c Click Done and obser...

Page 17: ...ormation window opens Click OK and observe that the Preferences window opens 6 4b Select X ray Acquisition from the list on the left Select the ProVecta S Pan 16 Bit from the scanner drop down menu 6...

Page 18: ...ferences from the list which opens a new window as shown Select the following 1 Select X ray tab 2 Check use scanner default interface check box 3 Select Scanner tab 6 5c Observe that the Select Sourc...

Page 19: ...indow displays altering the user to restart the computer so the selected preferences will be incorporated Click the OK button to return to the main program window 6 5f From the main program window sel...

Page 20: ...window open a task list by selecting New Exam Select other Tem plate from the list and observe that an Image Template List pop up window displays 6 5j Scroll down the list to Panoramic and select the...

Page 21: ...6 5k Verify that Scanner is the default source selected on the Edit Image Template pop up window Click the OK button to return to the exam window 6 5l Select Panoramic as a template 6 5m Select Acquir...

Page 22: ...s At this point you must call for a module activation code and input the code to continue setup via Tigerview Administration window as shown 6 6d With the Tigerview Administration window displayed sel...

Page 23: ...s JPEG A new window opens for default acquisition mode options 6 6l Select the Photo Slide Scanning radio button 6 6m Clicking Finish to accept the selection opens a pop up query window 6 6n Click Yes...

Page 24: ...dule Configuration radio button from the list 6 7b Click Next and observe that the Module Configuration window opens 6 7c Install the Flatbed Scanner module and Click Next 6 7d Observe that the Visix...

Page 25: ...rop down list of operational functions 6 8b Select Optical Scanner Select from the list and observe that the Select Source window opens 6 8c Highlight ProVecta S Pan 16 Bit 1 40 32 32 from the source...

Page 26: ...sed in ProVecta S Pan image processing 7 1a Open the start menu and select the DDIPS item from the Air Techniques ProVecta S Pan menu 7 1b Observe that the DDIPS window opens 7 1c Press the Search but...

Page 27: ...pop up message appears and the software automatically generates the various preview levels 7 1g Observe that the preview of the generated levels of the selected RAW file displays There are 1 to 5 lev...

Page 28: ...the brightness control left brighter right darker as desired 7 1j Now click on the Simulation button to simulate the image with the new settings 7 1k Observe that the image is processed and another le...

Page 29: ...If the level S image is unsatisfactory click on the Initialization button and select YES from the pop up message window to delete the image 7 1n Once a desired level is found Level 1 5 or Level S it...

Page 30: ...to ZeusPano2_old ini 7 1r Then save the new file ZeusPano2 ini in the same folder All future ProVecta S Pan images will be processed using the filter settings of this new ZeusPano2 ini file 7 1p 7 1q...

Page 31: ...r image via the TWAIN third party application 7 2a Open the control window shown below by selecting image acquisition via the TWAIN third party application and select the Tools button 7 2b Select Tran...

Page 32: ...MicroDicom item from the Air Techniques ProVecta S Pan menu 7 3b On the MicroDicom window select Open from the from the FILE drop down menu 7 3c Navigate to C ProgramData Air Techniques Images and se...

Page 33: ...ect Export To picture file from the from the FILE drop down menu 7 3f Observe that the Export to Images pop up window opens Input the destination path where the recovered file will be saved or parked...

Page 34: ...s window opens Click the appropriate Local Area Connection and select Properties from the resulting pop up window 7 4d From the Local Area Connection Properties window select the Internet Protocol TCP...

Page 35: ...Page 35 Air Techniques Inc Properties Internet Protocol OK Button Properties Button IP address 10 42 43 15 Subnet 255 255 255 0 ADVANCED PROCEDURES 7 4c 7 4d 7 4e...

Page 36: ...ake their practices to the next level Air Techniques family of quality products for the dental professional include Air Techniques Inc Copyright 2015 P N A7371 Rev E December 2017 Corporate Headquarte...