Air Live SI-101 User Manual Download Page 2

Copyright  and  Disclaimer 

i                                       

AirLive SI-101 User Manual

                                             

 

 

 

 

 

Copyright & Disclaimer 
 

No part of this publication may be reproduced in any form or by any means, whether 
electronic, mechanical, photocopying, or recording without the written consent of OvisLink 
Corp.   
 
OvisLink Corp. has made the best effort to ensure the accuracy of the information in this 
user’s guide.    However, we are not liable for the inaccuracies or errors in this guide.   
Please use with caution.    All information is subject to change without notice 
 
This product contains some codes from GPL. In compliance with GPL agreement, AirLive 
will publish the GPL codes on our website. Please go to www.airlive.com and go to the 
"Support->GPL" menu to download source code. 
 
All Trademarks are properties of their respective holders. 
 

Summary of Contents for SI-101

Page 1: ...SI 101 3 in 1 Multi sensor User Manual...

Page 2: ...ffort to ensure the accuracy of the information in this user s guide However we are not liable for the inaccuracies or errors in this guide Please use with caution All information is subject to change...

Page 3: ...et on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help This device complies with Part 15 of the FCC Rules Operation is...

Page 4: ...3 1 3 Z WaveTM Message Report 3 1 4 Power Up Procedure 5 1 5 Over The Air OTA Firmware Update 6 1 6 Security Network 6 1 7 Function DIP Switch 6 1 8 Operation Mode 7 1 9 Battery Installation 8 1 10 Ch...

Page 5: ......

Page 6: ...The technology uses a low power RF radio embedded or retrofitted into home electronics devices and systems such as lighting home access control entertainment systems and household appliances This pro...

Page 7: ...command from Z WaveTM controller about 20 seconds Remove 1 Have Z WaveTM Controller entered exclusion mode 2 Pressing tamper key three times within 1 5 seconds to enter the exclusion mode Node ID has...

Page 8: ...ey once The device will wake up 10 seconds 1 3 Z WaveTM Message Report When the door windows triggered the device will report the trigger event and also report the battery status temperature and illum...

Page 9: ...ahrenheit 60 degree Celsius the device will always report in each measurement 1 3 4 Illumination Report When the door window state changed the device will unsolicited to send the Sensor Multilevel Rep...

Page 10: ...NO 20 could change the tick interval the default value is 30 if setting to 1 that means the minimum auto report interval will be one minute And please notice if setting this value to zero that means d...

Page 11: ...and then re install the battery 1 6 Security Network The device supports the security function When the device included with a security controller the device will auto switch to the security mode In...

Page 12: ...messages also include the battery level the temperature and the illumination level The user can switch the report by setting the configuration NO 5 bit4 illumination and bit5 temperature and the conf...

Page 13: ...The battery type is CR123A 3 0V The way to open the front cover please follow below steps 1 Using a tool to press the 1 1 position to release the cover 2 Hold the front cover and pull back 3 Hold the...

Page 14: ...rk Wide Inclusion mode And it should be included in 5 seconds You will see the LED light ON one second 2 Let the controller associate with the device into the first group any light switch that intend...

Page 15: ...C command value to turn on the light The 0xFF 1 means turn on the light For dimmer equipment 1 to 100 means the light strength 0 means turn off the light 4 Light Threshold 99 0 100 Setting the illumin...

Page 16: ...ntrol 0 Bit0 Disable magnetic integrate illumination to turn ON the lighting nodes in the association group 2 1 Disable 0 Enable 0 Bit4 Disable delay 5 seconds to turn off the light when door window c...

Page 17: ...ration No 20 13 Auto Report Temperature Time 12 0 127 The interval time for auto report the temperature 0 means turn off auto report temperature The default value is 12 The tick time can setting by th...

Page 18: ...R_MULTILEVEL_V5 COMMAND_CLASS_WAKE_UP_V2 COMMAND_CLASS_ASSOCIATION_GRP_INFO COMMAND_CLASS_POWERLEVEL COMMAND_CLASS_DEVICE_RESET_LOCALLY COMMAND_CLASS_MULTI_CMD COMMAND_CLASS_SECURITY COMMAND_CLASS_FIR...