![Air Live SI-101 User Manual Download Page 15](http://html1.mh-extra.com/html/air-live/si-101/si-101_user-manual_2875064015.webp)
1. Overview
AirLive SI-101 User Manual
10
After finish the test and decide to fix, then you can remove tape A, and mounting the sensor
by using tape B. The tamper key will pressed and let the sensor enter normal mode.
1.12 Z-Wave Configuration Settings
Notice:
All of the configuration, the data size is 1.
The configuration mark with star(*), means after the remove the setting still keep, don't
reset to fac
tory default. Unless the user execute the “RESET” procedure.
The reserve bit or not supported bit is allowed any value, but no effect.
NO. Name
Def.
Valid
Description
2
Basic Set Level
OxFF
All
Setting the BASIC command value to turn on
the light. The 0xFF(-1) means turn on the light.
For dimmer equipment 1 to 100 means the
light strength.
0 means turn off the light.
4
Light
Threshold
99
0~100
Setting the illumination threshold to turn on the
light. When the event triggered and the
environment illumination lower then the
threshold, the device will turn on the light.
0 means turn off illumination detected function.
And never turn on the light. 1 means darkest.
99
means brightest.
100
means turn off illumination detected
function. And always turn on the light.
Notice:
In none test mode, only the value in 1 to
99 will enable the illumination detected function
and update the illumination value.
5(*)
Operation
Mode
0
All
Operation mode. Using bit to control.
Caution: The value is unsigned byte, the range
is from 0x00 ~ 0xFF.