1. Overview
AirLive SI-101 User Manual
7
1.8 Operation Mode
There are two modes “Test” and “Normal”.
“Test Mode” is for the user test the sensor function when installation.
“Normal Mode” for the normal operation.
When the event triggered, normally the LED won't indicated, unless the battery is in the low
level, the LED will flash once. But in the “Test Mode” the LED also will light ON one second.
When the event triggered, the device will report the messages to the nodes in the group 1.
The messages also include the battery level, the temperature and the illumination level.
The user can switch the report by setting the configuration NO. 5 bit4 (illumination) and bit5
(temperature), and the configuration NO. 7 bit6 (battery).
When the event triggered, if the environment luminance is less than the setting of the value
of the configuration NO. 4, the device will emit the signal to turn ON the lighting equipment,
those nodes are in the group 2. And delay a while to turn OFF the lighting equipment. The
delay time is setting by the configuration NO. 9.
Notice
: When the tamper key of the back side is released, the device always in the “Test Mode”, no
matter the DIP switches setting.