1. Overview
AirLive SI-101 User Manual
12
127
seconds).
0 means never send turn off light command.
10
Auto Report
Battery Time
12
0 ~
127
The interval time for auto report the battery
level.
0 means turn off auto report battery. The default
value is 12. The tick time can setting by the
configuration No.20.
11
Auto
Report
Door/Windo w
State
12
0 ~
127
The interval time for auto report the
door/window state.
0 means turn off auto report door/window state.
The default value is 12. The tick time can
setting by the configuration No.20.
12
Auto
Report
Illumination
Time
12
0 ~
127
The interval time for auto report the
illumination.
0 means turn off auto report
illumination.
The default value is 12. The tick time can setting
by the configuration No.20.
13
Auto
Report
Temperature
Time
12
0 ~
127
The interval time for auto report the
temperature.
0 means turn off auto report
temperature.
The default value is 12. The tick time can setting
by the configuration No.20.
20
Auto
Report
Tick Interval
30
0 ~
0xFF
The interval time for auto report each tick.
Setting this configuration will effect
configuration No.10, No.11, No.12 and No.13.
Caution
: Setting to
0
means turn off all auto
report function.
21
Temperature
Differential
Report
1
0 ~
0x7F
The temperature differential to report. 0 means
turn off this function.
The unit is Fahrenheit.
Enable this function the device will detect
every minute.
And when the temperature is over 140 degree
Fahrenheit, it will continue report.
Enable this functionality will cause some issue
please see the detail in the
“Temperature Report”
section.
22
Illumination
0
0 ~
0x63
The illumination differential to report.
0 means turn off this function.