9
General Description
IMPORTANT
Design and specifications are subject to change without notice
The Wine Guardian cooling unit is a professional grade, American-manufactured, split two-piece
climate control unit designed specifically for the storage of wine at cellar temperatures. It is designed
for easy installation and operation. Wine Guardian uses digital electronic controls and R-134a
refrigerant. The entire Wine Guardian fan coil section and the condensing unit is tested at the factory.
All components are of a high quality standard commercial grade.
The entire system is approved by ETL according to UL 1995 and CSA safety standards. All wiring
complies with NEC. Each Wine Guardian fan coil section is furnished with a sealed, UL-approved
power cord and plug.
All Wine Guardian 50Hz units carry the CE mark. Each unit is furnished with a sealed, CE- approved power
cord.
The Wine Guardian Ducted Split System Contains
1.
A Wine Guardian Fan Coil Unit with
:
✓
A thermal expansion valve to control the flow of refrigerant into the evaporator coil
✓
A built-in condensate drain trap. No external trap is required.
✓
A removable control panel for ease of service
✓
Supply duct collar
✓
Return duct collar
✓
Remote interface controller and control cable
2.
A Condensing Unit with
:
✓
A filter dryer to keep the refrigerant clean and free of contaminants
✓
A sight glass to observe the level of refrigerant
✓
A manual reset high pressure switch on the discharge to protect the compressor from high
pressures.
✓
Auto reset low pressure switch
✓
24-volt contactor for control of fan coil unit
✓
Outdoor enclosure
✓
Crankcase heater
✓
Low ambient refrigeration controls (see page 11 for Xtreme Low Ambient option)
Summary of Contents for 99H0360-10
Page 12: ...12 Xtreme Low Ambient Illustrations Fig 1 Fig 2 Pressure cutout timer 33c0185 00...
Page 14: ...14 Condensing unit dimensions DS050 COND NO OPTIONS...
Page 15: ...15 Refrigeration Illustration of the system See next page for magnified image...
Page 16: ...16 Magnified Image of the Condensing Unit...
Page 17: ...17 Wiring Diagram for DS025 DS050 WGS40 WGS75...
Page 18: ...18 Wiring Diagram for DS088 and WGS100...
Page 19: ...19 Wiring Diagram for DS200 and WGS175 Units...
Page 20: ...20 Wiring Diagram for Replacement Fan Motor XR 115 230 Models...
Page 21: ...21 Wiring Diagram for DS025 and WGS40 Condensing Unit...
Page 22: ...22 Wiring Diagram for DS050 and WGS75 Condensing Unit...
Page 23: ...23 Wiring Diagram for DS088 and WGS100 Condensing Unit...
Page 24: ...24 Wiring Diagram for DS200 and WGS175 Condensing Unit...
Page 25: ...25 Ducted Split Systems Specifications 60Hz Models DS025 DS050 DS088 DS200...
Page 26: ...26 Ducted Split System Specifications 50 Hz Models WGS40 WGS75 WGS100 WGS175...
Page 44: ...44 Install refrigeration piping per local codes and ASHRAE guidelines...