57
Mounting the Remote Interface Controller (Wireless)
Fig. 1
Fig. 2
Fig. 3
Fig. 4
1. Disconnect the controller wire from the side of the Wine
Guardian unit and save for future use.
2. Plan on mounting the remote interface controller on a
solid surface away from doors, corners, air outlets, drafts
or heat generating equipment. Do not mount the remote
interface controller directly on an outside wall, a wall
adjacent to a boiler room, or other hot area. Use a piece
of foam insulation behind the sensor to insulate it from a
hot or cold surface. The recommended height is four to
five feet above the finished floor.
3. Unscrew and remove the back plate from the Remote
Interface Controller (Fig. 1)
4. Place the back plate against the wall and mark the
mounting points at the desired location. (Fig. 2)
5. Drill two one-eighth inch holes and insert anchors within
the mounting surface. Anchors may not be required if
securing to a wall stud or racking system. Insert the
screws into the holes and test fit the backing plate for
mounting to ensure it mounts easily onto the two screws
and slides down onto the slotted openings freely (Fig. 3)
6. Reattached the back plate to the Remote Interface
Controller. (Fig. 4)
7. Insert the three AA batteries.
(only applicable with wireless installations)
8. The system will automatically acknowledge a wireless
device (Remote Interface or Remote Sensor). Go to
Setting “30” to define the Remote User Interface use.
9. Attach controller to the wall.
Summary of Contents for 99H0360-10
Page 12: ...12 Xtreme Low Ambient Illustrations Fig 1 Fig 2 Pressure cutout timer 33c0185 00...
Page 14: ...14 Condensing unit dimensions DS050 COND NO OPTIONS...
Page 15: ...15 Refrigeration Illustration of the system See next page for magnified image...
Page 16: ...16 Magnified Image of the Condensing Unit...
Page 17: ...17 Wiring Diagram for DS025 DS050 WGS40 WGS75...
Page 18: ...18 Wiring Diagram for DS088 and WGS100...
Page 19: ...19 Wiring Diagram for DS200 and WGS175 Units...
Page 20: ...20 Wiring Diagram for Replacement Fan Motor XR 115 230 Models...
Page 21: ...21 Wiring Diagram for DS025 and WGS40 Condensing Unit...
Page 22: ...22 Wiring Diagram for DS050 and WGS75 Condensing Unit...
Page 23: ...23 Wiring Diagram for DS088 and WGS100 Condensing Unit...
Page 24: ...24 Wiring Diagram for DS200 and WGS175 Condensing Unit...
Page 25: ...25 Ducted Split Systems Specifications 60Hz Models DS025 DS050 DS088 DS200...
Page 26: ...26 Ducted Split System Specifications 50 Hz Models WGS40 WGS75 WGS100 WGS175...
Page 44: ...44 Install refrigeration piping per local codes and ASHRAE guidelines...