NOTE:
Check
each
separately,
one
or
the
other
port
must
be
open
during
this
test.
Use
0
‐
100
PSI
pressure
gauge
and
0
‐
30
inch
Hg
vacuum
gauge,
(or
mercury
manometer.)
Troubleshooting
This
section
lists
common
problems
that
occur,
possible
causes
and
the
most
common
fixes.
If
the
problem
persists,
the
pump
may
require
inspection
at
the
ADI
facility.
To
have
your
pump
inspected
and
repaired
at
the
ADI
facility
please
follow
the
instructions
on
the
ADI
website
located
at
http://www.airdimensions.com/service/rma/
.
Eccentric
R27x
27
(22)
R25x
25
(21)
R22x
26
(22)
R20x
22
(18)
R18x
19
(16)
R15x
17
(14)
R12x
14
(12)
R10x
12
(10)
R08x
11
(9)
R06x
8
(7)
7
15
13
11
21.5
20
17
7
4
24
23.5
23
17
13
8
46
36
27
Minimum
LPM
Minimum
In Hg
60
52
Minimum Performance Requirements
Max Press
Open Flow
Ult Vac
Minimum
PSIG
Standard Product 60Hz
(50 Hz)