3-29
Chapter 3: INSTALLATION & WIRING
4.4. IP Station Connection
4.4.1. AN-8500MS connections
AN-8500MS rear
To network
To PC
To AC mains
To external speaker
DC INPUT EXT.SP. HEAD
PC
LAN
SET
12V
400mA
1
2
3
4
1. AC adapter terminal connection
Connect the AC adapter*.
Install the supplied ferrite clamp on the AC
adapter cable by winding the cable around the
ferrite clamp once.
* Use the AC adapter AD-1210P (optional) or the
equivalent.
As for the usable adapter, consult your
AIPHONE sales office.
2. External speaker terminal connection
3. Network connection terminal connection
Can be connected to a network of 10BASE-
T/100BASE-TX in auto-sensing.
Connecting the station to a PoE (Power over
Ethernet) switching hub compliant with
IEEE802.3af eliminates the need for an AC
adapter. (For connection, refer to the instruction
manual supplied with the switching hub.)
Use a UTP category 5 straight-through cable with
an RJ-45 connector for this connection.
4. PC connection terminal connection
A PC can be cascaded with the station. If power is
not supplied to the station, hub function will not
work.
Use a UTP category 5 straight-through cable with
an RJ-45 connector for this connection.
Cable
Ferrite clamp
(supplied with the AN-8500MS)
11 mm
COM
HOT
Press down the desired push-in
terminal button with a tip of standard
driver, and insert the cable securely.
For the type of cables, refer
to
INT.
SP
EXT.
SP
Note
When using the external speaker,
set the internal/external speaker
switch on the bottom to the EXT.
SP position.
Summary of Contents for AN-8000EX