3-25
Chapter 3: INSTALLATION & WIRING
COM
C
9
8
7
AN-8031MS rear
7
8
9
C
COM
External dial input terminal
Press down.
Cable
External dial input terminal block
8 mm
LINE H C
Open collector output: 30 V DC, 50 mA
External
power supply
Relay
Diode
To AN-8000EX Exchange
+24 VDC
GND
+
-
AN-8050DS (Rear panel)
4.2.4. AN-8031MS and external switch connections
External switches such as footswitches can be connected to the AN-8031MS's external dial input terminal.
Note
The cable length from the external switch should not exceed 3 m.
[Connections]
Turning on each switch connected to the terminal [7], [8], [9], or [C] permits the same operation as performed
by pressing the dial [7], [8], [9], or [C].
For example, the pre-programmed station numbers can be called by pressing the foot switch if one-touch
dialing is programmed into these dials.
Refer to
4.2.5. AN-8050DS and external relay connections
An external relay can be connected to the AN-8050DS's external output terminals. (Refer to
"Terminal
plug connection."
These contact outputs can be momentarily shorted by the operation from the conversation party's master
station.