80
Chapter 6. RAID Configuration
Locate Disk Drives in a Volume
Locate disk drives by flashing their LEDs.
Procedure
Step 1: Select the controller on the Adapter List window and press
Enter.
Step 2: Highlight SAS Topology and press
Enter
. The SAS Topology window will appear.
Step 3: Select the disk in the Device Identifier column and press
Enter
. The LED on the disk
will flash until you press a key to stop it.
Step 4: To identify all the disk drives in a volume, select the volume in the left column of the
SAS Topology window and press
Enter
. The LEDs flash on all disk drives in the
volume until you press a key to stop them.
Select a Boot Disk
Select a boot disk.
Procedure
Step 1: Select an adapter from the Adapter List.
Step 2: Select the SAS Topology option. If a device is currently designated as the boot
device, the Device Info column on the SAS Topology window lists the word Boot as
shown below.
Boot Device on SAS Topology Window page
If a device is currently designated as the alternative boot device, the Device Info
column shows the word Alt.
Step 3: Select the preferred boot disk and press
Alt + B
.
Step 4: Select the current boot disk and press
Alt + B
to remove the boot designator.
Step 5: Select the new boot disk and press
Alt + B
to change the boot disk.
Step 6: Select an alternative boot disk and press
Alt + A
.
Summary of Contents for SB401-VG
Page 1: ...UM_SB401 VG_v1 2_081921 SB401 VG Storage Barebone User s Manual...
Page 12: ...3 Chapter 1 Product Features 1 3 System Block Diagram...
Page 49: ...40 Chapter 3 Hardware Settings 3 3 1 Placement Top view Backside view 3 3 HDD Backplane 24 Bay...
Page 74: ...65 Chapter 5 BMC Configuration Settings Step 2 Input the IP address Set static IP...
Page 75: ...66 Chapter 5 BMC Configuration Settings Step 3 Input the subnet mask address...