15
2 conductor cable = Communication Wires
4 conductor cable = flow cell connections
8 conductor cable = power in, shifting valves and remote switch
When driving a Westfalia Surge gray shifting valve the Black + and Green + wires
should be hooked to the center terminal on the gray shifting valve. The white wire
hooks up to the milk line shutoff side of the valve and the red wire hooks to the
vacuum cylinder side of the valve. (The gray shifting valve uses a positive ground)
NOTICE
NOTICE
WHT
BLK
RED
GRN
BLU-
BR+
To Flow Cell (From
4
conductor flow cell cable)
Power In (from
8
conductor Cable)
WHT -
BLK+
RED -
GRN +
N/A
BLU
To Shut-off Valve
(
8
conductor
cable)
To Cylinder Valve
(
8
conductor
cable)
To
Communication
WHT
Internal Wiring MS-16 PCB
GRD
SD (Side)
Swing Parlor
(Prox Switch)
Orange
Yellow
Remote Start
Switch
Note: When Proximi-
ty Switches are used
(3 leads come from
the switch the power
lead must be connect-
ed to Power BR +